做肾腔内的全能体操运动员:四十年来 61 种柔性输尿管镜的光学和柔韧性特征趋势分析。

IF 2 2区 医学 Q2 UROLOGY & NEPHROLOGY
Ali Talyshinskii, B M Zeeshan Hameed, Nithesh Naik, Kinju Adhikari, Ulanbek Zhanbyrbekuly, Patrick Juliebø-Jones, Bhaskar Kumar Somani
{"title":"做肾腔内的全能体操运动员:四十年来 61 种柔性输尿管镜的光学和柔韧性特征趋势分析。","authors":"Ali Talyshinskii, B M Zeeshan Hameed, Nithesh Naik, Kinju Adhikari, Ulanbek Zhanbyrbekuly, Patrick Juliebø-Jones, Bhaskar Kumar Somani","doi":"10.1007/s00240-024-01591-2","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this review is to analyze the trend in optical features and flexibility changes of flexible ureteroscopes over the past decades, and determine the correlation of individual parameters with release period as well as with dimensional parameters. Flexible ureteroscopes mentioned in the literature or those commercially available were searched. To minimize the search bias, the instruments were grouped by release date time-periods of < 2000 year, 2000-2009, 2010-2019, and 2020 onwards. The final review included only those instrument models for which data on minimum and maximum depth of field, field of view, direction of view, and deflection degree had been determined. The correlation among features investigated as well as with release period was also determined. 61 models of flexible ureteroscopes (27 fibreoptic and 34 digital scopes) were included. Among the different features investigated among fiberoptic endoscopes, minimum depth of field positively and negatively correlated with channel size and field of view, respectively, whereas maximum depth of view and field of view positively correlated with overall shaft and deflection degree, respectively. Up and down deflection strongly correlated with each other and both were negatively proportional to the distal tip size. For the digital endoscopes, minimum depth of field negatively and positively correlated with distal tip size and working length, respectively. Maximum depth of field positively correlated with field of view, whereas the latter was negatively proportional to the overall shaft. As for the fiberoptic counterparts, up and down deflection strongly correlated with each other. Field of view, up and down deflection of fiberoptic flexible ureteroscopes, were significantly increased among fiberoptic and digital endoscopes over decades. As flexible ureteroscopy technology has evolved, there has been a trend towards increasing field of view with up and down deflection. Given the importance of scope ergonomics, one aspect of this popularity is the improvement of optical characteristics and deflection degree, which significantly correlates with the release period.</p>","PeriodicalId":23411,"journal":{"name":"Urolithiasis","volume":"52 1","pages":"92"},"PeriodicalIF":2.0000,"publicationDate":"2024-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Being all-seeing gymnast within kidney cavity: analysis of the optical and flexibility characteristics trends of 61 flexible ureteroscopes over four decades.\",\"authors\":\"Ali Talyshinskii, B M Zeeshan Hameed, Nithesh Naik, Kinju Adhikari, Ulanbek Zhanbyrbekuly, Patrick Juliebø-Jones, Bhaskar Kumar Somani\",\"doi\":\"10.1007/s00240-024-01591-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The purpose of this review is to analyze the trend in optical features and flexibility changes of flexible ureteroscopes over the past decades, and determine the correlation of individual parameters with release period as well as with dimensional parameters. Flexible ureteroscopes mentioned in the literature or those commercially available were searched. To minimize the search bias, the instruments were grouped by release date time-periods of < 2000 year, 2000-2009, 2010-2019, and 2020 onwards. The final review included only those instrument models for which data on minimum and maximum depth of field, field of view, direction of view, and deflection degree had been determined. The correlation among features investigated as well as with release period was also determined. 61 models of flexible ureteroscopes (27 fibreoptic and 34 digital scopes) were included. Among the different features investigated among fiberoptic endoscopes, minimum depth of field positively and negatively correlated with channel size and field of view, respectively, whereas maximum depth of view and field of view positively correlated with overall shaft and deflection degree, respectively. Up and down deflection strongly correlated with each other and both were negatively proportional to the distal tip size. For the digital endoscopes, minimum depth of field negatively and positively correlated with distal tip size and working length, respectively. Maximum depth of field positively correlated with field of view, whereas the latter was negatively proportional to the overall shaft. As for the fiberoptic counterparts, up and down deflection strongly correlated with each other. Field of view, up and down deflection of fiberoptic flexible ureteroscopes, were significantly increased among fiberoptic and digital endoscopes over decades. As flexible ureteroscopy technology has evolved, there has been a trend towards increasing field of view with up and down deflection. Given the importance of scope ergonomics, one aspect of this popularity is the improvement of optical characteristics and deflection degree, which significantly correlates with the release period.</p>\",\"PeriodicalId\":23411,\"journal\":{\"name\":\"Urolithiasis\",\"volume\":\"52 1\",\"pages\":\"92\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-06-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Urolithiasis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00240-024-01591-2\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Urolithiasis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00240-024-01591-2","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

本综述旨在分析过去几十年来柔性输尿管镜光学特性和灵活性的变化趋势,并确定个别参数与释放期以及尺寸参数的相关性。本文检索了文献中提到的或市场上有售的柔性输尿管镜。为尽量减少搜索偏差,将这些器械按发布日期的时间段分组为
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Being all-seeing gymnast within kidney cavity: analysis of the optical and flexibility characteristics trends of 61 flexible ureteroscopes over four decades.

Being all-seeing gymnast within kidney cavity: analysis of the optical and flexibility characteristics trends of 61 flexible ureteroscopes over four decades.

The purpose of this review is to analyze the trend in optical features and flexibility changes of flexible ureteroscopes over the past decades, and determine the correlation of individual parameters with release period as well as with dimensional parameters. Flexible ureteroscopes mentioned in the literature or those commercially available were searched. To minimize the search bias, the instruments were grouped by release date time-periods of < 2000 year, 2000-2009, 2010-2019, and 2020 onwards. The final review included only those instrument models for which data on minimum and maximum depth of field, field of view, direction of view, and deflection degree had been determined. The correlation among features investigated as well as with release period was also determined. 61 models of flexible ureteroscopes (27 fibreoptic and 34 digital scopes) were included. Among the different features investigated among fiberoptic endoscopes, minimum depth of field positively and negatively correlated with channel size and field of view, respectively, whereas maximum depth of view and field of view positively correlated with overall shaft and deflection degree, respectively. Up and down deflection strongly correlated with each other and both were negatively proportional to the distal tip size. For the digital endoscopes, minimum depth of field negatively and positively correlated with distal tip size and working length, respectively. Maximum depth of field positively correlated with field of view, whereas the latter was negatively proportional to the overall shaft. As for the fiberoptic counterparts, up and down deflection strongly correlated with each other. Field of view, up and down deflection of fiberoptic flexible ureteroscopes, were significantly increased among fiberoptic and digital endoscopes over decades. As flexible ureteroscopy technology has evolved, there has been a trend towards increasing field of view with up and down deflection. Given the importance of scope ergonomics, one aspect of this popularity is the improvement of optical characteristics and deflection degree, which significantly correlates with the release period.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Urolithiasis
Urolithiasis UROLOGY & NEPHROLOGY-
CiteScore
4.50
自引率
6.50%
发文量
74
期刊介绍: Official Journal of the International Urolithiasis Society The journal aims to publish original articles in the fields of clinical and experimental investigation only within the sphere of urolithiasis and its related areas of research. The journal covers all aspects of urolithiasis research including the diagnosis, epidemiology, pathogenesis, genetics, clinical biochemistry, open and non-invasive surgical intervention, nephrological investigation, chemistry and prophylaxis of the disorder. The Editor welcomes contributions on topics of interest to urologists, nephrologists, radiologists, clinical biochemists, epidemiologists, nutritionists, basic scientists and nurses working in that field. Contributions may be submitted as full-length articles or as rapid communications in the form of Letters to the Editor. Articles should be original and should contain important new findings from carefully conducted studies designed to produce statistically significant data. Please note that we no longer publish articles classified as Case Reports. Editorials and review articles may be published by invitation from the Editorial Board. All submissions are peer-reviewed. Through an electronic system for the submission and review of manuscripts, the Editor and Associate Editors aim to make publication accessible as quickly as possible to a large number of readers throughout the world.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信