使用 Pleth 变异指数作为 MitraClip 期间左心房压力变化的无创动态指标:经导管二尖瓣修复术。

IF 1.1 Q3 ANESTHESIOLOGY
Ashwin Vaidyanathan, Jayakar Guruswamy, Abhishek Saluja, Marvin Eng, Trevor Szymanski
{"title":"使用 Pleth 变异指数作为 MitraClip 期间左心房压力变化的无创动态指标:经导管二尖瓣修复术。","authors":"Ashwin Vaidyanathan, Jayakar Guruswamy, Abhishek Saluja, Marvin Eng, Trevor Szymanski","doi":"10.1177/10892532241260535","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Transcatheter edge-to-edge repair (TEER) with MitraClip is a safe and effective alternative to surgical mitral valve repair/replacement in patients with high operative risk. Pleth Variability Index (PVI) is a non-invasive, dynamic index based on analysis of the respiratory variations in the plethysmographic waveform recorded transcutaneously by the pulse oximeter.</p><p><strong>Objectives: </strong>The objective of the study was to evaluate if the hemodynamic effect of improved left-sided output after successful transcatheter mitral valve repair would lead to a significant change in PVI, and if it would correlate with the decrease in left atrial pressure (LAP).</p><p><strong>Design: </strong>Prospective, observational cohort study (ClinicalTrials.gov NCT03993938).</p><p><strong>Setting: </strong>Single academic hospital in Detroit, Michigan (USA), from October 2019 to February 2021.</p><p><strong>Participants: </strong>The authors included adult patients with severe mitral regurgitation who underwent successful MitraClip placement.</p><p><strong>Measurements and main results: </strong>Of 30 patients, all components of the LAP (<i>a</i> wave, <i>v</i> wave, and mean) decreased significantly after successful MitraClip placement (<i>P</i> < .01). The median (IQR) PVI increased from 21 (11-35) to 23 (13-38) after clip placement; however, this change was not statistically significant (<i>P</i> = .275). No significant correlation between change in PVI and change in LAP was observed (<i>P</i> = .235).</p><p><strong>Conclusions: </strong>In patients with severe mitral regurgitation, successful MitraClip resulted in a significant reduction in LAP without a significant change in PVI. A larger sample size may provide more insight on the utility of using PVI as an indicator of LAP change in patients with mitral regurgitation.</p>","PeriodicalId":46500,"journal":{"name":"Seminars in Cardiothoracic and Vascular Anesthesia","volume":" ","pages":"147-151"},"PeriodicalIF":1.1000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Use of Pleth Variability Index as a Non-invasive, Dynamic Indicator of Left Atrial Pressure Change During MitraClip: Transcatheter Mitral Valve Repair.\",\"authors\":\"Ashwin Vaidyanathan, Jayakar Guruswamy, Abhishek Saluja, Marvin Eng, Trevor Szymanski\",\"doi\":\"10.1177/10892532241260535\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Transcatheter edge-to-edge repair (TEER) with MitraClip is a safe and effective alternative to surgical mitral valve repair/replacement in patients with high operative risk. Pleth Variability Index (PVI) is a non-invasive, dynamic index based on analysis of the respiratory variations in the plethysmographic waveform recorded transcutaneously by the pulse oximeter.</p><p><strong>Objectives: </strong>The objective of the study was to evaluate if the hemodynamic effect of improved left-sided output after successful transcatheter mitral valve repair would lead to a significant change in PVI, and if it would correlate with the decrease in left atrial pressure (LAP).</p><p><strong>Design: </strong>Prospective, observational cohort study (ClinicalTrials.gov NCT03993938).</p><p><strong>Setting: </strong>Single academic hospital in Detroit, Michigan (USA), from October 2019 to February 2021.</p><p><strong>Participants: </strong>The authors included adult patients with severe mitral regurgitation who underwent successful MitraClip placement.</p><p><strong>Measurements and main results: </strong>Of 30 patients, all components of the LAP (<i>a</i> wave, <i>v</i> wave, and mean) decreased significantly after successful MitraClip placement (<i>P</i> < .01). The median (IQR) PVI increased from 21 (11-35) to 23 (13-38) after clip placement; however, this change was not statistically significant (<i>P</i> = .275). No significant correlation between change in PVI and change in LAP was observed (<i>P</i> = .235).</p><p><strong>Conclusions: </strong>In patients with severe mitral regurgitation, successful MitraClip resulted in a significant reduction in LAP without a significant change in PVI. A larger sample size may provide more insight on the utility of using PVI as an indicator of LAP change in patients with mitral regurgitation.</p>\",\"PeriodicalId\":46500,\"journal\":{\"name\":\"Seminars in Cardiothoracic and Vascular Anesthesia\",\"volume\":\" \",\"pages\":\"147-151\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Seminars in Cardiothoracic and Vascular Anesthesia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/10892532241260535\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/12 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Seminars in Cardiothoracic and Vascular Anesthesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/10892532241260535","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/12 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:对于手术风险较高的患者,使用MitraClip进行经导管边缘到边缘修补术(TEER)是手术二尖瓣修补/置换术的一种安全有效的替代方法。脉搏血氧饱和度变异指数(Pleth Variability Index,PVI)是一种非侵入性的动态指数,基于脉搏血氧饱和度仪经皮记录的脉搏血氧饱和度波形的呼吸变化分析:该研究的目的是评估经导管二尖瓣修复术成功后左心室输出量的改善是否会导致 PVI 发生显著变化,以及是否与左心房压(LAP)的降低相关:前瞻性观察队列研究(ClinicalTrials.gov NCT03993938):美国密歇根州底特律市的一家学术医院,时间为 2019 年 10 月至 2021 年 2 月:作者纳入了成功接受 MitraClip 置入术的严重二尖瓣反流成年患者:在 30 名患者中,成功置入 MitraClip 后 LAP 的所有成分(a 波、v 波和平均值)均显著下降(P < .01)。夹片置入后,PVI 的中位数(IQR)从 21(11-35)升至 23(13-38);但这一变化无统计学意义(P = .275)。PVI的变化与LAP的变化之间无明显相关性(P = .235):结论:在严重二尖瓣反流患者中,成功的 MitraClip 可显著降低 LAP,而 PVI 无明显变化。更大的样本量可能会让人更深入地了解将 PVI 作为二尖瓣反流患者 LAP 变化指标的实用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Use of Pleth Variability Index as a Non-invasive, Dynamic Indicator of Left Atrial Pressure Change During MitraClip: Transcatheter Mitral Valve Repair.

Background: Transcatheter edge-to-edge repair (TEER) with MitraClip is a safe and effective alternative to surgical mitral valve repair/replacement in patients with high operative risk. Pleth Variability Index (PVI) is a non-invasive, dynamic index based on analysis of the respiratory variations in the plethysmographic waveform recorded transcutaneously by the pulse oximeter.

Objectives: The objective of the study was to evaluate if the hemodynamic effect of improved left-sided output after successful transcatheter mitral valve repair would lead to a significant change in PVI, and if it would correlate with the decrease in left atrial pressure (LAP).

Design: Prospective, observational cohort study (ClinicalTrials.gov NCT03993938).

Setting: Single academic hospital in Detroit, Michigan (USA), from October 2019 to February 2021.

Participants: The authors included adult patients with severe mitral regurgitation who underwent successful MitraClip placement.

Measurements and main results: Of 30 patients, all components of the LAP (a wave, v wave, and mean) decreased significantly after successful MitraClip placement (P < .01). The median (IQR) PVI increased from 21 (11-35) to 23 (13-38) after clip placement; however, this change was not statistically significant (P = .275). No significant correlation between change in PVI and change in LAP was observed (P = .235).

Conclusions: In patients with severe mitral regurgitation, successful MitraClip resulted in a significant reduction in LAP without a significant change in PVI. A larger sample size may provide more insight on the utility of using PVI as an indicator of LAP change in patients with mitral regurgitation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.60
自引率
14.30%
发文量
31
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信