Lise N. Nielsen, Mette B. Petersen, Nynne Capion, Jo F.-H. Lundsgaard, Asger L. Jensen
{"title":"牛血清淀粉样蛋白 A 自动免疫比浊测定法的性能。","authors":"Lise N. Nielsen, Mette B. Petersen, Nynne Capion, Jo F.-H. Lundsgaard, Asger L. Jensen","doi":"10.1111/vcp.13355","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Acute phase proteins are a group of vital constituents of the innate immune system, which may also serve as circulatory biomarkers of inflammation. The major acute phase protein serum amyloid A (SAA) is a reliable and sensitive biomarker in cows, allowing for rapid detection of inflammatory disease. A multispecies automated immunoturbidimetric assay (VET-SAA, Eiken) has been validated for horses, dogs, and cats, and it has been used to measure SAA concentrations in bovine samples.</p>\n </section>\n \n <section>\n \n <h3> Objectives</h3>\n \n <p>The aim of the present study was to perform an analytical validation of the VET-SAA immunoturbidometric assay based on monoclonal antihuman SAA antibodies for the measurement of SAA in clinical samples from cows.</p>\n </section>\n \n <section>\n \n <h3> Methods and Results</h3>\n \n <p>The validation included an assessment of imprecision, inaccuracy, and detection limit, as well as an evaluation of the overlap performance, using banked serum from healthy and sick cows with or without inflammatory disease. Intra- and interassay variation ranged from 0.91% to 2.9% and 2.5% to 5.8%, respectively. The assay was performed with acceptable accuracy within a clinically relevant range of SAA, although minor signs of inaccuracy were detected. Overlap performance was acceptable, with the VET-SAA assay able to differentiate between healthy cows and cows with inflammatory and noninflammatory conditions. The automated VET-SAA assay is considered acceptable for the measurement of SAA in cows.</p>\n </section>\n </div>","PeriodicalId":23593,"journal":{"name":"Veterinary clinical pathology","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-06-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/vcp.13355","citationCount":"0","resultStr":"{\"title\":\"Performance of an automated immunoturbidimetric assay for bovine serum amyloid A\",\"authors\":\"Lise N. Nielsen, Mette B. Petersen, Nynne Capion, Jo F.-H. Lundsgaard, Asger L. Jensen\",\"doi\":\"10.1111/vcp.13355\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>Acute phase proteins are a group of vital constituents of the innate immune system, which may also serve as circulatory biomarkers of inflammation. The major acute phase protein serum amyloid A (SAA) is a reliable and sensitive biomarker in cows, allowing for rapid detection of inflammatory disease. A multispecies automated immunoturbidimetric assay (VET-SAA, Eiken) has been validated for horses, dogs, and cats, and it has been used to measure SAA concentrations in bovine samples.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Objectives</h3>\\n \\n <p>The aim of the present study was to perform an analytical validation of the VET-SAA immunoturbidometric assay based on monoclonal antihuman SAA antibodies for the measurement of SAA in clinical samples from cows.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods and Results</h3>\\n \\n <p>The validation included an assessment of imprecision, inaccuracy, and detection limit, as well as an evaluation of the overlap performance, using banked serum from healthy and sick cows with or without inflammatory disease. Intra- and interassay variation ranged from 0.91% to 2.9% and 2.5% to 5.8%, respectively. The assay was performed with acceptable accuracy within a clinically relevant range of SAA, although minor signs of inaccuracy were detected. Overlap performance was acceptable, with the VET-SAA assay able to differentiate between healthy cows and cows with inflammatory and noninflammatory conditions. The automated VET-SAA assay is considered acceptable for the measurement of SAA in cows.</p>\\n </section>\\n </div>\",\"PeriodicalId\":23593,\"journal\":{\"name\":\"Veterinary clinical pathology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-06-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1111/vcp.13355\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Veterinary clinical pathology\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/vcp.13355\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary clinical pathology","FirstCategoryId":"97","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/vcp.13355","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
摘要
背景:急性期蛋白是先天性免疫系统的一组重要成分,也可作为炎症的循环生物标志物。主要的急性期蛋白血清淀粉样蛋白 A(SAA)是一种可靠而灵敏的奶牛生物标记物,可用于快速检测炎症性疾病。一种多物种自动免疫比浊测定法(VET-SAA,Eiken)已在马、狗和猫身上得到验证,并已用于测量牛样本中的 SAA 浓度:本研究旨在对基于单克隆抗人 SAA 抗体的 VET-SAA 免疫比浊测定法进行分析验证,以测定奶牛临床样本中的 SAA:验证包括对不精确度、不准确度和检测限的评估,以及对重叠性能的评估,使用的是健康和患病奶牛(无论是否患有炎症性疾病)的血清库。测定内和测定间的变异范围分别为 0.91% 至 2.9% 和 2.5% 至 5.8%。在 SAA 的临床相关范围内,该测定的准确度可以接受,但也发现了轻微的不准确迹象。VET-SAA 检测法能够区分健康奶牛、炎症奶牛和非炎症奶牛,其重叠性能是可以接受的。自动 VET-SAA 检测法可用于测量奶牛的 SAA。
Performance of an automated immunoturbidimetric assay for bovine serum amyloid A
Background
Acute phase proteins are a group of vital constituents of the innate immune system, which may also serve as circulatory biomarkers of inflammation. The major acute phase protein serum amyloid A (SAA) is a reliable and sensitive biomarker in cows, allowing for rapid detection of inflammatory disease. A multispecies automated immunoturbidimetric assay (VET-SAA, Eiken) has been validated for horses, dogs, and cats, and it has been used to measure SAA concentrations in bovine samples.
Objectives
The aim of the present study was to perform an analytical validation of the VET-SAA immunoturbidometric assay based on monoclonal antihuman SAA antibodies for the measurement of SAA in clinical samples from cows.
Methods and Results
The validation included an assessment of imprecision, inaccuracy, and detection limit, as well as an evaluation of the overlap performance, using banked serum from healthy and sick cows with or without inflammatory disease. Intra- and interassay variation ranged from 0.91% to 2.9% and 2.5% to 5.8%, respectively. The assay was performed with acceptable accuracy within a clinically relevant range of SAA, although minor signs of inaccuracy were detected. Overlap performance was acceptable, with the VET-SAA assay able to differentiate between healthy cows and cows with inflammatory and noninflammatory conditions. The automated VET-SAA assay is considered acceptable for the measurement of SAA in cows.
期刊介绍:
Veterinary Clinical Pathology is the official journal of the American Society for Veterinary Clinical Pathology (ASVCP) and the European Society of Veterinary Clinical Pathology (ESVCP). The journal''s mission is to provide an international forum for communication and discussion of scientific investigations and new developments that advance the art and science of laboratory diagnosis in animals. Veterinary Clinical Pathology welcomes original experimental research and clinical contributions involving domestic, laboratory, avian, and wildlife species in the areas of hematology, hemostasis, immunopathology, clinical chemistry, cytopathology, surgical pathology, toxicology, endocrinology, laboratory and analytical techniques, instrumentation, quality assurance, and clinical pathology education.