外周血淋巴细胞免疫分型(TBNK)--BD FACSCanto II 和 BD FACSLyric 流式细胞仪的比较。

IF 1.5 4区 医学 Q4 IMMUNOLOGY
Central European Journal of Immunology Pub Date : 2024-01-01 Epub Date: 2024-03-05 DOI:10.5114/ceji.2024.135939
Aleksandra Wiśniewska, Julia Stańczyk, Urszula Demkow, Anna Stelmaszczyk-Emmel
{"title":"外周血淋巴细胞免疫分型(TBNK)--BD FACSCanto II 和 BD FACSLyric 流式细胞仪的比较。","authors":"Aleksandra Wiśniewska, Julia Stańczyk, Urszula Demkow, Anna Stelmaszczyk-Emmel","doi":"10.5114/ceji.2024.135939","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Flow cytometry immunophenotyping is a common laboratory technique for evaluating lymphocyte subpopulations. Its result remains an important diagnostic tool in various medical fields. Cytometric tests are performed in many laboratories, making the comparability between different devices using the same method an important aspect. We aimed to compare the results of lymphocyte immunophenotyping (lymphocytes B, T, Th and Tc, NK cells) between two different flow cytometers.</p><p><strong>Material and methods: </strong>The study included 93 patients of the Children's Teaching Hospital of the Medical University of Warsaw and 9 Multi-Check control results. The method of lymphocyte subpopulation assessment was based on fluorescent flow cytometry immunophenotyping, using a BD Multitest 6-color TBNK kit (Becton Dickinson). We compared BD FACSCanto II and BD FACSLyric analysers (Becton Dickinson). For data analysis, we used Spearman's rank correlation, Bland-Altman plot and Passing-Bablok regression.</p><p><strong>Results: </strong>Spearman's rank correlation showed a strong interrelation for all analysed parameters (0.808-0.985). In the Passing-Bablok regression analysis, all examined parameters showed linear dependence with the slope values close to 1 (0.940-1.134). Bland-Altman coefficient values were within the range of 2.94-8.62% with half of them being above 5% (T, Tc, Th, B, NKT absolute values and B percentage values).</p><p><strong>Conclusions: </strong>The results from both cytometers can be considered equivalent, but it should be noted that one of the statistical methods showed some deviations, presumably primarily due to the evaluators' different gating techniques. The training of specialists performing these tests requires more attention.</p>","PeriodicalId":9694,"journal":{"name":"Central European Journal of Immunology","volume":"49 1","pages":"45-51"},"PeriodicalIF":1.5000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11130988/pdf/","citationCount":"0","resultStr":"{\"title\":\"Peripheral blood lymphocyte immunophenotyping (TBNK) - a comparison of BD FACSCanto II and BD FACSLyric flow cytometry analysers.\",\"authors\":\"Aleksandra Wiśniewska, Julia Stańczyk, Urszula Demkow, Anna Stelmaszczyk-Emmel\",\"doi\":\"10.5114/ceji.2024.135939\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Flow cytometry immunophenotyping is a common laboratory technique for evaluating lymphocyte subpopulations. Its result remains an important diagnostic tool in various medical fields. Cytometric tests are performed in many laboratories, making the comparability between different devices using the same method an important aspect. We aimed to compare the results of lymphocyte immunophenotyping (lymphocytes B, T, Th and Tc, NK cells) between two different flow cytometers.</p><p><strong>Material and methods: </strong>The study included 93 patients of the Children's Teaching Hospital of the Medical University of Warsaw and 9 Multi-Check control results. The method of lymphocyte subpopulation assessment was based on fluorescent flow cytometry immunophenotyping, using a BD Multitest 6-color TBNK kit (Becton Dickinson). We compared BD FACSCanto II and BD FACSLyric analysers (Becton Dickinson). For data analysis, we used Spearman's rank correlation, Bland-Altman plot and Passing-Bablok regression.</p><p><strong>Results: </strong>Spearman's rank correlation showed a strong interrelation for all analysed parameters (0.808-0.985). In the Passing-Bablok regression analysis, all examined parameters showed linear dependence with the slope values close to 1 (0.940-1.134). Bland-Altman coefficient values were within the range of 2.94-8.62% with half of them being above 5% (T, Tc, Th, B, NKT absolute values and B percentage values).</p><p><strong>Conclusions: </strong>The results from both cytometers can be considered equivalent, but it should be noted that one of the statistical methods showed some deviations, presumably primarily due to the evaluators' different gating techniques. The training of specialists performing these tests requires more attention.</p>\",\"PeriodicalId\":9694,\"journal\":{\"name\":\"Central European Journal of Immunology\",\"volume\":\"49 1\",\"pages\":\"45-51\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11130988/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Central European Journal of Immunology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5114/ceji.2024.135939\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/5 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"IMMUNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Central European Journal of Immunology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5114/ceji.2024.135939","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/5 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"IMMUNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

导言流式细胞术免疫分型是一种评估淋巴细胞亚群的常用实验室技术。其结果仍是各医学领域的重要诊断工具。许多实验室都会进行流式细胞仪检测,因此使用相同方法的不同设备之间的可比性是一个重要方面。我们旨在比较两种不同流式细胞仪的淋巴细胞免疫分型(淋巴细胞 B、T、Th 和 Tc、NK 细胞)结果:研究包括华沙医科大学儿童教学医院的 93 名患者和 9 个多重检查对照结果。淋巴细胞亚群评估方法基于荧光流式细胞仪免疫分型,使用的是 BD Multitest 6 色 TBNK 试剂盒(Becton Dickinson)。我们比较了 BD FACSCanto II 和 BD FACSLyric 分析仪(Becton Dickinson)。在数据分析中,我们使用了斯皮尔曼等级相关性、Bland-Altman图和Passing-Bablok回归法:结果:斯皮尔曼等级相关性表明,所有分析参数都有很强的相关性(0.808-0.985)。在 Passing-Bablok 回归分析中,所有检测参数均呈线性相关,斜率值接近 1(0.940-1.134)。Bland-Altman系数值在2.94%-8.62%之间,其中一半高于5%(T、Tc、Th、B、NKT绝对值和B百分比值):两种细胞计数器得出的结果可以说是等效的,但需要注意的是,其中一种统计方法出现了一些偏差,这可能主要是由于评估人员的门控技术不同造成的。对进行这些测试的专家的培训需要更多关注。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Peripheral blood lymphocyte immunophenotyping (TBNK) - a comparison of BD FACSCanto II and BD FACSLyric flow cytometry analysers.

Introduction: Flow cytometry immunophenotyping is a common laboratory technique for evaluating lymphocyte subpopulations. Its result remains an important diagnostic tool in various medical fields. Cytometric tests are performed in many laboratories, making the comparability between different devices using the same method an important aspect. We aimed to compare the results of lymphocyte immunophenotyping (lymphocytes B, T, Th and Tc, NK cells) between two different flow cytometers.

Material and methods: The study included 93 patients of the Children's Teaching Hospital of the Medical University of Warsaw and 9 Multi-Check control results. The method of lymphocyte subpopulation assessment was based on fluorescent flow cytometry immunophenotyping, using a BD Multitest 6-color TBNK kit (Becton Dickinson). We compared BD FACSCanto II and BD FACSLyric analysers (Becton Dickinson). For data analysis, we used Spearman's rank correlation, Bland-Altman plot and Passing-Bablok regression.

Results: Spearman's rank correlation showed a strong interrelation for all analysed parameters (0.808-0.985). In the Passing-Bablok regression analysis, all examined parameters showed linear dependence with the slope values close to 1 (0.940-1.134). Bland-Altman coefficient values were within the range of 2.94-8.62% with half of them being above 5% (T, Tc, Th, B, NKT absolute values and B percentage values).

Conclusions: The results from both cytometers can be considered equivalent, but it should be noted that one of the statistical methods showed some deviations, presumably primarily due to the evaluators' different gating techniques. The training of specialists performing these tests requires more attention.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.00
自引率
0.00%
发文量
17
审稿时长
6-12 weeks
期刊介绍: Central European Journal of Immunology is a English-language quarterly aimed mainly at immunologists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信