评估磁共振成像过程中双胎胎儿暴露于射频场的情况。

IF 0.8 4区 环境科学与生态学 Q4 ENVIRONMENTAL SCIENCES
Nan Zhong, Qunzheng Mi, Meng Lu, Haoyu Jiang, Yi Zhang
{"title":"评估磁共振成像过程中双胎胎儿暴露于射频场的情况。","authors":"Nan Zhong, Qunzheng Mi, Meng Lu, Haoyu Jiang, Yi Zhang","doi":"10.1093/rpd/ncae119","DOIUrl":null,"url":null,"abstract":"<p><p>Fetal development is essential to the human lifespan. As more and more multifetal gestations have been reported recently, clinical diagnosis using magnetic resonance imaging (MRI), which introduced radiofrequency (RF) exposure, raised public concerns. The present study developed two whole-body pregnant models of 31 and 32 gestational weeks (GWs) with twin fetuses and explored RF exposure by 1.5 and 3.0 T MRI. Differences in the relative position of the fetus and changes in fetal weight can cause differences in fetal peak local specific absorption rate averaged over 10 g tissue (pSAR10g). Variation of pSAR10g due to different fetal positions can be ~35%. Numerically, twin and singleton fetal pSAR10g results were not significantly different, however twin results exceeded the limit in some cases (e.g. fetuses of 31 GW at 1.5 T), which indicated the necessity for further research employing anatomically correct twin-fetal models coming from various GWs and particular sequence to be applied.</p>","PeriodicalId":20795,"journal":{"name":"Radiation protection dosimetry","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of twin fetal exposure to radiofrequency field during magnetic resonance imaging.\",\"authors\":\"Nan Zhong, Qunzheng Mi, Meng Lu, Haoyu Jiang, Yi Zhang\",\"doi\":\"10.1093/rpd/ncae119\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Fetal development is essential to the human lifespan. As more and more multifetal gestations have been reported recently, clinical diagnosis using magnetic resonance imaging (MRI), which introduced radiofrequency (RF) exposure, raised public concerns. The present study developed two whole-body pregnant models of 31 and 32 gestational weeks (GWs) with twin fetuses and explored RF exposure by 1.5 and 3.0 T MRI. Differences in the relative position of the fetus and changes in fetal weight can cause differences in fetal peak local specific absorption rate averaged over 10 g tissue (pSAR10g). Variation of pSAR10g due to different fetal positions can be ~35%. Numerically, twin and singleton fetal pSAR10g results were not significantly different, however twin results exceeded the limit in some cases (e.g. fetuses of 31 GW at 1.5 T), which indicated the necessity for further research employing anatomically correct twin-fetal models coming from various GWs and particular sequence to be applied.</p>\",\"PeriodicalId\":20795,\"journal\":{\"name\":\"Radiation protection dosimetry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-06-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiation protection dosimetry\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1093/rpd/ncae119\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation protection dosimetry","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1093/rpd/ncae119","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

胎儿发育对人类的寿命至关重要。随着近来越来越多的多胎妊娠报道,使用磁共振成像(MRI)进行的临床诊断引入了射频(RF)暴露,引起了公众的关注。本研究建立了两个分别为 31 和 32 孕周(GWs)的双胎全身妊娠模型,并通过 1.5 和 3.0 T 磁共振成像探究了射频暴露。胎儿相对位置的差异和胎儿体重的变化会导致胎儿平均 10 克组织的局部比吸收率峰值(pSAR10g)的差异。不同胎位导致的 pSAR10g 差异可达约 35%。从数值上看,双胎和单胎的 pSAR10g 结果差异不大,但在某些情况下(如 1.5 T 下 31 GW 的胎儿),双胎的 pSAR10g 结果超过了限值,这表明有必要采用来自不同 GW 和特定序列的解剖学上正确的双胎模型进行进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of twin fetal exposure to radiofrequency field during magnetic resonance imaging.

Fetal development is essential to the human lifespan. As more and more multifetal gestations have been reported recently, clinical diagnosis using magnetic resonance imaging (MRI), which introduced radiofrequency (RF) exposure, raised public concerns. The present study developed two whole-body pregnant models of 31 and 32 gestational weeks (GWs) with twin fetuses and explored RF exposure by 1.5 and 3.0 T MRI. Differences in the relative position of the fetus and changes in fetal weight can cause differences in fetal peak local specific absorption rate averaged over 10 g tissue (pSAR10g). Variation of pSAR10g due to different fetal positions can be ~35%. Numerically, twin and singleton fetal pSAR10g results were not significantly different, however twin results exceeded the limit in some cases (e.g. fetuses of 31 GW at 1.5 T), which indicated the necessity for further research employing anatomically correct twin-fetal models coming from various GWs and particular sequence to be applied.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiation protection dosimetry
Radiation protection dosimetry 环境科学-公共卫生、环境卫生与职业卫生
CiteScore
1.40
自引率
10.00%
发文量
223
审稿时长
6-12 weeks
期刊介绍: Radiation Protection Dosimetry covers all aspects of personal and environmental dosimetry and monitoring, for both ionising and non-ionising radiations. This includes biological aspects, physical concepts, biophysical dosimetry, external and internal personal dosimetry and monitoring, environmental and workplace monitoring, accident dosimetry, and dosimetry related to the protection of patients. Particular emphasis is placed on papers covering the fundamentals of dosimetry; units, radiation quantities and conversion factors. Papers covering archaeological dating are included only if the fundamental measurement method or technique, such as thermoluminescence, has direct application to personal dosimetry measurements. Papers covering the dosimetric aspects of radon or other naturally occurring radioactive materials and low level radiation are included. Animal experiments and ecological sample measurements are not included unless there is a significant relevant content reason.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信