用于评估更年期症状的巴西 10 项塞万提斯量表的验证。

Mona Lúcia Dall'Agno, Charles Francisco Ferreira, Fernanda Vargas Ferreira, Pedro do Valle Teichmann, Jéssica Zandoná, Faustino Ramón Pérez-López, Maria Celeste Osório Wender
{"title":"用于评估更年期症状的巴西 10 项塞万提斯量表的验证。","authors":"Mona Lúcia Dall'Agno, Charles Francisco Ferreira, Fernanda Vargas Ferreira, Pedro do Valle Teichmann, Jéssica Zandoná, Faustino Ramón Pérez-López, Maria Celeste Osório Wender","doi":"10.61622/rbgo/2024AO07","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To validate the 10-item Cervantes Scale (CS-10) among Brazilian women.</p><p><strong>Methods: </strong>This is a cross-sectional observational study involving women in the community aged 40-55 years in the Southern region of Brazil. They completed a general health, habits and socio-demographic questionnaire, the CS-10 and the Women's Health Questionnaire (WHQ). Women unable to understand the survey, not consenting to participate, or having incapacity imposing difficulties during the completion of the questionnaire were excluded. A Confirmatory Factor Analysis (CFA) was conducted with the AMOS 16.0 software. Chi-square of degrees of freedom (χ2/df), the Comparative Fit Index (CFI), the Tucker-Lewis Index (TLI) and the Root-Mean-Square Error of Approximation (RMSEA) were used as indices of goodness of fit. Cronbach's alpha coefficient was used for internal consistency.</p><p><strong>Results: </strong>A total of 422 women were included (premenopausal n=35, perimenopausal n=172, postmenopausal n=215). The CFA for the CS-10 showed a good fit (χ²/df=1.454, CFI=0.989; TLI=0.985; RMSEA=0.033; CI 90%=0.002-0.052; PCLOSE=0.921; Model p=0.049). Good reliability was established in CS-10 and WHQ (Cronbach's alpha=0.724). Postmenopausal women had higher total CS-10 scores (p≤0.0001), reflecting worse quality of life (QoL) related to menopause symptoms and confirming the greater symptomatology evaluated by high total scores for WHQ found in this population when compared to those in the premenopausal period (p=0.041).</p><p><strong>Conclusion: </strong>The CS-10 is a consistent tool for health-related QoL in Brazilian mid-aged women.</p>","PeriodicalId":74699,"journal":{"name":"Revista brasileira de ginecologia e obstetricia : revista da Federacao Brasileira das Sociedades de Ginecologia e Obstetricia","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11075430/pdf/","citationCount":"0","resultStr":"{\"title\":\"Validation of the Brazilian 10-item Cervantes Scale for the assessment of menopausal symptoms.\",\"authors\":\"Mona Lúcia Dall'Agno, Charles Francisco Ferreira, Fernanda Vargas Ferreira, Pedro do Valle Teichmann, Jéssica Zandoná, Faustino Ramón Pérez-López, Maria Celeste Osório Wender\",\"doi\":\"10.61622/rbgo/2024AO07\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To validate the 10-item Cervantes Scale (CS-10) among Brazilian women.</p><p><strong>Methods: </strong>This is a cross-sectional observational study involving women in the community aged 40-55 years in the Southern region of Brazil. They completed a general health, habits and socio-demographic questionnaire, the CS-10 and the Women's Health Questionnaire (WHQ). Women unable to understand the survey, not consenting to participate, or having incapacity imposing difficulties during the completion of the questionnaire were excluded. A Confirmatory Factor Analysis (CFA) was conducted with the AMOS 16.0 software. Chi-square of degrees of freedom (χ2/df), the Comparative Fit Index (CFI), the Tucker-Lewis Index (TLI) and the Root-Mean-Square Error of Approximation (RMSEA) were used as indices of goodness of fit. Cronbach's alpha coefficient was used for internal consistency.</p><p><strong>Results: </strong>A total of 422 women were included (premenopausal n=35, perimenopausal n=172, postmenopausal n=215). The CFA for the CS-10 showed a good fit (χ²/df=1.454, CFI=0.989; TLI=0.985; RMSEA=0.033; CI 90%=0.002-0.052; PCLOSE=0.921; Model p=0.049). Good reliability was established in CS-10 and WHQ (Cronbach's alpha=0.724). Postmenopausal women had higher total CS-10 scores (p≤0.0001), reflecting worse quality of life (QoL) related to menopause symptoms and confirming the greater symptomatology evaluated by high total scores for WHQ found in this population when compared to those in the premenopausal period (p=0.041).</p><p><strong>Conclusion: </strong>The CS-10 is a consistent tool for health-related QoL in Brazilian mid-aged women.</p>\",\"PeriodicalId\":74699,\"journal\":{\"name\":\"Revista brasileira de ginecologia e obstetricia : revista da Federacao Brasileira das Sociedades de Ginecologia e Obstetricia\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11075430/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista brasileira de ginecologia e obstetricia : revista da Federacao Brasileira das Sociedades de Ginecologia e Obstetricia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.61622/rbgo/2024AO07\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista brasileira de ginecologia e obstetricia : revista da Federacao Brasileira das Sociedades de Ginecologia e Obstetricia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.61622/rbgo/2024AO07","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的: 在巴西妇女中验证塞万提斯量表(CS-10)的 10 个项目:在巴西妇女中验证 10 项塞万提斯量表(CS-10):这是一项横断面观察研究,涉及巴西南部地区 40-55 岁的社区妇女。她们填写了一份一般健康、生活习惯和社会人口调查问卷、CS-10 和妇女健康问卷(WHQ)。无法理解调查内容、不同意参与调查或在填写问卷时遇到困难的妇女被排除在外。使用 AMOS 16.0 软件进行了确证因子分析(CFA)。自由度的卡方(χ2/df)、比较拟合指数(CFI)、塔克-刘易斯指数(TLI)和均方根近似误差(RMSEA)被用作拟合度指数。内部一致性采用 Cronbach's alpha 系数:共纳入 422 名妇女(绝经前 35 人,围绝经期 172 人,绝经后 215 人)。CS-10 的 CFA 显示拟合良好(χ²/df=1.454,CFI=0.989,TLI=0.985,RMSEA=0.033,CI 90%=0.002-0.052,PCLOSE=0.921,模型 p=0.049)。CS-10 和 WHQ 具有良好的可靠性(Cronbach's alpha=0.724)。绝经后妇女的 CS-10 总分更高(p≤0.0001),这反映出与绝经症状相关的生活质量(QoL)更差,同时也证实了与绝经前妇女相比,绝经后妇女的 WHQ 总分更高(p=0.041),这说明绝经后妇女的症状更严重:结论:CS-10 是巴西中年女性健康相关 QoL 的一致工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Validation of the Brazilian 10-item Cervantes Scale for the assessment of menopausal symptoms.

Objective: To validate the 10-item Cervantes Scale (CS-10) among Brazilian women.

Methods: This is a cross-sectional observational study involving women in the community aged 40-55 years in the Southern region of Brazil. They completed a general health, habits and socio-demographic questionnaire, the CS-10 and the Women's Health Questionnaire (WHQ). Women unable to understand the survey, not consenting to participate, or having incapacity imposing difficulties during the completion of the questionnaire were excluded. A Confirmatory Factor Analysis (CFA) was conducted with the AMOS 16.0 software. Chi-square of degrees of freedom (χ2/df), the Comparative Fit Index (CFI), the Tucker-Lewis Index (TLI) and the Root-Mean-Square Error of Approximation (RMSEA) were used as indices of goodness of fit. Cronbach's alpha coefficient was used for internal consistency.

Results: A total of 422 women were included (premenopausal n=35, perimenopausal n=172, postmenopausal n=215). The CFA for the CS-10 showed a good fit (χ²/df=1.454, CFI=0.989; TLI=0.985; RMSEA=0.033; CI 90%=0.002-0.052; PCLOSE=0.921; Model p=0.049). Good reliability was established in CS-10 and WHQ (Cronbach's alpha=0.724). Postmenopausal women had higher total CS-10 scores (p≤0.0001), reflecting worse quality of life (QoL) related to menopause symptoms and confirming the greater symptomatology evaluated by high total scores for WHQ found in this population when compared to those in the premenopausal period (p=0.041).

Conclusion: The CS-10 is a consistent tool for health-related QoL in Brazilian mid-aged women.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信