在关节镜下修复 Ideberg IA 型盂骨骨折的双滑轮 V 型固定技术。

IF 1.6 4区 医学
Baichuan Li, Ke Rong, Haiquan Deng, Zhongfei Tang, Jian Tang, Jianchao Sun
{"title":"在关节镜下修复 Ideberg IA 型盂骨骨折的双滑轮 V 型固定技术。","authors":"Baichuan Li, Ke Rong, Haiquan Deng, Zhongfei Tang, Jian Tang, Jianchao Sun","doi":"10.1177/10225536241254913","DOIUrl":null,"url":null,"abstract":"<p><p>Different techniques have been described for glenoid fractures, there is still a need for safe and effective agents to promote outcomes. From January 2016 to April 2021, the clinical data of 17 patients with pulley type IA fractures treated by the V-shaped fixation technique under shoulder arthroscopy were retrospectively analyzed. Preoperative X-ray, CT, and MRI examinations were completed. The functional score of the shoulder joint, such as the visual analog scale (VAS), Constant score, and Modified Rowe score, was used to evaluate the preoperative and final follow-up clinical outcomes. The active shoulder range of motion (ROM) was also collected preoperatively and at the final postoperative follow-up. Accordingly, intraoperative and postoperative complications were also observed. The mean follow-up was 49.52 months (16-79 months). The patients' follow-up exams showed that shoulder joint flexion, abduction, external rotation, internal rotation, and pain were not significantly different from those of the contralateral side (<i>p</i> > .05). The mean Constant score was 83.52 (58-98), and the average Modified Rowe score was 94.29 (70-100). X-ray and CT films of all cases showed good healing without articular depression or steps. Three patients had traumatic arthritis, with VAS <3 pain. No postoperative complications, such as infections, nerve or vessel damage, or suture anchor problems occurred during the follow-up period. Using the Double-pull, V-shaped fixation technique can stabilize the reduction of glenoid fractures while reducing the possibility of bone destruction. It is a good solution and provides an opportunity to treat rotator cuff tears associated with the procedure.</p>","PeriodicalId":16608,"journal":{"name":"Journal of Orthopaedic Surgery","volume":"32 2","pages":"10225536241254913"},"PeriodicalIF":1.6000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Double-pulley, V-shaped fixation technique for arthroscopic repair of ideberg type IA glenoid fracture.\",\"authors\":\"Baichuan Li, Ke Rong, Haiquan Deng, Zhongfei Tang, Jian Tang, Jianchao Sun\",\"doi\":\"10.1177/10225536241254913\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Different techniques have been described for glenoid fractures, there is still a need for safe and effective agents to promote outcomes. From January 2016 to April 2021, the clinical data of 17 patients with pulley type IA fractures treated by the V-shaped fixation technique under shoulder arthroscopy were retrospectively analyzed. Preoperative X-ray, CT, and MRI examinations were completed. The functional score of the shoulder joint, such as the visual analog scale (VAS), Constant score, and Modified Rowe score, was used to evaluate the preoperative and final follow-up clinical outcomes. The active shoulder range of motion (ROM) was also collected preoperatively and at the final postoperative follow-up. Accordingly, intraoperative and postoperative complications were also observed. The mean follow-up was 49.52 months (16-79 months). The patients' follow-up exams showed that shoulder joint flexion, abduction, external rotation, internal rotation, and pain were not significantly different from those of the contralateral side (<i>p</i> > .05). The mean Constant score was 83.52 (58-98), and the average Modified Rowe score was 94.29 (70-100). X-ray and CT films of all cases showed good healing without articular depression or steps. Three patients had traumatic arthritis, with VAS <3 pain. No postoperative complications, such as infections, nerve or vessel damage, or suture anchor problems occurred during the follow-up period. Using the Double-pull, V-shaped fixation technique can stabilize the reduction of glenoid fractures while reducing the possibility of bone destruction. It is a good solution and provides an opportunity to treat rotator cuff tears associated with the procedure.</p>\",\"PeriodicalId\":16608,\"journal\":{\"name\":\"Journal of Orthopaedic Surgery\",\"volume\":\"32 2\",\"pages\":\"10225536241254913\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orthopaedic Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/10225536241254913\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/10225536241254913","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对于盂兰盆骨折的治疗,目前已有不同的技术,但仍需要安全有效的药物来提高疗效。自2016年1月至2021年4月,对17例在肩关节镜下采用V形固定技术治疗的滑轮IA型骨折患者的临床资料进行了回顾性分析。术前完成了 X 光、CT 和 MRI 检查。肩关节功能评分,如视觉模拟量表(VAS)、Constant评分和改良Rowe评分,用于评估术前和最终随访的临床结果。此外,还收集了术前和术后最终随访时的肩关节活动范围(ROM)。此外,还对术中和术后并发症进行了观察。平均随访时间为 49.52 个月(16-79 个月)。患者的随访检查结果显示,肩关节屈曲、外展、外旋、内旋和疼痛与对侧没有明显差异(P > .05)。平均 Constant 评分为 83.52(58-98)分,平均 Modified Rowe 评分为 94.29(70-100)分。所有病例的 X 光片和 CT 片均显示愈合良好,无关节凹陷或阶梯。三名患者患有创伤性关节炎,其 VAS
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Double-pulley, V-shaped fixation technique for arthroscopic repair of ideberg type IA glenoid fracture.

Different techniques have been described for glenoid fractures, there is still a need for safe and effective agents to promote outcomes. From January 2016 to April 2021, the clinical data of 17 patients with pulley type IA fractures treated by the V-shaped fixation technique under shoulder arthroscopy were retrospectively analyzed. Preoperative X-ray, CT, and MRI examinations were completed. The functional score of the shoulder joint, such as the visual analog scale (VAS), Constant score, and Modified Rowe score, was used to evaluate the preoperative and final follow-up clinical outcomes. The active shoulder range of motion (ROM) was also collected preoperatively and at the final postoperative follow-up. Accordingly, intraoperative and postoperative complications were also observed. The mean follow-up was 49.52 months (16-79 months). The patients' follow-up exams showed that shoulder joint flexion, abduction, external rotation, internal rotation, and pain were not significantly different from those of the contralateral side (p > .05). The mean Constant score was 83.52 (58-98), and the average Modified Rowe score was 94.29 (70-100). X-ray and CT films of all cases showed good healing without articular depression or steps. Three patients had traumatic arthritis, with VAS <3 pain. No postoperative complications, such as infections, nerve or vessel damage, or suture anchor problems occurred during the follow-up period. Using the Double-pull, V-shaped fixation technique can stabilize the reduction of glenoid fractures while reducing the possibility of bone destruction. It is a good solution and provides an opportunity to treat rotator cuff tears associated with the procedure.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
91
期刊介绍: Journal of Orthopaedic Surgery is an open access peer-reviewed journal publishing original reviews and research articles on all aspects of orthopaedic surgery. It is the official journal of the Asia Pacific Orthopaedic Association. The journal welcomes and will publish materials of a diverse nature, from basic science research to clinical trials and surgical techniques. The journal encourages contributions from all parts of the world, but special emphasis is given to research of particular relevance to the Asia Pacific region.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信