Pascal Frederiks, Gianluca Castaldi, Keir McCutcheon, Johan Bennett
{"title":"用于治疗(复杂)冠状动脉疾病的铂铬依维莫司洗脱支架;从 SYNERGY™ 到 MEGATRON™。","authors":"Pascal Frederiks, Gianluca Castaldi, Keir McCutcheon, Johan Bennett","doi":"10.1080/17434440.2024.2353722","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The introduction of drug-eluting coronary stents (DES) into clinical practice in 2002 represented a major milestone in the treatment of obstructive coronary artery disease. Over the years, significant advances in polymer coating and in antiproliferative agent technology have further improved the safety and clinical performance of newer-generation DES.</p><p><strong>Areas covered: </strong>Development of platinum chromium (PtCr) alloys with high radial strength and high radiopacity have enabled the design of new, thin-strut, flexible, and highly trackable stent platforms, while simultaneously improving stent visibility. These advances have facilitated complex percutaneous treatment of a diverse population of patients in clinical practice. This review will provide an overview of the evolution in PtCr everolimus-eluting stents from PROMUS Element™ to SYNERGY™ to the recently introduced SYNERGY MEGATRON™. The clinical data will be summarized and put into perspective, especially focusing on the role of the SYNERGY™ and MEGATRON™ platforms in the treatment of complex coronary artery disease and high-risk patients.</p><p><strong>Expert opinion: </strong>The SYNERGY™ stent demonstrates favorable clinical efficacy and safety outcome data, and whilst the clinical data on MEGATRON™ are sparse, early experience is promising. The specific overexpansion capabilities, visibility, and radial strength of the MEGATRON™ are attractive features for complex coronary interventions.</p>","PeriodicalId":94006,"journal":{"name":"Expert review of medical devices","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Platinum chromium everolimus-eluting stents for the treatment of (complex) coronary artery disease; from SYNERGY™ to the MEGATRON™.\",\"authors\":\"Pascal Frederiks, Gianluca Castaldi, Keir McCutcheon, Johan Bennett\",\"doi\":\"10.1080/17434440.2024.2353722\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The introduction of drug-eluting coronary stents (DES) into clinical practice in 2002 represented a major milestone in the treatment of obstructive coronary artery disease. Over the years, significant advances in polymer coating and in antiproliferative agent technology have further improved the safety and clinical performance of newer-generation DES.</p><p><strong>Areas covered: </strong>Development of platinum chromium (PtCr) alloys with high radial strength and high radiopacity have enabled the design of new, thin-strut, flexible, and highly trackable stent platforms, while simultaneously improving stent visibility. These advances have facilitated complex percutaneous treatment of a diverse population of patients in clinical practice. This review will provide an overview of the evolution in PtCr everolimus-eluting stents from PROMUS Element™ to SYNERGY™ to the recently introduced SYNERGY MEGATRON™. The clinical data will be summarized and put into perspective, especially focusing on the role of the SYNERGY™ and MEGATRON™ platforms in the treatment of complex coronary artery disease and high-risk patients.</p><p><strong>Expert opinion: </strong>The SYNERGY™ stent demonstrates favorable clinical efficacy and safety outcome data, and whilst the clinical data on MEGATRON™ are sparse, early experience is promising. The specific overexpansion capabilities, visibility, and radial strength of the MEGATRON™ are attractive features for complex coronary interventions.</p>\",\"PeriodicalId\":94006,\"journal\":{\"name\":\"Expert review of medical devices\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Expert review of medical devices\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/17434440.2024.2353722\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert review of medical devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/17434440.2024.2353722","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/13 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
Platinum chromium everolimus-eluting stents for the treatment of (complex) coronary artery disease; from SYNERGY™ to the MEGATRON™.
Introduction: The introduction of drug-eluting coronary stents (DES) into clinical practice in 2002 represented a major milestone in the treatment of obstructive coronary artery disease. Over the years, significant advances in polymer coating and in antiproliferative agent technology have further improved the safety and clinical performance of newer-generation DES.
Areas covered: Development of platinum chromium (PtCr) alloys with high radial strength and high radiopacity have enabled the design of new, thin-strut, flexible, and highly trackable stent platforms, while simultaneously improving stent visibility. These advances have facilitated complex percutaneous treatment of a diverse population of patients in clinical practice. This review will provide an overview of the evolution in PtCr everolimus-eluting stents from PROMUS Element™ to SYNERGY™ to the recently introduced SYNERGY MEGATRON™. The clinical data will be summarized and put into perspective, especially focusing on the role of the SYNERGY™ and MEGATRON™ platforms in the treatment of complex coronary artery disease and high-risk patients.
Expert opinion: The SYNERGY™ stent demonstrates favorable clinical efficacy and safety outcome data, and whilst the clinical data on MEGATRON™ are sparse, early experience is promising. The specific overexpansion capabilities, visibility, and radial strength of the MEGATRON™ are attractive features for complex coronary interventions.