{"title":"[将 LDBIO Diagnostics® TOXOPLASMA ICT IGG-IGM 与 Siemens Atellica® IM 联合用于弓形虫血清学筛查]。","authors":"Mickael Fortun, Julien L'hirondel","doi":"10.1684/abc.2024.1875","DOIUrl":null,"url":null,"abstract":"<p><p>According to French recommendations for serological screening of toxoplasmosis, some profiles must be confirmed by additional methods, extending the time taken to produce results. Thus, the Laborizon Bretagne technical platform in Nantes studied the place of the LDBIO Diagnostics® TOXOPLASMA ICT IGG-IGM (ICT) test in addition to Siemens Atellica® serology. IgG-/IgM+ and equivocal or weak positive IgG/IgM- (IgGEq/IgM-) profiles on Atellica® will be confirmed by ICT, Alinity® Abbott and Platelia® Biorad. Among the 66 IgGEq/IgM- profiles, the concordance is perfect between ICT and complementary techniques: 21 weak positives were confirmed positive, 8 equivocal were considered negative and 37 were confirmed positive. Concerning the 76 IgG-/IgM+ profiles, 68 are negative and 7 are positive by complementary techniques and ICT. One discordance was observed. The Atellica®/ICT combination allows excellent discrimination of IgG-/IgM+ and IgGEq/IgM serological profiles with consistent diagnostic orientation in 99.3% of cases. Only 1 sample was found to be discordant but required monitoring at 15 days. The observed performances are compatible with routine use. This test simplifies the analytical process, improves the time to obtain results, while guaranteeing an excellent level of quality.</p>","PeriodicalId":93870,"journal":{"name":"Annales de biologie clinique","volume":"82 1","pages":"81-92"},"PeriodicalIF":0.0000,"publicationDate":"2024-04-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Use of LDBIO Diagnostics<sup>®</sup> TOXOPLASMA ICT IGG-IGM in association with Siemens Atellica<sup>®</sup> IM in toxoplasmosis serological screening].\",\"authors\":\"Mickael Fortun, Julien L'hirondel\",\"doi\":\"10.1684/abc.2024.1875\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>According to French recommendations for serological screening of toxoplasmosis, some profiles must be confirmed by additional methods, extending the time taken to produce results. Thus, the Laborizon Bretagne technical platform in Nantes studied the place of the LDBIO Diagnostics® TOXOPLASMA ICT IGG-IGM (ICT) test in addition to Siemens Atellica® serology. IgG-/IgM+ and equivocal or weak positive IgG/IgM- (IgGEq/IgM-) profiles on Atellica® will be confirmed by ICT, Alinity® Abbott and Platelia® Biorad. Among the 66 IgGEq/IgM- profiles, the concordance is perfect between ICT and complementary techniques: 21 weak positives were confirmed positive, 8 equivocal were considered negative and 37 were confirmed positive. Concerning the 76 IgG-/IgM+ profiles, 68 are negative and 7 are positive by complementary techniques and ICT. One discordance was observed. The Atellica®/ICT combination allows excellent discrimination of IgG-/IgM+ and IgGEq/IgM serological profiles with consistent diagnostic orientation in 99.3% of cases. Only 1 sample was found to be discordant but required monitoring at 15 days. The observed performances are compatible with routine use. This test simplifies the analytical process, improves the time to obtain results, while guaranteeing an excellent level of quality.</p>\",\"PeriodicalId\":93870,\"journal\":{\"name\":\"Annales de biologie clinique\",\"volume\":\"82 1\",\"pages\":\"81-92\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annales de biologie clinique\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1684/abc.2024.1875\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annales de biologie clinique","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1684/abc.2024.1875","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

根据法国对弓形虫血清学筛查的建议,某些特征必须通过其他方法进行确认,从而延长了得出结果所需的时间。因此,位于南特的 Laborizon Bretagne 技术平台研究了除西门子 Atellica® 血清学检测外,LDBIO Diagnostics® TOXOPLASMA ICT IG-IGM (ICT) 检测的位置。Atellica®上的IgG-/IgM+和IgG/IgM-(IgGEq/IgM-)等位或弱阳性图谱将通过ICT、Alinity® Abbott和Platelia® Biorad来确认。在 66 份 IgGEq/IgM- 图谱中,ICT 与互补技术之间的一致性非常好:21 份弱阳性图谱被确认为阳性,8 份模棱两可的图谱被视为阴性,37 份被确认为阳性。在 76 份 IgG-/IgM+ 图谱中,68 份为阴性,7 份为阳性。观察到一个不一致的结果。Atellica®/ICT 组合能很好地区分 IgG-/IgM+ 和 IgGEq/IgM 血清学特征,99.3% 的病例诊断方向一致。只有一个样本不一致,但需要在 15 天后进行监测。观察到的性能符合常规使用要求。该检验简化了分析过程,缩短了获得结果的时间,同时保证了优良的质量水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Use of LDBIO Diagnostics® TOXOPLASMA ICT IGG-IGM in association with Siemens Atellica® IM in toxoplasmosis serological screening].

According to French recommendations for serological screening of toxoplasmosis, some profiles must be confirmed by additional methods, extending the time taken to produce results. Thus, the Laborizon Bretagne technical platform in Nantes studied the place of the LDBIO Diagnostics® TOXOPLASMA ICT IGG-IGM (ICT) test in addition to Siemens Atellica® serology. IgG-/IgM+ and equivocal or weak positive IgG/IgM- (IgGEq/IgM-) profiles on Atellica® will be confirmed by ICT, Alinity® Abbott and Platelia® Biorad. Among the 66 IgGEq/IgM- profiles, the concordance is perfect between ICT and complementary techniques: 21 weak positives were confirmed positive, 8 equivocal were considered negative and 37 were confirmed positive. Concerning the 76 IgG-/IgM+ profiles, 68 are negative and 7 are positive by complementary techniques and ICT. One discordance was observed. The Atellica®/ICT combination allows excellent discrimination of IgG-/IgM+ and IgGEq/IgM serological profiles with consistent diagnostic orientation in 99.3% of cases. Only 1 sample was found to be discordant but required monitoring at 15 days. The observed performances are compatible with routine use. This test simplifies the analytical process, improves the time to obtain results, while guaranteeing an excellent level of quality.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信