{"title":"[含有大豆或玉米的加工食品的 DNA 提取方法比较]。","authors":"Tomohiro Egi, Reona Takabatake, Masahiro Kishine, Keisuke Soga, Satoko Yoshiba, Norihito Shibata, Kazunari Kondo, Yasuharu Takashima","doi":"10.3358/shokueishi.65.25","DOIUrl":null,"url":null,"abstract":"<p><p>Processed foods containing soybean or maize are subject to labeling regulations pertinent to genetically modified (GM) foods in Japan. To confirm the reliability of the labeling procedure of GM foods, the Japanese standard analytical methods (standard methods) using real-time PCR technique have been established. Although certain DNA extraction protocols are stipulated as standard in these methods, the use of other protocols confirmed to be equivalent to the existing ones was permitted. In this study, the equivalence testing of the techniques employed for DNA extraction from processed foods containing soybean or corn was conducted. In this study, the equivalence testing of the techniques employed for DNA extraction from processed foods containing soybean or maize was conducted. The silica membrane-based DNA extraction kits, GM quicker 4 and DNeasy Plant Maxi Kit (Maxi Kit), as an existing method were compared. GM quicker 4 was considered to be equivalent to or better than Maxi Kit.</p>","PeriodicalId":54373,"journal":{"name":"Food Hygiene and Safety Science","volume":"65 2","pages":"25-30"},"PeriodicalIF":0.2000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Comparison of DNA Extraction Methods for Processed Foods Containing Soybean or Maize].\",\"authors\":\"Tomohiro Egi, Reona Takabatake, Masahiro Kishine, Keisuke Soga, Satoko Yoshiba, Norihito Shibata, Kazunari Kondo, Yasuharu Takashima\",\"doi\":\"10.3358/shokueishi.65.25\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Processed foods containing soybean or maize are subject to labeling regulations pertinent to genetically modified (GM) foods in Japan. To confirm the reliability of the labeling procedure of GM foods, the Japanese standard analytical methods (standard methods) using real-time PCR technique have been established. Although certain DNA extraction protocols are stipulated as standard in these methods, the use of other protocols confirmed to be equivalent to the existing ones was permitted. In this study, the equivalence testing of the techniques employed for DNA extraction from processed foods containing soybean or corn was conducted. In this study, the equivalence testing of the techniques employed for DNA extraction from processed foods containing soybean or maize was conducted. The silica membrane-based DNA extraction kits, GM quicker 4 and DNeasy Plant Maxi Kit (Maxi Kit), as an existing method were compared. GM quicker 4 was considered to be equivalent to or better than Maxi Kit.</p>\",\"PeriodicalId\":54373,\"journal\":{\"name\":\"Food Hygiene and Safety Science\",\"volume\":\"65 2\",\"pages\":\"25-30\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Food Hygiene and Safety Science\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.3358/shokueishi.65.25\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"FOOD SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Food Hygiene and Safety Science","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.3358/shokueishi.65.25","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"FOOD SCIENCE & TECHNOLOGY","Score":null,"Total":0}
[Comparison of DNA Extraction Methods for Processed Foods Containing Soybean or Maize].
Processed foods containing soybean or maize are subject to labeling regulations pertinent to genetically modified (GM) foods in Japan. To confirm the reliability of the labeling procedure of GM foods, the Japanese standard analytical methods (standard methods) using real-time PCR technique have been established. Although certain DNA extraction protocols are stipulated as standard in these methods, the use of other protocols confirmed to be equivalent to the existing ones was permitted. In this study, the equivalence testing of the techniques employed for DNA extraction from processed foods containing soybean or corn was conducted. In this study, the equivalence testing of the techniques employed for DNA extraction from processed foods containing soybean or maize was conducted. The silica membrane-based DNA extraction kits, GM quicker 4 and DNeasy Plant Maxi Kit (Maxi Kit), as an existing method were compared. GM quicker 4 was considered to be equivalent to or better than Maxi Kit.