LASIK 并发症后的视觉康复:皮瓣截肢、拓扑引导手术和超声乳化术。

IF 1.1 4区 医学 Q3 OPHTHALMOLOGY
Arquivos brasileiros de oftalmologia Pub Date : 2024-04-19 eCollection Date: 2024-01-01 DOI:10.5935/0004-2749.2023-0221
Frederico França Marques, Daniel Filipe Oliveira Rabelo, Daniela Meira Villano Marques, Glauco Sérgio Avelino de Aquino, Daniel Diniz da Gama, Bernardo Kaplan Moscovici
{"title":"LASIK 并发症后的视觉康复:皮瓣截肢、拓扑引导手术和超声乳化术。","authors":"Frederico França Marques, Daniel Filipe Oliveira Rabelo, Daniela Meira Villano Marques, Glauco Sérgio Avelino de Aquino, Daniel Diniz da Gama, Bernardo Kaplan Moscovici","doi":"10.5935/0004-2749.2023-0221","DOIUrl":null,"url":null,"abstract":"<p><p>We present a case of a patient complaining of monocular diplopia due to a decentered ablation after LASIK. The patient underwent a wavefront-guided retreatment, which resulted in an epithelial ingrowth complication. Additionally, the patient developed cataract, with cataract surgery requiring reliable biometric measurements. Therefore, we opted for corneal treatment and corneal surface regularization. Although we attempted to lift the flap and wash the interface initially, the procedure proved unsuccessful, thereby necessitating immediate flap amputation. Once the corneal surface was regularized in the seventh postoperative month, transepithelial photorefractive keratectomy was successfully performed to homogenize the ocular surface, thereby significantly improving the patient's corrected visual acuity and resolving monocular diplopia. The surface and corneal curvature stabilized by the fifth month after the procedure. Phacoemulsification was then performed along with the implantation of a toric monofocal lens, which was selected using an appropriate formula, resulting in an excellent uncorrected visual acuity.</p>","PeriodicalId":8397,"journal":{"name":"Arquivos brasileiros de oftalmologia","volume":"87 4","pages":"e2023"},"PeriodicalIF":1.1000,"publicationDate":"2024-04-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Visual rehabilitation after LASIK complication: flap amputation, topo-guided surgery, and phacoemulsification.\",\"authors\":\"Frederico França Marques, Daniel Filipe Oliveira Rabelo, Daniela Meira Villano Marques, Glauco Sérgio Avelino de Aquino, Daniel Diniz da Gama, Bernardo Kaplan Moscovici\",\"doi\":\"10.5935/0004-2749.2023-0221\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We present a case of a patient complaining of monocular diplopia due to a decentered ablation after LASIK. The patient underwent a wavefront-guided retreatment, which resulted in an epithelial ingrowth complication. Additionally, the patient developed cataract, with cataract surgery requiring reliable biometric measurements. Therefore, we opted for corneal treatment and corneal surface regularization. Although we attempted to lift the flap and wash the interface initially, the procedure proved unsuccessful, thereby necessitating immediate flap amputation. Once the corneal surface was regularized in the seventh postoperative month, transepithelial photorefractive keratectomy was successfully performed to homogenize the ocular surface, thereby significantly improving the patient's corrected visual acuity and resolving monocular diplopia. The surface and corneal curvature stabilized by the fifth month after the procedure. Phacoemulsification was then performed along with the implantation of a toric monofocal lens, which was selected using an appropriate formula, resulting in an excellent uncorrected visual acuity.</p>\",\"PeriodicalId\":8397,\"journal\":{\"name\":\"Arquivos brasileiros de oftalmologia\",\"volume\":\"87 4\",\"pages\":\"e2023\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-04-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Arquivos brasileiros de oftalmologia\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5935/0004-2749.2023-0221\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arquivos brasileiros de oftalmologia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5935/0004-2749.2023-0221","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

我们报告了一例患者的病例,该患者主诉因 LASIK 术后分散消融而导致单眼复视。患者接受了波前引导下的再治疗,结果出现了上皮增生并发症。此外,患者还患上了白内障,而白内障手术需要可靠的生物测量。因此,我们选择了角膜治疗和角膜表面规整术。虽然一开始我们尝试掀开角膜瓣并清洗界面,但手术并不成功,因此必须立即截除角膜瓣。术后第七个月,角膜表面规整后,我们成功实施了经上皮光屈光性角膜切除术,使眼表均匀化,从而显著提高了患者的矫正视力,并解决了单眼复视问题。术后第五个月,眼表和角膜曲率趋于稳定。随后,患者接受了乳化手术,并植入了散光单焦点镜片。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Visual rehabilitation after LASIK complication: flap amputation, topo-guided surgery, and phacoemulsification.

We present a case of a patient complaining of monocular diplopia due to a decentered ablation after LASIK. The patient underwent a wavefront-guided retreatment, which resulted in an epithelial ingrowth complication. Additionally, the patient developed cataract, with cataract surgery requiring reliable biometric measurements. Therefore, we opted for corneal treatment and corneal surface regularization. Although we attempted to lift the flap and wash the interface initially, the procedure proved unsuccessful, thereby necessitating immediate flap amputation. Once the corneal surface was regularized in the seventh postoperative month, transepithelial photorefractive keratectomy was successfully performed to homogenize the ocular surface, thereby significantly improving the patient's corrected visual acuity and resolving monocular diplopia. The surface and corneal curvature stabilized by the fifth month after the procedure. Phacoemulsification was then performed along with the implantation of a toric monofocal lens, which was selected using an appropriate formula, resulting in an excellent uncorrected visual acuity.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.60
自引率
0.00%
发文量
200
审稿时长
6-12 weeks
期刊介绍: The ABO-ARQUIVOS BRASILEIROS DE OFTALMOLOGIA (ABO, ISSN 0004-2749 - print and ISSN 1678-2925 - (ABO, ISSN 0004-2749 - print and ISSN 1678-2925 - electronic version), the official bimonthly publication of the Brazilian Council of Ophthalmology (CBO), aims to disseminate scientific studies in Ophthalmology, Visual Science and Health public, by promoting research, improvement and updating of professionals related to the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信