{"title":"在二维剪切波弹性成像中验证晚期肝纤维化的 Baveno 弹性成像标准:基于病理学的前瞻性研究","authors":"Chia-Chang Chen, Yao-Kuang Huang, Ren-Ching Wang, Jing-Tong Fu, Shou-Wu Lee, Hsin-Ju Tsai, Sheng-Shun Yang, Teng-Yu Lee","doi":"10.1159/000539167","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The Baveno criteria for assessing advanced liver fibrosis were mainly determined by transient elastography (TE), and its pathology-based validation studies in two-dimensional shear wave elastography (2D-SWE) remain limited. We aimed to validate the Baveno criteria through use of 2D-SWE.</p><p><strong>Method: </strong>Consecutive patients who underwent liver biopsies for various benign liver diseases were prospectively recruited. Liver stiffness measurement (LSM) was simultaneously evaluated by TE and 2D-SWE. The optimal cutoff value to predict advanced liver fibrosis was determined by the Youden Index, and the diagnostic performance was estimated using area under the receiver operating characteristic (AUROC) analysis.</p><p><strong>Results: </strong>A total of 101 patients were enrolled having a median age of 55.0 (IQR: 46.0-63.5) years, with 53 (52.48%) of them being male. Using &lt;9 and &gt;14 kPa as the optimal dual cutoffs, the AUROC values in TE and 2D-SWE were 0.92 (95% CI: 0.83-0.97) and 0.93 (95% CI: 0.84-0.98), respectively (p = 0.61). The sensitivity and specificity of LSM by TE/2D-SWE achieved rates of 94.44%/94.44% and 86.00%/88.00%, respectively. However, using the Baveno criteria, the AUROC values in TE and 2D-SWE could remain achieving 0.91 (95% CI: 0.82-0.97) and 0.93 (95% CI: 0.84-0.98), respectively (p = 0.36). The sensitivity and specificity in TE/2D-SWE were 88.24%/88.24% and 86.79%/90.57%, respectively.</p><p><strong>Conclusion: </strong>This study establishes the compatibility of the Baveno dual cutoff criteria with 2D-SWE, positioning it as an easily used criteria in clinical practice and research.</p>","PeriodicalId":11294,"journal":{"name":"Digestive Diseases","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validating the Baveno Elastography Criteria of Advanced Liver Fibrosis in Two-Dimensional Shear Wave Elastography: A Prospective Pathology-Based Study.\",\"authors\":\"Chia-Chang Chen, Yao-Kuang Huang, Ren-Ching Wang, Jing-Tong Fu, Shou-Wu Lee, Hsin-Ju Tsai, Sheng-Shun Yang, Teng-Yu Lee\",\"doi\":\"10.1159/000539167\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The Baveno criteria for assessing advanced liver fibrosis were mainly determined by transient elastography (TE), and its pathology-based validation studies in two-dimensional shear wave elastography (2D-SWE) remain limited. We aimed to validate the Baveno criteria through use of 2D-SWE.</p><p><strong>Method: </strong>Consecutive patients who underwent liver biopsies for various benign liver diseases were prospectively recruited. Liver stiffness measurement (LSM) was simultaneously evaluated by TE and 2D-SWE. The optimal cutoff value to predict advanced liver fibrosis was determined by the Youden Index, and the diagnostic performance was estimated using area under the receiver operating characteristic (AUROC) analysis.</p><p><strong>Results: </strong>A total of 101 patients were enrolled having a median age of 55.0 (IQR: 46.0-63.5) years, with 53 (52.48%) of them being male. Using &lt;9 and &gt;14 kPa as the optimal dual cutoffs, the AUROC values in TE and 2D-SWE were 0.92 (95% CI: 0.83-0.97) and 0.93 (95% CI: 0.84-0.98), respectively (p = 0.61). The sensitivity and specificity of LSM by TE/2D-SWE achieved rates of 94.44%/94.44% and 86.00%/88.00%, respectively. However, using the Baveno criteria, the AUROC values in TE and 2D-SWE could remain achieving 0.91 (95% CI: 0.82-0.97) and 0.93 (95% CI: 0.84-0.98), respectively (p = 0.36). The sensitivity and specificity in TE/2D-SWE were 88.24%/88.24% and 86.79%/90.57%, respectively.</p><p><strong>Conclusion: </strong>This study establishes the compatibility of the Baveno dual cutoff criteria with 2D-SWE, positioning it as an easily used criteria in clinical practice and research.</p>\",\"PeriodicalId\":11294,\"journal\":{\"name\":\"Digestive Diseases\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-05-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Digestive Diseases\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1159/000539167\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"GASTROENTEROLOGY & HEPATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digestive Diseases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000539167","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

简介:评估晚期肝纤维化的 Baveno 标准主要是通过瞬态弹性成像(TE)确定的,其基于病理学的二维剪切波弹性成像(2D-SWE)验证研究仍然有限。我们的目的是通过二维剪切波弹性成像来验证巴韦诺标准:方法:前瞻性招募因各种良性肝病接受肝活检的连续患者。通过 TE 和 2D-SWE 同时评估肝脏僵硬度测量(LSM)。通过尤登指数(Youden Index)确定预测晚期肝纤维化的最佳临界值,并使用接收者操作特征下面积(AUROC)分析估算诊断性能:共纳入 101 名患者,中位年龄为 55.0(IQR:46.0-63.5)岁,其中 53 名(52.48%)为男性。以<9和>14 kPa作为最佳双临界值,TE和2D-SWE的AUROC值分别为0.92(95% CI:0.83-0.97)和0.93(95% CI:0.84-0.98)(P= 0.61)。通过 TE/2D-SWE 进行 LSM 的灵敏度和特异性分别达到 94.44%/94.44% 和 86.00%/88.00% 。然而,使用 Baveno 标准,TE 和 2D-SWE 的 AUROC 值仍可分别达到 0.91(95% CI:0.82-0.97)和 0.93(95% CI:0.84-0.98)(P= 0.36)。TE/2D-SWE的敏感性和特异性分别为88.24%/88.24%和86.79%/90.57%:本研究确定了 Baveno 双截断标准与 2D-SWE 的兼容性,使其成为临床实践和研究中易于使用的标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Validating the Baveno Elastography Criteria of Advanced Liver Fibrosis in Two-Dimensional Shear Wave Elastography: A Prospective Pathology-Based Study.

Introduction: The Baveno criteria for assessing advanced liver fibrosis were mainly determined by transient elastography (TE), and its pathology-based validation studies in two-dimensional shear wave elastography (2D-SWE) remain limited. We aimed to validate the Baveno criteria through use of 2D-SWE.

Method: Consecutive patients who underwent liver biopsies for various benign liver diseases were prospectively recruited. Liver stiffness measurement (LSM) was simultaneously evaluated by TE and 2D-SWE. The optimal cutoff value to predict advanced liver fibrosis was determined by the Youden Index, and the diagnostic performance was estimated using area under the receiver operating characteristic (AUROC) analysis.

Results: A total of 101 patients were enrolled having a median age of 55.0 (IQR: 46.0-63.5) years, with 53 (52.48%) of them being male. Using <9 and >14 kPa as the optimal dual cutoffs, the AUROC values in TE and 2D-SWE were 0.92 (95% CI: 0.83-0.97) and 0.93 (95% CI: 0.84-0.98), respectively (p = 0.61). The sensitivity and specificity of LSM by TE/2D-SWE achieved rates of 94.44%/94.44% and 86.00%/88.00%, respectively. However, using the Baveno criteria, the AUROC values in TE and 2D-SWE could remain achieving 0.91 (95% CI: 0.82-0.97) and 0.93 (95% CI: 0.84-0.98), respectively (p = 0.36). The sensitivity and specificity in TE/2D-SWE were 88.24%/88.24% and 86.79%/90.57%, respectively.

Conclusion: This study establishes the compatibility of the Baveno dual cutoff criteria with 2D-SWE, positioning it as an easily used criteria in clinical practice and research.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Digestive Diseases
Digestive Diseases 医学-胃肠肝病学
CiteScore
4.80
自引率
0.00%
发文量
58
审稿时长
2 months
期刊介绍: Each issue of this journal is dedicated to a special topic of current interest, covering both clinical and basic science topics in gastrointestinal function and disorders. The contents of each issue are comprehensive and reflect the state of the art, featuring editorials, reviews, mini reviews and original papers. These individual contributions encompass a variety of disciplines including all fields of gastroenterology. ''Digestive Diseases'' bridges the communication gap between advances made in the academic setting and their application in patient care. The journal is a valuable service for clinicians, specialists and physicians-in-training.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信