Eic Ju Lim , Jae-Woo Cho , Oog-Jin Shon , Jong-Keon Oh , Kyu Tae Hwang , Gwang Chul Lee
{"title":"远皮质锁定结构用于固定亚洲人的股骨远端骨折:前瞻性观察研究","authors":"Eic Ju Lim , Jae-Woo Cho , Oog-Jin Shon , Jong-Keon Oh , Kyu Tae Hwang , Gwang Chul Lee","doi":"10.1016/j.jos.2024.03.007","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>The stiffness of locked plates suppresses healing process, prompting the introduction of far cortical locking to address this issue. This study aimed to demonstrate the clinical efficacy of far cortical locking constructs in treating distal femoral fractures in an Asian population.</div></div><div><h3>Methods</h3><div>This multicenter prospective observational study was conducted at four university hospitals between February 2018 and February 2021. Demographic data, the presence of metaphyseal comminution, and surgical fixation details were recorded. Clinical outcomes, including single-leg standing, EQ-5D, and EQ-VAS scores, and radiologic outcomes, including the RUST score of each cortex, were evaluated and compared according to the presence of metaphyseal comminution.</div></div><div><h3>Results</h3><div>There were 37 patients (14 men and 23 women) with a mean age of 67.3 ± 11.8 years. Twenty-two patients had metaphyseal comminution (59%), and 15 presented simple fractures in metaphyseal areas. Four patients (13%) could stand on one leg >10s at 6 weeks, and 24 patients (92%) at 1 year. EQ-5D increased from 0.022 ± 0.388 to 0.692 ± 0.347, and the mean EQ-VAS 51.1 ± 13.1 to 74.1 ± 24.1 between discharge (n = 37) and post-operative 1 year (n = 33), respectively. RUST score presented increment for time, from 6.2 ± 1.8 at 6 week to 11.6 ± 1.1 at 1 year. Radiological healing demonstrated rapid increase from week 6 (16/28, 43%) to month 3 (27/31, 87%), with no obvious increase was observed in 6 months (23/26, 89%) or 12 months (25/28, 89%). Simple metaphyseal fractures presented significantly higher RUST scores at 6 weeks and 3 months, but there was no difference in RUST scores at 6 months or 1 year according to metaphyseal comminution.</div></div><div><h3>Conclusions</h3><div>Plate constructs with far cortical locking screws provided safe and effective fixation for distal femoral fractures, with consistent radiological and clinical results, regardless of metaphyseal comminution.</div></div>","PeriodicalId":16939,"journal":{"name":"Journal of Orthopaedic Science","volume":"30 2","pages":"Pages 372-378"},"PeriodicalIF":1.5000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Far cortical locking constructs for fixation of distal femur fractures in an Asian population: A prospective observational study\",\"authors\":\"Eic Ju Lim , Jae-Woo Cho , Oog-Jin Shon , Jong-Keon Oh , Kyu Tae Hwang , Gwang Chul Lee\",\"doi\":\"10.1016/j.jos.2024.03.007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><div>The stiffness of locked plates suppresses healing process, prompting the introduction of far cortical locking to address this issue. This study aimed to demonstrate the clinical efficacy of far cortical locking constructs in treating distal femoral fractures in an Asian population.</div></div><div><h3>Methods</h3><div>This multicenter prospective observational study was conducted at four university hospitals between February 2018 and February 2021. Demographic data, the presence of metaphyseal comminution, and surgical fixation details were recorded. Clinical outcomes, including single-leg standing, EQ-5D, and EQ-VAS scores, and radiologic outcomes, including the RUST score of each cortex, were evaluated and compared according to the presence of metaphyseal comminution.</div></div><div><h3>Results</h3><div>There were 37 patients (14 men and 23 women) with a mean age of 67.3 ± 11.8 years. Twenty-two patients had metaphyseal comminution (59%), and 15 presented simple fractures in metaphyseal areas. Four patients (13%) could stand on one leg >10s at 6 weeks, and 24 patients (92%) at 1 year. EQ-5D increased from 0.022 ± 0.388 to 0.692 ± 0.347, and the mean EQ-VAS 51.1 ± 13.1 to 74.1 ± 24.1 between discharge (n = 37) and post-operative 1 year (n = 33), respectively. RUST score presented increment for time, from 6.2 ± 1.8 at 6 week to 11.6 ± 1.1 at 1 year. Radiological healing demonstrated rapid increase from week 6 (16/28, 43%) to month 3 (27/31, 87%), with no obvious increase was observed in 6 months (23/26, 89%) or 12 months (25/28, 89%). Simple metaphyseal fractures presented significantly higher RUST scores at 6 weeks and 3 months, but there was no difference in RUST scores at 6 months or 1 year according to metaphyseal comminution.</div></div><div><h3>Conclusions</h3><div>Plate constructs with far cortical locking screws provided safe and effective fixation for distal femoral fractures, with consistent radiological and clinical results, regardless of metaphyseal comminution.</div></div>\",\"PeriodicalId\":16939,\"journal\":{\"name\":\"Journal of Orthopaedic Science\",\"volume\":\"30 2\",\"pages\":\"Pages 372-378\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2025-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orthopaedic Science\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0949265824000526\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Science","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0949265824000526","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Far cortical locking constructs for fixation of distal femur fractures in an Asian population: A prospective observational study
Background
The stiffness of locked plates suppresses healing process, prompting the introduction of far cortical locking to address this issue. This study aimed to demonstrate the clinical efficacy of far cortical locking constructs in treating distal femoral fractures in an Asian population.
Methods
This multicenter prospective observational study was conducted at four university hospitals between February 2018 and February 2021. Demographic data, the presence of metaphyseal comminution, and surgical fixation details were recorded. Clinical outcomes, including single-leg standing, EQ-5D, and EQ-VAS scores, and radiologic outcomes, including the RUST score of each cortex, were evaluated and compared according to the presence of metaphyseal comminution.
Results
There were 37 patients (14 men and 23 women) with a mean age of 67.3 ± 11.8 years. Twenty-two patients had metaphyseal comminution (59%), and 15 presented simple fractures in metaphyseal areas. Four patients (13%) could stand on one leg >10s at 6 weeks, and 24 patients (92%) at 1 year. EQ-5D increased from 0.022 ± 0.388 to 0.692 ± 0.347, and the mean EQ-VAS 51.1 ± 13.1 to 74.1 ± 24.1 between discharge (n = 37) and post-operative 1 year (n = 33), respectively. RUST score presented increment for time, from 6.2 ± 1.8 at 6 week to 11.6 ± 1.1 at 1 year. Radiological healing demonstrated rapid increase from week 6 (16/28, 43%) to month 3 (27/31, 87%), with no obvious increase was observed in 6 months (23/26, 89%) or 12 months (25/28, 89%). Simple metaphyseal fractures presented significantly higher RUST scores at 6 weeks and 3 months, but there was no difference in RUST scores at 6 months or 1 year according to metaphyseal comminution.
Conclusions
Plate constructs with far cortical locking screws provided safe and effective fixation for distal femoral fractures, with consistent radiological and clinical results, regardless of metaphyseal comminution.
期刊介绍:
The Journal of Orthopaedic Science is the official peer-reviewed journal of the Japanese Orthopaedic Association. The journal publishes the latest researches and topical debates in all fields of clinical and experimental orthopaedics, including musculoskeletal medicine, sports medicine, locomotive syndrome, trauma, paediatrics, oncology and biomaterials, as well as basic researches.