左束支起搏和双心室起搏的心室不同步成像、超声心动图和临床结果。

Q3 Medicine
Auke A.A. Verstappen , Rick Hautvast , Pavel Jurak , Frank A. Bracke , Leonard M. Rademakers
{"title":"左束支起搏和双心室起搏的心室不同步成像、超声心动图和临床结果。","authors":"Auke A.A. Verstappen ,&nbsp;Rick Hautvast ,&nbsp;Pavel Jurak ,&nbsp;Frank A. Bracke ,&nbsp;Leonard M. Rademakers","doi":"10.1016/j.ipej.2024.04.007","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Left bundle branch pacing (LBBP) is a novel physiological pacing technique which may serve as an alternative to cardiac resynchronization therapy (CRT) by biventricular pacing (BVP). This study assessed ventricular activation patterns and echocardiographic and clinical outcomes of LBBP and compared this to BVP.</p></div><div><h3>Methods</h3><p>Fifty consecutive patients underwent LBBP or BVP for CRT. Ventricular activation mapping was obtained by ultra-high-frequency ECG (UHF-ECG). Functional and echocardiographic outcomes and hospitalization for heart failure and all-cause mortality after one year from implantation were evaluated.</p></div><div><h3>Results</h3><p>LBBP resulted in greater resynchronization vs BVP (QRS width: 170 ± 16 ms to 128 ± 20 ms vs 174 ± 15 to 144 ± 17 ms, <em>p</em> = 0.002 (LBBP vs BVP); e-DYS 81 ± 17 ms to 0 ± 32 ms vs 77 ± 18 to 16 ± 29 ms, <em>p</em> = 0.016 (LBBP vs BVP)). Improvement in LVEF (from 28 ± 8 to 42 ± 10 percent vs 28 ± 9 to 36 ± 12 percent, LBBP vs BVP, <em>p</em> = 0.078) was similar. Improvement in NYHA function class (from 2.4 to 1.5 and from 2.3 to 1.5 (LBBP vs BVP)), hospitalization for heart failure and all-cause mortality were comparable in both groups.</p></div><div><h3>Conclusions</h3><p>Ventricular dyssynchrony imaging is an appropriate way to gain a better insight into activation patterns of LBBP and BVP. LBBP resulted in greater resynchronization (e-DYS and QRS duration) with comparable improvement in LVEF, NYHA functional class, hospitalization for heart failure and all-cause mortality at one year of follow up.</p></div>","PeriodicalId":35900,"journal":{"name":"Indian Pacing and Electrophysiology Journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0972629224000470/pdfft?md5=cfe460e0111c8761d58cc1787a6cf1e0&pid=1-s2.0-S0972629224000470-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Ventricular dyssynchrony imaging, echocardiographic and clinical outcomes of left bundle branch pacing and biventricular pacing\",\"authors\":\"Auke A.A. Verstappen ,&nbsp;Rick Hautvast ,&nbsp;Pavel Jurak ,&nbsp;Frank A. Bracke ,&nbsp;Leonard M. Rademakers\",\"doi\":\"10.1016/j.ipej.2024.04.007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Left bundle branch pacing (LBBP) is a novel physiological pacing technique which may serve as an alternative to cardiac resynchronization therapy (CRT) by biventricular pacing (BVP). This study assessed ventricular activation patterns and echocardiographic and clinical outcomes of LBBP and compared this to BVP.</p></div><div><h3>Methods</h3><p>Fifty consecutive patients underwent LBBP or BVP for CRT. Ventricular activation mapping was obtained by ultra-high-frequency ECG (UHF-ECG). Functional and echocardiographic outcomes and hospitalization for heart failure and all-cause mortality after one year from implantation were evaluated.</p></div><div><h3>Results</h3><p>LBBP resulted in greater resynchronization vs BVP (QRS width: 170 ± 16 ms to 128 ± 20 ms vs 174 ± 15 to 144 ± 17 ms, <em>p</em> = 0.002 (LBBP vs BVP); e-DYS 81 ± 17 ms to 0 ± 32 ms vs 77 ± 18 to 16 ± 29 ms, <em>p</em> = 0.016 (LBBP vs BVP)). Improvement in LVEF (from 28 ± 8 to 42 ± 10 percent vs 28 ± 9 to 36 ± 12 percent, LBBP vs BVP, <em>p</em> = 0.078) was similar. Improvement in NYHA function class (from 2.4 to 1.5 and from 2.3 to 1.5 (LBBP vs BVP)), hospitalization for heart failure and all-cause mortality were comparable in both groups.</p></div><div><h3>Conclusions</h3><p>Ventricular dyssynchrony imaging is an appropriate way to gain a better insight into activation patterns of LBBP and BVP. LBBP resulted in greater resynchronization (e-DYS and QRS duration) with comparable improvement in LVEF, NYHA functional class, hospitalization for heart failure and all-cause mortality at one year of follow up.</p></div>\",\"PeriodicalId\":35900,\"journal\":{\"name\":\"Indian Pacing and Electrophysiology Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0972629224000470/pdfft?md5=cfe460e0111c8761d58cc1787a6cf1e0&pid=1-s2.0-S0972629224000470-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Pacing and Electrophysiology Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0972629224000470\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Pacing and Electrophysiology Journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0972629224000470","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

背景左束支起搏(LBBP)是一种新型生理起搏技术,可作为双室起搏(BVP)心脏再同步化治疗(CRT)的替代方法。这项研究评估了 LBBP 的心室激活模式、超声心动图和临床结果,并将其与 BVP 进行了比较。通过超高频心电图(UHF-ECG)获得心室活化图。结果LBBP与BVP相比,其再同步化程度更高(QRS宽度:170±16 ms至128±20 ms vs 174±15 至144±17 ms,p = 0.002(LBBP vs BVP);e-DYS 81±17 ms至0±32 ms vs 77±18 至16±29 ms,p = 0.016(LBBP vs BVP))。LVEF 的改善(从 28 ± 8% 到 42 ± 10% vs 28 ± 9% 到 36 ± 12%,LBBP vs BVP,p = 0.078)相似。两组患者的 NYHA 功能分级(从 2.4 降至 1.5 和从 2.3 降至 1.5(LBBP vs BVP))、心衰住院率和全因死亡率的改善程度相当。随访一年后,LBBP 会导致更大程度的再同步化(e-DYS 和 QRS 持续时间),而 LVEF、NYHA 功能分级、心衰住院率和全因死亡率的改善程度相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Ventricular dyssynchrony imaging, echocardiographic and clinical outcomes of left bundle branch pacing and biventricular pacing

Background

Left bundle branch pacing (LBBP) is a novel physiological pacing technique which may serve as an alternative to cardiac resynchronization therapy (CRT) by biventricular pacing (BVP). This study assessed ventricular activation patterns and echocardiographic and clinical outcomes of LBBP and compared this to BVP.

Methods

Fifty consecutive patients underwent LBBP or BVP for CRT. Ventricular activation mapping was obtained by ultra-high-frequency ECG (UHF-ECG). Functional and echocardiographic outcomes and hospitalization for heart failure and all-cause mortality after one year from implantation were evaluated.

Results

LBBP resulted in greater resynchronization vs BVP (QRS width: 170 ± 16 ms to 128 ± 20 ms vs 174 ± 15 to 144 ± 17 ms, p = 0.002 (LBBP vs BVP); e-DYS 81 ± 17 ms to 0 ± 32 ms vs 77 ± 18 to 16 ± 29 ms, p = 0.016 (LBBP vs BVP)). Improvement in LVEF (from 28 ± 8 to 42 ± 10 percent vs 28 ± 9 to 36 ± 12 percent, LBBP vs BVP, p = 0.078) was similar. Improvement in NYHA function class (from 2.4 to 1.5 and from 2.3 to 1.5 (LBBP vs BVP)), hospitalization for heart failure and all-cause mortality were comparable in both groups.

Conclusions

Ventricular dyssynchrony imaging is an appropriate way to gain a better insight into activation patterns of LBBP and BVP. LBBP resulted in greater resynchronization (e-DYS and QRS duration) with comparable improvement in LVEF, NYHA functional class, hospitalization for heart failure and all-cause mortality at one year of follow up.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Indian Pacing and Electrophysiology Journal
Indian Pacing and Electrophysiology Journal Medicine-Cardiology and Cardiovascular Medicine
CiteScore
2.20
自引率
0.00%
发文量
91
审稿时长
61 days
期刊介绍: Indian Pacing and Electrophysiology Journal is a peer reviewed online journal devoted to cardiac pacing and electrophysiology. Editorial Advisory Board includes eminent personalities in the field of cardiac pacing and electrophysiology from Asia, Australia, Europe and North America.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信