主动脉生物假体的体外流体动力学特性:新旧对比。

Y R Woo, H W Sung, F P Williams, A P Yoganathan
{"title":"主动脉生物假体的体外流体动力学特性:新旧对比。","authors":"Y R Woo,&nbsp;H W Sung,&nbsp;F P Williams,&nbsp;A P Yoganathan","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The in vitro fluid dynamic characteristics of a variety of old- and new-generation porcine and pericardial aortic bioprostheses were investigated under pulsatile flow conditions. The pressure drop results indicate that the old valve designs have performance indices in the range of 0.30 to 0.42, while the new, low-pressure fixed designs have performance indices of 0.50 to 0.70. Leaflet photography indicated that the new designs also have superior opening and closing characteristics. Flow visualization, and velocity and turbulent shear stress measurements, conducted with a two-dimensional laser Doppler anemometer system, indicated that all the tissue valve designs create jet-type flow fields. The intensity of the jets and turbulence levels were less severe with the new designs. The old designs created turbulent shear stresses of as little as 1500 dynes/cm2, while the new designs created turbulent shear stresses of as little as 750 dynes/cm2.</p>","PeriodicalId":77869,"journal":{"name":"Life support systems : the journal of the European Society for Artificial Organs","volume":"4 1","pages":"63-85"},"PeriodicalIF":0.0000,"publicationDate":"1986-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In vitro fluid dynamic characteristics of aortic bioprostheses: old versus new.\",\"authors\":\"Y R Woo,&nbsp;H W Sung,&nbsp;F P Williams,&nbsp;A P Yoganathan\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The in vitro fluid dynamic characteristics of a variety of old- and new-generation porcine and pericardial aortic bioprostheses were investigated under pulsatile flow conditions. The pressure drop results indicate that the old valve designs have performance indices in the range of 0.30 to 0.42, while the new, low-pressure fixed designs have performance indices of 0.50 to 0.70. Leaflet photography indicated that the new designs also have superior opening and closing characteristics. Flow visualization, and velocity and turbulent shear stress measurements, conducted with a two-dimensional laser Doppler anemometer system, indicated that all the tissue valve designs create jet-type flow fields. The intensity of the jets and turbulence levels were less severe with the new designs. The old designs created turbulent shear stresses of as little as 1500 dynes/cm2, while the new designs created turbulent shear stresses of as little as 750 dynes/cm2.</p>\",\"PeriodicalId\":77869,\"journal\":{\"name\":\"Life support systems : the journal of the European Society for Artificial Organs\",\"volume\":\"4 1\",\"pages\":\"63-85\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1986-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Life support systems : the journal of the European Society for Artificial Organs\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Life support systems : the journal of the European Society for Artificial Organs","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研究了不同新旧一代猪心包主动脉生物假体在脉动血流条件下的体外流体动力学特性。压降结果表明,旧阀设计的性能指标在0.30 ~ 0.42之间,而新的低压固定阀设计的性能指标在0.50 ~ 0.70之间。传单摄影表明,新设计还具有优越的启闭特性。利用二维激光多普勒风速仪系统进行的流动可视化、速度和湍流剪切应力测量表明,所有组织阀设计都产生了射流型流场。新设计的飞机的喷射强度和湍流水平都没有那么严重。旧设计产生的湍流剪切应力低至1500达因/平方厘米,而新设计产生的湍流剪切应力低至750达因/平方厘米。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
In vitro fluid dynamic characteristics of aortic bioprostheses: old versus new.

The in vitro fluid dynamic characteristics of a variety of old- and new-generation porcine and pericardial aortic bioprostheses were investigated under pulsatile flow conditions. The pressure drop results indicate that the old valve designs have performance indices in the range of 0.30 to 0.42, while the new, low-pressure fixed designs have performance indices of 0.50 to 0.70. Leaflet photography indicated that the new designs also have superior opening and closing characteristics. Flow visualization, and velocity and turbulent shear stress measurements, conducted with a two-dimensional laser Doppler anemometer system, indicated that all the tissue valve designs create jet-type flow fields. The intensity of the jets and turbulence levels were less severe with the new designs. The old designs created turbulent shear stresses of as little as 1500 dynes/cm2, while the new designs created turbulent shear stresses of as little as 750 dynes/cm2.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信