{"title":"供热网络低温区的年平均水温","authors":"D. Kitaev, A. R. Bohan","doi":"10.21869/2223-1560-2024-28-1-44-56","DOIUrl":null,"url":null,"abstract":"Purpose of research. For settlements located in the permafrost zone on the territory of the Russian Federation, obtain the values of average annual water temperatures in heating networks of centralized heating systems separately for the supply and return mains using design water temperatures in the range from 95 to 150 ° C, taking into account modern climatic data and the indicators of the heating systems used devices.Methods. To achieve the set goals, methods of central high-quality regulation of the load of the thermal energy consumer were used, based on the heat balance equation. To find the temperatures at the break point of the temperature graph, numerical methods for solving equations were used. To obtain an equation for the dependence of the average annual water temperature in the supply main of the heating network, methods of the theory of approximation of functions by algebraic polynomials were used. To cluster settlements according to the criterion of being in the permafrost zone and the possibility of using centralized heat supply, methods of analysis and synthesis were used.Results. Average annual water temperatures for the supply and return lines of heating networks were obtained using central quality control schedules with design temperatures from 95 to 150°C, taking into account the values of average monthly outdoor air temperatures for settlements in the permafrost zone of the Russian Federation.Conclusion. The values of annual water temperatures recommended by modern standards for the supply main of heating networks may differ significantly from the calculated values obtained taking into account the design water temperatures, climatic characteristics of the design area, and features of the organization of a closed heat supply system in order to ensure standard hot water supply temperatures. A quadratic equation has been obtained that makes it possible to calculate with high accuracy the design annual temperature of the coolant for the supply pipeline depending on the temperature schedule implemented in the heat supply system for settlements located in the permafrost zone.","PeriodicalId":443878,"journal":{"name":"Proceedings of the Southwest State University","volume":"10 19","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Average Annual Water Temperatures in Heating Networks Cryolithozones\",\"authors\":\"D. Kitaev, A. R. Bohan\",\"doi\":\"10.21869/2223-1560-2024-28-1-44-56\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose of research. For settlements located in the permafrost zone on the territory of the Russian Federation, obtain the values of average annual water temperatures in heating networks of centralized heating systems separately for the supply and return mains using design water temperatures in the range from 95 to 150 ° C, taking into account modern climatic data and the indicators of the heating systems used devices.Methods. To achieve the set goals, methods of central high-quality regulation of the load of the thermal energy consumer were used, based on the heat balance equation. To find the temperatures at the break point of the temperature graph, numerical methods for solving equations were used. To obtain an equation for the dependence of the average annual water temperature in the supply main of the heating network, methods of the theory of approximation of functions by algebraic polynomials were used. To cluster settlements according to the criterion of being in the permafrost zone and the possibility of using centralized heat supply, methods of analysis and synthesis were used.Results. Average annual water temperatures for the supply and return lines of heating networks were obtained using central quality control schedules with design temperatures from 95 to 150°C, taking into account the values of average monthly outdoor air temperatures for settlements in the permafrost zone of the Russian Federation.Conclusion. The values of annual water temperatures recommended by modern standards for the supply main of heating networks may differ significantly from the calculated values obtained taking into account the design water temperatures, climatic characteristics of the design area, and features of the organization of a closed heat supply system in order to ensure standard hot water supply temperatures. A quadratic equation has been obtained that makes it possible to calculate with high accuracy the design annual temperature of the coolant for the supply pipeline depending on the temperature schedule implemented in the heat supply system for settlements located in the permafrost zone.\",\"PeriodicalId\":443878,\"journal\":{\"name\":\"Proceedings of the Southwest State University\",\"volume\":\"10 19\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Southwest State University\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21869/2223-1560-2024-28-1-44-56\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Southwest State University","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21869/2223-1560-2024-28-1-44-56","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研究目的。对于位于俄罗斯联邦境内永久冻土带的居民点,考虑到现代气候数据和供热系统所用设备的指标,分别得出集中供热系统供热网络中的供热和回水干管的年平均水温值,设计水温范围为 95 至 150 °C。为实现既定目标,采用了基于热平衡方程的热能消费者负荷中央高质量调节方法。为了找到温度图断点处的温度,使用了数值解方程方法。为了获得供热管网中年平均水温的相关方程,使用了代数多项式函数近似理论方法。为了根据位于永久冻土区的标准和使用集中供热的可能性对居民点进行分组,使用了分析和综合的方法。考虑到俄罗斯联邦永久冻土区居民点的月平均室外气温值,利用设计温度为 95 至 150°C 的中央质量控制表,得出了供热管网供水管道和回水管的年平均水温。现代标准推荐的供热管网的年水温值可能与计算值有很大差异,计算值考虑了设计水温、设计区域的气候特征以及封闭式供热系统的组织特点,以确保标准的热水供应温度。根据位于永久冻土区的居民点供热系统所采用的温度表,可以得到一个二次方程,从而可以非常准确地计算出供水管道冷却剂的设计年温度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Average Annual Water Temperatures in Heating Networks Cryolithozones
Purpose of research. For settlements located in the permafrost zone on the territory of the Russian Federation, obtain the values of average annual water temperatures in heating networks of centralized heating systems separately for the supply and return mains using design water temperatures in the range from 95 to 150 ° C, taking into account modern climatic data and the indicators of the heating systems used devices.Methods. To achieve the set goals, methods of central high-quality regulation of the load of the thermal energy consumer were used, based on the heat balance equation. To find the temperatures at the break point of the temperature graph, numerical methods for solving equations were used. To obtain an equation for the dependence of the average annual water temperature in the supply main of the heating network, methods of the theory of approximation of functions by algebraic polynomials were used. To cluster settlements according to the criterion of being in the permafrost zone and the possibility of using centralized heat supply, methods of analysis and synthesis were used.Results. Average annual water temperatures for the supply and return lines of heating networks were obtained using central quality control schedules with design temperatures from 95 to 150°C, taking into account the values of average monthly outdoor air temperatures for settlements in the permafrost zone of the Russian Federation.Conclusion. The values of annual water temperatures recommended by modern standards for the supply main of heating networks may differ significantly from the calculated values obtained taking into account the design water temperatures, climatic characteristics of the design area, and features of the organization of a closed heat supply system in order to ensure standard hot water supply temperatures. A quadratic equation has been obtained that makes it possible to calculate with high accuracy the design annual temperature of the coolant for the supply pipeline depending on the temperature schedule implemented in the heat supply system for settlements located in the permafrost zone.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信