利用三维打印面部模型为伊拉克外科医生提供腮腺切除术手术模拟和教育

Q3 Health Professions
Hassanain Ali Lafta, Ali Adel Madlol
{"title":"利用三维打印面部模型为伊拉克外科医生提供腮腺切除术手术模拟和教育","authors":"Hassanain Ali Lafta, Ali Adel Madlol","doi":"10.18502/fbt.v11i2.15331","DOIUrl":null,"url":null,"abstract":"Purpose: Parotidectomy is usually suggested for many persons with parotid gland tumors. Facial nerve weakening is the most concerning of the potential consequences related to parotidectomy, resulting in a significantly reduced patient quality of life. With preoperative preparation and surgical training and simulation, a three-Dimensional (3D) printed human face anatomical model has just been designed and fabricated. \nMaterials and Methods: Fifteen surgeons from Iraqi teaching hospitals evaluated the simulator model by using a Likert scale survey. The model is composed of a silicon based human face replica with an incorporated parotid gland replica and a closed electrical circuit of the facial nerve course to show when contact is made between the surgical instrument and the nerve to provide feedback. \nResults and Conclusion: All participants gave favorable feedback. Significant levels of satisfaction with the designed simulator have been relatively achieved. In comparison to experts, novice surgeons scored less for skin realism and handling. Such a difference suggests that the proposed simulator appears to have the potential to contribute to the advancement of surgical simulation, education, and planning.","PeriodicalId":34203,"journal":{"name":"Frontiers in Biomedical Technologies","volume":"37 8","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Parotidectomy Surgical Simulation and Education with a Three-Dimensional Printed Face Model for Iraqi Surgeons\",\"authors\":\"Hassanain Ali Lafta, Ali Adel Madlol\",\"doi\":\"10.18502/fbt.v11i2.15331\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose: Parotidectomy is usually suggested for many persons with parotid gland tumors. Facial nerve weakening is the most concerning of the potential consequences related to parotidectomy, resulting in a significantly reduced patient quality of life. With preoperative preparation and surgical training and simulation, a three-Dimensional (3D) printed human face anatomical model has just been designed and fabricated. \\nMaterials and Methods: Fifteen surgeons from Iraqi teaching hospitals evaluated the simulator model by using a Likert scale survey. The model is composed of a silicon based human face replica with an incorporated parotid gland replica and a closed electrical circuit of the facial nerve course to show when contact is made between the surgical instrument and the nerve to provide feedback. \\nResults and Conclusion: All participants gave favorable feedback. Significant levels of satisfaction with the designed simulator have been relatively achieved. In comparison to experts, novice surgeons scored less for skin realism and handling. Such a difference suggests that the proposed simulator appears to have the potential to contribute to the advancement of surgical simulation, education, and planning.\",\"PeriodicalId\":34203,\"journal\":{\"name\":\"Frontiers in Biomedical Technologies\",\"volume\":\"37 8\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Frontiers in Biomedical Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18502/fbt.v11i2.15331\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Health Professions\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Biomedical Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/fbt.v11i2.15331","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0

摘要

目的:许多腮腺肿瘤患者通常会被建议进行腮腺切除术。面神经功能减弱是腮腺切除术最令人担忧的潜在后果,会导致患者生活质量显著下降。通过术前准备、手术培训和模拟,我们刚刚设计并制作了一个三维(3D)打印人脸解剖模型。材料和方法:来自伊拉克教学医院的 15 名外科医生通过李克特量表调查对模拟器模型进行了评估。该模型由一个基于硅的人脸复制品组成,其中包含一个腮腺复制品和一个面部神经闭合电路,用于显示手术器械与神经接触时的反馈信息。结果和结论:所有参与者都给予了好评。对所设计模拟器的满意度相对较高。与专家相比,外科医生新手在皮肤逼真度和操作方面的得分较低。这种差异表明,所提议的模拟器似乎有潜力为手术模拟、教育和规划的进步做出贡献。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Parotidectomy Surgical Simulation and Education with a Three-Dimensional Printed Face Model for Iraqi Surgeons
Purpose: Parotidectomy is usually suggested for many persons with parotid gland tumors. Facial nerve weakening is the most concerning of the potential consequences related to parotidectomy, resulting in a significantly reduced patient quality of life. With preoperative preparation and surgical training and simulation, a three-Dimensional (3D) printed human face anatomical model has just been designed and fabricated. Materials and Methods: Fifteen surgeons from Iraqi teaching hospitals evaluated the simulator model by using a Likert scale survey. The model is composed of a silicon based human face replica with an incorporated parotid gland replica and a closed electrical circuit of the facial nerve course to show when contact is made between the surgical instrument and the nerve to provide feedback. Results and Conclusion: All participants gave favorable feedback. Significant levels of satisfaction with the designed simulator have been relatively achieved. In comparison to experts, novice surgeons scored less for skin realism and handling. Such a difference suggests that the proposed simulator appears to have the potential to contribute to the advancement of surgical simulation, education, and planning.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Frontiers in Biomedical Technologies
Frontiers in Biomedical Technologies Health Professions-Medical Laboratory Technology
CiteScore
0.80
自引率
0.00%
发文量
34
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信