{"title":"受限砌体结构中横向荷载的拉结柱设计","authors":"Bonisha Borah, Akshay Gupta, V. Singhal, H. Kaushik","doi":"10.1177/87552930241246148","DOIUrl":null,"url":null,"abstract":"Confined masonry (CM) buildings are generally designed with an expectation that masonry walls withstand all possible loads imparted on the buildings. The reinforced concrete (RC) confining members, also known as tie-members, have the sole purpose of constraining the masonry and avoiding its outward spread during lateral earthquake loading. Reliable design rules for tie-columns are scarce in design codes of CM structures, often resulting in the nominal design of tie-elements without considering the influence of all the important parameters related to the material and geometric properties of CM wall. This often results in the construction of weaker tie-members, especially the tie-columns, that can lead to their direct failure and the failure of the entire wall during earthquakes. To address this issue, a methodology was developed for assessing the design shear forces for the tie-columns as well as masonry subjected to lateral loading by utilizing the past observations from systematic experimental and numerical studies. The efficacy of this methodology was evaluated in the present experimental study conducted on CM walls with varying aspect ratios. The test results demonstrated that the proposed methodology can result in a significant improvement in the lateral load behavior of CM walls, by delaying the shear failure of tie-columns without jeopardizing other functional requirements.","PeriodicalId":505879,"journal":{"name":"Earthquake Spectra","volume":"6 6","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design of tie-columns in confined masonry structures for lateral loads\",\"authors\":\"Bonisha Borah, Akshay Gupta, V. Singhal, H. Kaushik\",\"doi\":\"10.1177/87552930241246148\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Confined masonry (CM) buildings are generally designed with an expectation that masonry walls withstand all possible loads imparted on the buildings. The reinforced concrete (RC) confining members, also known as tie-members, have the sole purpose of constraining the masonry and avoiding its outward spread during lateral earthquake loading. Reliable design rules for tie-columns are scarce in design codes of CM structures, often resulting in the nominal design of tie-elements without considering the influence of all the important parameters related to the material and geometric properties of CM wall. This often results in the construction of weaker tie-members, especially the tie-columns, that can lead to their direct failure and the failure of the entire wall during earthquakes. To address this issue, a methodology was developed for assessing the design shear forces for the tie-columns as well as masonry subjected to lateral loading by utilizing the past observations from systematic experimental and numerical studies. The efficacy of this methodology was evaluated in the present experimental study conducted on CM walls with varying aspect ratios. The test results demonstrated that the proposed methodology can result in a significant improvement in the lateral load behavior of CM walls, by delaying the shear failure of tie-columns without jeopardizing other functional requirements.\",\"PeriodicalId\":505879,\"journal\":{\"name\":\"Earthquake Spectra\",\"volume\":\"6 6\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Earthquake Spectra\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/87552930241246148\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Earthquake Spectra","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/87552930241246148","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

封闭式砌体(CM)建筑的设计通常希望砌体墙能够承受建筑物可能承受的所有荷载。钢筋混凝土(RC)约束构件(也称拉杆构件)的唯一作用是约束砌体,避免其在地震侧向荷载作用下向外扩展。在 CM 结构的设计规范中,缺少可靠的拉结柱设计规则,这往往导致拉结构件的名义设计没有考虑到与 CM 墙体材料和几何特性相关的所有重要参数的影响。这通常会导致拉结构件(尤其是拉结柱)的强度降低,从而在地震中直接导致拉结构件失效和整个墙体失效。为解决这一问题,我们开发了一种方法,利用过去系统实验和数值研究的观察结果,评估承受横向荷载的拉结柱和砌体的设计剪力。在本实验研究中,对不同长宽比的 CM 墙进行了评估。测试结果表明,所建议的方法可通过延迟拉结柱的剪切破坏而显著改善 CM 墙的横向荷载行为,同时不会影响其他功能要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design of tie-columns in confined masonry structures for lateral loads
Confined masonry (CM) buildings are generally designed with an expectation that masonry walls withstand all possible loads imparted on the buildings. The reinforced concrete (RC) confining members, also known as tie-members, have the sole purpose of constraining the masonry and avoiding its outward spread during lateral earthquake loading. Reliable design rules for tie-columns are scarce in design codes of CM structures, often resulting in the nominal design of tie-elements without considering the influence of all the important parameters related to the material and geometric properties of CM wall. This often results in the construction of weaker tie-members, especially the tie-columns, that can lead to their direct failure and the failure of the entire wall during earthquakes. To address this issue, a methodology was developed for assessing the design shear forces for the tie-columns as well as masonry subjected to lateral loading by utilizing the past observations from systematic experimental and numerical studies. The efficacy of this methodology was evaluated in the present experimental study conducted on CM walls with varying aspect ratios. The test results demonstrated that the proposed methodology can result in a significant improvement in the lateral load behavior of CM walls, by delaying the shear failure of tie-columns without jeopardizing other functional requirements.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信