用于直接分子检测血液中假马勒伯克霍尔德氏菌的 DNA 提取方法比较

Georgia Mataira, Fleur Francis, Jaimie Frazer, Robert Norton
{"title":"用于直接分子检测血液中假马勒伯克霍尔德氏菌的 DNA 提取方法比较","authors":"Georgia Mataira, Fleur Francis, Jaimie Frazer, Robert Norton","doi":"10.1093/trstmh/trae020","DOIUrl":null,"url":null,"abstract":"Background Melioidosis is caused by Burkholderia pseudomallei. Direct molecular detection from unamplified blood remains insensitive. Methods Three different extraction methods—QIAamp UCP Pathogen Mini Kit, High Pure PCR template and MagNA Pure Pathogen Universal—were trialled using spiked human ethylenediaminetetraacetic acid blood. A type III secretion system 1 (TTSS-1) polymerase chain reaction was used for detection. Results The QIAamp UCP Pathogen Mini Kit performed best, with a limit of detection of 1.5×102 cfu/ml. Conclusions It is planned to use the QIAamp UCP Pathogen Mini Kit to do a larger study on blood collected from patients with melioidosis.","PeriodicalId":501685,"journal":{"name":"Transactions of the Royal Society of Tropical Medicine & Hygiene","volume":"65 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A comparison of DNA extraction methods used in the direct molecular detection of Burkholderia pseudomallei from blood\",\"authors\":\"Georgia Mataira, Fleur Francis, Jaimie Frazer, Robert Norton\",\"doi\":\"10.1093/trstmh/trae020\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background Melioidosis is caused by Burkholderia pseudomallei. Direct molecular detection from unamplified blood remains insensitive. Methods Three different extraction methods—QIAamp UCP Pathogen Mini Kit, High Pure PCR template and MagNA Pure Pathogen Universal—were trialled using spiked human ethylenediaminetetraacetic acid blood. A type III secretion system 1 (TTSS-1) polymerase chain reaction was used for detection. Results The QIAamp UCP Pathogen Mini Kit performed best, with a limit of detection of 1.5×102 cfu/ml. Conclusions It is planned to use the QIAamp UCP Pathogen Mini Kit to do a larger study on blood collected from patients with melioidosis.\",\"PeriodicalId\":501685,\"journal\":{\"name\":\"Transactions of the Royal Society of Tropical Medicine & Hygiene\",\"volume\":\"65 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transactions of the Royal Society of Tropical Medicine & Hygiene\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/trstmh/trae020\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions of the Royal Society of Tropical Medicine & Hygiene","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/trstmh/trae020","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景 Melioidosis 是由假马来伯克霍尔德氏菌(Burkholderia pseudomallei)引起的。从未经扩增的血液中直接进行分子检测仍然不敏感。方法 使用添加了乙二胺四乙酸的人体血液,试用了三种不同的提取方法--QIAamp UCP 病原体迷你试剂盒、高纯度 PCR 模板和 MagNA 纯病原体通用试剂盒。采用 III 型分泌系统 1 (TTSS-1) 聚合酶链反应进行检测。结果 QIAamp UCP 病原体迷你试剂盒性能最佳,检测限为 1.5×102 cfu/ml。结论 计划使用 QIAamp UCP 病原体迷你试剂盒对从类鼻疽患者采集的血液进行更大规模的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A comparison of DNA extraction methods used in the direct molecular detection of Burkholderia pseudomallei from blood
Background Melioidosis is caused by Burkholderia pseudomallei. Direct molecular detection from unamplified blood remains insensitive. Methods Three different extraction methods—QIAamp UCP Pathogen Mini Kit, High Pure PCR template and MagNA Pure Pathogen Universal—were trialled using spiked human ethylenediaminetetraacetic acid blood. A type III secretion system 1 (TTSS-1) polymerase chain reaction was used for detection. Results The QIAamp UCP Pathogen Mini Kit performed best, with a limit of detection of 1.5×102 cfu/ml. Conclusions It is planned to use the QIAamp UCP Pathogen Mini Kit to do a larger study on blood collected from patients with melioidosis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信