{"title":"超声引导下关节穿刺治疗髁状突骨折:技术报告","authors":"Tomoharu Hemmi, Tomohiro Uno, Kazuyuki Yusa, Shigeo Ishikawa, Mitsuyoshi Iino","doi":"10.1007/s11282-024-00744-8","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Objectives</h3><p>Double puncture arthrocentesis (DPA) of the temporomandibular joint (TMD) is considered an effective preservative option for managing mandibular condylar head fractures. However, the procedure is commonly performed by a traditional “blind” method using anatomical characteristics. In the present study, an ultrasonography (US) device was applied for the treatment of a case with a fractured mandibular condyle.</p><h3 data-test=\"abstract-sub-heading\">Methods</h3><p>A 79-year-old female was diagnosed right side condylar head fracture complaining pain of right TMD and reduced mouth opening range: inter-incisor distance of 20 mm. Since the fracture position was high and inoperable, the decision was made to perform DPA of the TMD. The US probe was positioned parallel and slightly oblique to the major axis of the mandibular ramus. Both the posterior and anterior insertions into the joint space were performed according to the axis mentioned above, which enabled the operator to visualize the entirety of the needle.</p><h3 data-test=\"abstract-sub-heading\">Results</h3><p>The device offered safety and ensured accuracy by providing real-time visual aid to the surgeon. The procedure provided an early increase in the inter-incisor distance (31 mm) and pain relief.</p><h3 data-test=\"abstract-sub-heading\">Conclusions</h3><p>Hence, for the preservative treatment of mandibular condylar head fractures, based on the present study, we recommend US-guided arthrocentesis as a safe, feasible, and effective therapeutic option instead of the conventional “blind” method.</p>","PeriodicalId":56103,"journal":{"name":"Oral Radiology","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2024-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ultrasound-guided arthrocentesis for condylar head fracture: a technical report\",\"authors\":\"Tomoharu Hemmi, Tomohiro Uno, Kazuyuki Yusa, Shigeo Ishikawa, Mitsuyoshi Iino\",\"doi\":\"10.1007/s11282-024-00744-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<h3 data-test=\\\"abstract-sub-heading\\\">Objectives</h3><p>Double puncture arthrocentesis (DPA) of the temporomandibular joint (TMD) is considered an effective preservative option for managing mandibular condylar head fractures. However, the procedure is commonly performed by a traditional “blind” method using anatomical characteristics. In the present study, an ultrasonography (US) device was applied for the treatment of a case with a fractured mandibular condyle.</p><h3 data-test=\\\"abstract-sub-heading\\\">Methods</h3><p>A 79-year-old female was diagnosed right side condylar head fracture complaining pain of right TMD and reduced mouth opening range: inter-incisor distance of 20 mm. Since the fracture position was high and inoperable, the decision was made to perform DPA of the TMD. The US probe was positioned parallel and slightly oblique to the major axis of the mandibular ramus. Both the posterior and anterior insertions into the joint space were performed according to the axis mentioned above, which enabled the operator to visualize the entirety of the needle.</p><h3 data-test=\\\"abstract-sub-heading\\\">Results</h3><p>The device offered safety and ensured accuracy by providing real-time visual aid to the surgeon. The procedure provided an early increase in the inter-incisor distance (31 mm) and pain relief.</p><h3 data-test=\\\"abstract-sub-heading\\\">Conclusions</h3><p>Hence, for the preservative treatment of mandibular condylar head fractures, based on the present study, we recommend US-guided arthrocentesis as a safe, feasible, and effective therapeutic option instead of the conventional “blind” method.</p>\",\"PeriodicalId\":56103,\"journal\":{\"name\":\"Oral Radiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-04-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Oral Radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11282-024-00744-8\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oral Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11282-024-00744-8","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Ultrasound-guided arthrocentesis for condylar head fracture: a technical report
Objectives
Double puncture arthrocentesis (DPA) of the temporomandibular joint (TMD) is considered an effective preservative option for managing mandibular condylar head fractures. However, the procedure is commonly performed by a traditional “blind” method using anatomical characteristics. In the present study, an ultrasonography (US) device was applied for the treatment of a case with a fractured mandibular condyle.
Methods
A 79-year-old female was diagnosed right side condylar head fracture complaining pain of right TMD and reduced mouth opening range: inter-incisor distance of 20 mm. Since the fracture position was high and inoperable, the decision was made to perform DPA of the TMD. The US probe was positioned parallel and slightly oblique to the major axis of the mandibular ramus. Both the posterior and anterior insertions into the joint space were performed according to the axis mentioned above, which enabled the operator to visualize the entirety of the needle.
Results
The device offered safety and ensured accuracy by providing real-time visual aid to the surgeon. The procedure provided an early increase in the inter-incisor distance (31 mm) and pain relief.
Conclusions
Hence, for the preservative treatment of mandibular condylar head fractures, based on the present study, we recommend US-guided arthrocentesis as a safe, feasible, and effective therapeutic option instead of the conventional “blind” method.
期刊介绍:
As the official English-language journal of the Japanese Society for Oral and Maxillofacial Radiology and the Asian Academy of Oral and Maxillofacial Radiology, Oral Radiology is intended to be a forum for international collaboration in head and neck diagnostic imaging and all related fields. Oral Radiology features cutting-edge research papers, review articles, case reports, and technical notes from both the clinical and experimental fields. As membership in the Society is not a prerequisite, contributions are welcome from researchers and clinicians worldwide.