重采样策略及其对低采样率心电图数据中心率变异性特征的影响

Muhammad Zakariyah, Umar Zaky, Muhammad Nurjaman, Agil Ghani Istikmal, Hafizh Athallah Widianto
{"title":"重采样策略及其对低采样率心电图数据中心率变异性特征的影响","authors":"Muhammad Zakariyah, Umar Zaky, Muhammad Nurjaman, Agil Ghani Istikmal, Hafizh Athallah Widianto","doi":"10.20895/infotel.v16i1.1049","DOIUrl":null,"url":null,"abstract":"Heart rate variability (HRV) is a parameter to measure fluctuations in the interval between heartbeats. HRV provides essential insights into the cardiovascular function and autonomic nervous system. Electrocardiograms (ECG) on wearable devices are often recorded at low sampling rates, limiting temporal resolution and information. Resampling is a technique of changing the sampling rate from a high sampling rate to a lower sampling rate and vice versa. This research aims to evaluate the effect of resampling ECG data with a low sampling rate on HRV features. ECG data consists of 50 Hz and 100 Hz sampling rates. Data with a 50 Hz sampling rate is up-sampled up to 100 Hz, while 100 Hz data is down-sampled up to 50 Hz and up-sampled up to 250 Hz using the Fast Fourier Transform Interpolation Method. Upsampling from 50 Hz to 100 Hz shows unsatisfactory results, except for some HRV features such as NN20, pNN20, and CVI. Better results were found when up sampling from 100 Hz up to 250 Hz, with some HRV features showing good concordance values. However, downsampling from 100 Hz up to 50 Hz is unsuitable for HRV feature analysis. To obtain accurate HRV analysis results in all domains, it is highly recommended to use a sampling rate above 100 Hz.","PeriodicalId":30672,"journal":{"name":"Jurnal Infotel","volume":"43 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Resampling Strategies and their Influence on Heart Rate Variability Features in Low Sampling Rate Electrocardiogram Data\",\"authors\":\"Muhammad Zakariyah, Umar Zaky, Muhammad Nurjaman, Agil Ghani Istikmal, Hafizh Athallah Widianto\",\"doi\":\"10.20895/infotel.v16i1.1049\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Heart rate variability (HRV) is a parameter to measure fluctuations in the interval between heartbeats. HRV provides essential insights into the cardiovascular function and autonomic nervous system. Electrocardiograms (ECG) on wearable devices are often recorded at low sampling rates, limiting temporal resolution and information. Resampling is a technique of changing the sampling rate from a high sampling rate to a lower sampling rate and vice versa. This research aims to evaluate the effect of resampling ECG data with a low sampling rate on HRV features. ECG data consists of 50 Hz and 100 Hz sampling rates. Data with a 50 Hz sampling rate is up-sampled up to 100 Hz, while 100 Hz data is down-sampled up to 50 Hz and up-sampled up to 250 Hz using the Fast Fourier Transform Interpolation Method. Upsampling from 50 Hz to 100 Hz shows unsatisfactory results, except for some HRV features such as NN20, pNN20, and CVI. Better results were found when up sampling from 100 Hz up to 250 Hz, with some HRV features showing good concordance values. However, downsampling from 100 Hz up to 50 Hz is unsuitable for HRV feature analysis. To obtain accurate HRV analysis results in all domains, it is highly recommended to use a sampling rate above 100 Hz.\",\"PeriodicalId\":30672,\"journal\":{\"name\":\"Jurnal Infotel\",\"volume\":\"43 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Infotel\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.20895/infotel.v16i1.1049\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Infotel","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20895/infotel.v16i1.1049","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

心率变异性(HRV)是测量心跳间隔波动的参数。心率变异可为了解心血管功能和自律神经系统提供重要信息。可穿戴设备上的心电图(ECG)通常以较低的采样率记录,从而限制了时间分辨率和信息量。重采样是一种将采样率从高采样率改为低采样率的技术,反之亦然。本研究旨在评估低采样率重采样心电图数据对心率变异特征的影响。心电图数据包括 50 赫兹和 100 赫兹两种采样率。采用快速傅立叶变换插值法,将 50 赫兹采样率的数据向上采样至 100 赫兹,而将 100 赫兹数据向下采样至 50 赫兹,再向上采样至 250 赫兹。除了一些心率变异特征(如 NN20、pNN20 和 CVI)外,从 50 Hz 升采样到 100 Hz 的结果并不令人满意。将采样频率从 100 Hz 提高到 250 Hz 的结果较好,一些心率变异特征显示出良好的一致性。然而,将采样频率从 100 Hz 降到 50 Hz 并不适合心率变异特征分析。为了在所有领域获得准确的心率变异分析结果,强烈建议使用 100 赫兹以上的采样率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Resampling Strategies and their Influence on Heart Rate Variability Features in Low Sampling Rate Electrocardiogram Data
Heart rate variability (HRV) is a parameter to measure fluctuations in the interval between heartbeats. HRV provides essential insights into the cardiovascular function and autonomic nervous system. Electrocardiograms (ECG) on wearable devices are often recorded at low sampling rates, limiting temporal resolution and information. Resampling is a technique of changing the sampling rate from a high sampling rate to a lower sampling rate and vice versa. This research aims to evaluate the effect of resampling ECG data with a low sampling rate on HRV features. ECG data consists of 50 Hz and 100 Hz sampling rates. Data with a 50 Hz sampling rate is up-sampled up to 100 Hz, while 100 Hz data is down-sampled up to 50 Hz and up-sampled up to 250 Hz using the Fast Fourier Transform Interpolation Method. Upsampling from 50 Hz to 100 Hz shows unsatisfactory results, except for some HRV features such as NN20, pNN20, and CVI. Better results were found when up sampling from 100 Hz up to 250 Hz, with some HRV features showing good concordance values. However, downsampling from 100 Hz up to 50 Hz is unsuitable for HRV feature analysis. To obtain accurate HRV analysis results in all domains, it is highly recommended to use a sampling rate above 100 Hz.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
47
审稿时长
6 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信