丙烯酸补偿滤光片设计可增强颚后投影的 X 射线图像

Mukhtar Effendi, Sri Maryanah, Agus Sholeh, Wiwiek Fatchurohmah
{"title":"丙烯酸补偿滤光片设计可增强颚后投影的 X 射线图像","authors":"Mukhtar Effendi, Sri Maryanah, Agus Sholeh, Wiwiek Fatchurohmah","doi":"10.4028/p-99gfws","DOIUrl":null,"url":null,"abstract":"This study aims to obtain a better contrast in the film image on X-ray examination of the ossa manus in posteroanterior projection with the addition of an acrylic compensating filter. An investigation was carried out using the phantom manus object on the Quantum CS-2 X-ray apparatus in the examination room 1 of the Margono Soekarjo Hospital (RSMS) by adding acrylic material on the outside of the collimator with a thickness ranging from 2 mm to 22 mm as a determinant of the thickness of the compensation filter. The radiographs were processed by a CR reader and imported into the Weasis software version 2.0.7 to analyze their pixel values. The results showed different compensatory filter thicknesses in the carpal and distal phalanges. An acrylic compensation filter with a thickness of 2.32 cm was considered optimal to compensate for the distal phalanges area and 0.08 cm for the carpal area in the phantom manus with an exposure factor of 55 kV and five mAs.","PeriodicalId":7271,"journal":{"name":"Advanced Materials Research","volume":"298 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Acrylic Compensation Filter Design Enhances the X-Ray Image of the Ossa Manus in Posteroanterior Projection\",\"authors\":\"Mukhtar Effendi, Sri Maryanah, Agus Sholeh, Wiwiek Fatchurohmah\",\"doi\":\"10.4028/p-99gfws\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study aims to obtain a better contrast in the film image on X-ray examination of the ossa manus in posteroanterior projection with the addition of an acrylic compensating filter. An investigation was carried out using the phantom manus object on the Quantum CS-2 X-ray apparatus in the examination room 1 of the Margono Soekarjo Hospital (RSMS) by adding acrylic material on the outside of the collimator with a thickness ranging from 2 mm to 22 mm as a determinant of the thickness of the compensation filter. The radiographs were processed by a CR reader and imported into the Weasis software version 2.0.7 to analyze their pixel values. The results showed different compensatory filter thicknesses in the carpal and distal phalanges. An acrylic compensation filter with a thickness of 2.32 cm was considered optimal to compensate for the distal phalanges area and 0.08 cm for the carpal area in the phantom manus with an exposure factor of 55 kV and five mAs.\",\"PeriodicalId\":7271,\"journal\":{\"name\":\"Advanced Materials Research\",\"volume\":\"298 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advanced Materials Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4028/p-99gfws\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Materials Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4028/p-99gfws","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在通过添加丙烯酸补偿滤光片,使肛门后位投影的 X 射线检查胶片图像获得更好的对比度。研究人员在 Margono Soekarjo 医院(RSMS)1 号检查室的 Quantum CS-2 X 射线仪器上使用肛门模型进行了研究,方法是在准直器外侧添加丙烯酸材料,厚度从 2 毫米到 22 毫米不等,作为补偿滤光片厚度的决定因素。射线照片由 CR 读取器处理,并导入 Weasis 软件 2.0.7 版分析其像素值。结果显示,腕骨和远节指骨的补偿滤光片厚度不同。在 55 kV 和 5 mAs 的曝光系数下,厚度为 2.32 cm 的丙烯酸补偿滤光片被认为是对远端指骨区域和 0.08 cm 的腕骨区域进行补偿的最佳选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Acrylic Compensation Filter Design Enhances the X-Ray Image of the Ossa Manus in Posteroanterior Projection
This study aims to obtain a better contrast in the film image on X-ray examination of the ossa manus in posteroanterior projection with the addition of an acrylic compensating filter. An investigation was carried out using the phantom manus object on the Quantum CS-2 X-ray apparatus in the examination room 1 of the Margono Soekarjo Hospital (RSMS) by adding acrylic material on the outside of the collimator with a thickness ranging from 2 mm to 22 mm as a determinant of the thickness of the compensation filter. The radiographs were processed by a CR reader and imported into the Weasis software version 2.0.7 to analyze their pixel values. The results showed different compensatory filter thicknesses in the carpal and distal phalanges. An acrylic compensation filter with a thickness of 2.32 cm was considered optimal to compensate for the distal phalanges area and 0.08 cm for the carpal area in the phantom manus with an exposure factor of 55 kV and five mAs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信