{"title":"mAs 变化对骨股骨 X 射线片密度的影响","authors":"Cipta Ismaya Rahman, A. Annisa, M. Firdaus","doi":"10.31983/jimed.v10i1.10434","DOIUrl":null,"url":null,"abstract":"Background: The human body's anatomical structure may be seen in radiological image findings. The proper exposure factor must be given in order to produce radiographic findings. The amperage value times the exposure period is equal to mAs. A darker image will result from a larger mA factor or longer exposure time. However, by choosing the appropriate exposure factor, an optimal radiograph density can be produced that can clearly display the difference in thickness and density between organs. The purpose of this study is to determine the results of how density affects the results of radiographs of the os femur.Methods: This research is quantitative using experimental methods to find out how the effect of mAs variations and how much the range of changes in value on density in AP projection femur examinations using mAs variations namely mAs 4, 8, 10, 12, 20, 25, and 32 with a fixed kV of 70 kV.Results: The results of this study indicate that there is a change in the effect of density quality on the variation of mAs on the radiograph results of the femoral os using the Friedman test p-value 0.001 which means less than 0.05. And the range of changes in density values at the caput femur, collum femur, collum femur, and greater trochanter there are changes in each mAs variation. The value of density variation against 7 mAs variations in radiograph results at variations of 4 to 32 mAs shows the density value increases by 0.14, for the range of increase in each variation it is ± from 0.02 to 0.05.Conclusions: The purpose of this study is to determine the results of how density is affected and the results of how the range of changes in density values on femur radiographs.","PeriodicalId":205622,"journal":{"name":"Jurnal Imejing Diagnostik (JImeD)","volume":"210 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Pengaruh Variasi mAs terhadap Densitas pada Hasil Radiograf Os Femur\",\"authors\":\"Cipta Ismaya Rahman, A. Annisa, M. Firdaus\",\"doi\":\"10.31983/jimed.v10i1.10434\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: The human body's anatomical structure may be seen in radiological image findings. The proper exposure factor must be given in order to produce radiographic findings. The amperage value times the exposure period is equal to mAs. A darker image will result from a larger mA factor or longer exposure time. However, by choosing the appropriate exposure factor, an optimal radiograph density can be produced that can clearly display the difference in thickness and density between organs. The purpose of this study is to determine the results of how density affects the results of radiographs of the os femur.Methods: This research is quantitative using experimental methods to find out how the effect of mAs variations and how much the range of changes in value on density in AP projection femur examinations using mAs variations namely mAs 4, 8, 10, 12, 20, 25, and 32 with a fixed kV of 70 kV.Results: The results of this study indicate that there is a change in the effect of density quality on the variation of mAs on the radiograph results of the femoral os using the Friedman test p-value 0.001 which means less than 0.05. And the range of changes in density values at the caput femur, collum femur, collum femur, and greater trochanter there are changes in each mAs variation. The value of density variation against 7 mAs variations in radiograph results at variations of 4 to 32 mAs shows the density value increases by 0.14, for the range of increase in each variation it is ± from 0.02 to 0.05.Conclusions: The purpose of this study is to determine the results of how density is affected and the results of how the range of changes in density values on femur radiographs.\",\"PeriodicalId\":205622,\"journal\":{\"name\":\"Jurnal Imejing Diagnostik (JImeD)\",\"volume\":\"210 \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Imejing Diagnostik (JImeD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31983/jimed.v10i1.10434\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Imejing Diagnostik (JImeD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31983/jimed.v10i1.10434","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
背景:人体的解剖结构可在放射影像结果中看到。必须给出适当的曝光系数才能产生放射影像结果。安培值乘以曝光时间等于 mAs。毫安系数越大或曝光时间越长,图像越暗。不过,通过选择适当的曝光系数,可以产生最佳的射线密度,从而清晰显示器官之间的厚度和密度差异。本研究的目的是确定密度对股骨颈射线照相结果的影响:本研究采用实验方法定量分析 mAs 变化对股骨 AP 投影密度的影响,以及在固定电压为 70 kV 的情况下,mAs 4、8、10、12、20、25 和 32 的变化值对密度的影响范围:研究结果表明,通过弗里德曼检验,密度质量对 mAs 的变化对股骨颈X光片结果的影响存在变化,P 值为 0.001,即小于 0.05。而股骨盖、股骨粗隆、股骨粗隆和股骨大转子处密度值的变化范围在每个 mAs 变化中都有变化。在 4 至 32 mAs 的变化中,X 光片结果中 7 mAs 的密度变化值显示密度值增加了 0.14,每个变化的增加范围为 ± 0.02 至 0.05:本研究的目的是确定密度如何受到影响以及股骨X光片密度值变化范围的结果。
Pengaruh Variasi mAs terhadap Densitas pada Hasil Radiograf Os Femur
Background: The human body's anatomical structure may be seen in radiological image findings. The proper exposure factor must be given in order to produce radiographic findings. The amperage value times the exposure period is equal to mAs. A darker image will result from a larger mA factor or longer exposure time. However, by choosing the appropriate exposure factor, an optimal radiograph density can be produced that can clearly display the difference in thickness and density between organs. The purpose of this study is to determine the results of how density affects the results of radiographs of the os femur.Methods: This research is quantitative using experimental methods to find out how the effect of mAs variations and how much the range of changes in value on density in AP projection femur examinations using mAs variations namely mAs 4, 8, 10, 12, 20, 25, and 32 with a fixed kV of 70 kV.Results: The results of this study indicate that there is a change in the effect of density quality on the variation of mAs on the radiograph results of the femoral os using the Friedman test p-value 0.001 which means less than 0.05. And the range of changes in density values at the caput femur, collum femur, collum femur, and greater trochanter there are changes in each mAs variation. The value of density variation against 7 mAs variations in radiograph results at variations of 4 to 32 mAs shows the density value increases by 0.14, for the range of increase in each variation it is ± from 0.02 to 0.05.Conclusions: The purpose of this study is to determine the results of how density is affected and the results of how the range of changes in density values on femur radiographs.