{"title":"改善通风木屋顶防潮安全方法的数值研究","authors":"Klaus Viljanen, Laurina Felius","doi":"10.5755/j01.sace.34.1.35512","DOIUrl":null,"url":null,"abstract":"The hygrothermal performance of highly insulated, prefabricated wooden roof structures is likely to deteriorate due to the low heat flux to the ventilation cavity. This article evaluates the possibility to improve the moisture safety of such roofs in a Nordic climate by using different control methods for the ventilation rate of the roof and by using thermal insulation above the roof sheathing. The results support the use of adaptive roof ventilation as it decreases the probability of mould growth in the roof. The use of thermal insulation above roof sheathing decreases the probability of mould growth only slightly in a roof with elevated amount of built-in moisture.","PeriodicalId":36795,"journal":{"name":"Journal of Sustainable Architecture and Civil Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-02-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Numerical Study of Methods to Improve Moisture Safety of Ventilated Wooden Roofs\",\"authors\":\"Klaus Viljanen, Laurina Felius\",\"doi\":\"10.5755/j01.sace.34.1.35512\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The hygrothermal performance of highly insulated, prefabricated wooden roof structures is likely to deteriorate due to the low heat flux to the ventilation cavity. This article evaluates the possibility to improve the moisture safety of such roofs in a Nordic climate by using different control methods for the ventilation rate of the roof and by using thermal insulation above the roof sheathing. The results support the use of adaptive roof ventilation as it decreases the probability of mould growth in the roof. The use of thermal insulation above roof sheathing decreases the probability of mould growth only slightly in a roof with elevated amount of built-in moisture.\",\"PeriodicalId\":36795,\"journal\":{\"name\":\"Journal of Sustainable Architecture and Civil Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Sustainable Architecture and Civil Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5755/j01.sace.34.1.35512\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Sustainable Architecture and Civil Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5755/j01.sace.34.1.35512","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

摘要

由于进入通风腔的热通量较低,高度隔热的预制木质屋顶结构的湿热性能可能会下降。本文评估了在北欧气候条件下,通过采用不同的屋顶通风率控制方法和在屋顶覆面板上方使用隔热材料来提高此类屋顶防潮安全性的可能性。研究结果支持使用自适应屋顶通风,因为它可以降低屋顶霉菌生长的概率。在屋顶覆面板上使用隔热材料只能略微降低内置湿度较高的屋顶中霉菌生长的几率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Numerical Study of Methods to Improve Moisture Safety of Ventilated Wooden Roofs
The hygrothermal performance of highly insulated, prefabricated wooden roof structures is likely to deteriorate due to the low heat flux to the ventilation cavity. This article evaluates the possibility to improve the moisture safety of such roofs in a Nordic climate by using different control methods for the ventilation rate of the roof and by using thermal insulation above the roof sheathing. The results support the use of adaptive roof ventilation as it decreases the probability of mould growth in the roof. The use of thermal insulation above roof sheathing decreases the probability of mould growth only slightly in a roof with elevated amount of built-in moisture.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.20
自引率
0.00%
发文量
21
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信