用于多功能柔性应变计的可拉伸强韧导电弹性薄膜

Qirui Wu, Anbang Chen, Yujia Chen, Jiayu Zhang, Songjiu Han, Jianren Huang, Xiaoxiang Yang, Lunhui Guan
{"title":"用于多功能柔性应变计的可拉伸强韧导电弹性薄膜","authors":"Qirui Wu,&nbsp;Anbang Chen,&nbsp;Yujia Chen,&nbsp;Jiayu Zhang,&nbsp;Songjiu Han,&nbsp;Jianren Huang,&nbsp;Xiaoxiang Yang,&nbsp;Lunhui Guan","doi":"10.1002/adsr.202300208","DOIUrl":null,"url":null,"abstract":"<p>As an important branch of modern science and technology, flexible sensor combines the functions of traditional sensors with the characteristics of flexible materials to meet the needs of modern electronic devices for lightweight, flexible and wearable characteristics. However, flexible sensors are faced with problems such as poor stability and weak anti-interference ability in extreme environments. Here, a strategy of combining thermoplastic polyurethane and conductive carbon black is adopted to obtain conductive elastic film with good conductivity and excellent mechanical properties (TPU@CB film). TPU@CB film exhibits very good mechanical strength (8 MPa). When TPU@CB film is assembled into a sensor, it exhibits wide detection range (600%), low detection limit (0.05%) and short response time (15 ms). Notably, the TPU@CB film demonstrates clear detection capabilities for both ECG and EMG signals of the human body when utilized as an electrode patch. Thanks to lithography, TPU@CB film is machined into strain gauge shape. TPU@CB strain gauge achieves a high signal-to-noise ratio and can detect a wide range of frequency vibrations from 0 to 900 Hz, as well as accurately detect the speed of the motor. This provides a feasible way to promote the development of flexible electronics.</p>","PeriodicalId":100037,"journal":{"name":"Advanced Sensor Research","volume":"3 6","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/adsr.202300208","citationCount":"0","resultStr":"{\"title\":\"A Stretchable and Tough Conductive Elastic Film for Multifunctional Flexible Strain Gauges\",\"authors\":\"Qirui Wu,&nbsp;Anbang Chen,&nbsp;Yujia Chen,&nbsp;Jiayu Zhang,&nbsp;Songjiu Han,&nbsp;Jianren Huang,&nbsp;Xiaoxiang Yang,&nbsp;Lunhui Guan\",\"doi\":\"10.1002/adsr.202300208\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>As an important branch of modern science and technology, flexible sensor combines the functions of traditional sensors with the characteristics of flexible materials to meet the needs of modern electronic devices for lightweight, flexible and wearable characteristics. However, flexible sensors are faced with problems such as poor stability and weak anti-interference ability in extreme environments. Here, a strategy of combining thermoplastic polyurethane and conductive carbon black is adopted to obtain conductive elastic film with good conductivity and excellent mechanical properties (TPU@CB film). TPU@CB film exhibits very good mechanical strength (8 MPa). When TPU@CB film is assembled into a sensor, it exhibits wide detection range (600%), low detection limit (0.05%) and short response time (15 ms). Notably, the TPU@CB film demonstrates clear detection capabilities for both ECG and EMG signals of the human body when utilized as an electrode patch. Thanks to lithography, TPU@CB film is machined into strain gauge shape. TPU@CB strain gauge achieves a high signal-to-noise ratio and can detect a wide range of frequency vibrations from 0 to 900 Hz, as well as accurately detect the speed of the motor. This provides a feasible way to promote the development of flexible electronics.</p>\",\"PeriodicalId\":100037,\"journal\":{\"name\":\"Advanced Sensor Research\",\"volume\":\"3 6\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/adsr.202300208\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advanced Sensor Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/adsr.202300208\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Sensor Research","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/adsr.202300208","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

作为现代科学技术的一个重要分支,柔性传感器将传统传感器的功能与柔性材料的特性相结合,以满足现代电子设备对轻便、柔性和可穿戴特性的需求。然而,柔性传感器面临着在极端环境下稳定性差、抗干扰能力弱等问题。在此,我们采用热塑性聚氨酯与导电碳黑相结合的策略,获得了具有良好导电性和优异机械性能的导电弹性薄膜(TPU@CB 薄膜)。TPU@CB 薄膜具有非常好的机械强度(8 兆帕)。将 TPU@CB 薄膜组装成传感器后,可实现宽检测范围(600%)、低检测限(0.05%)和短响应时间(15 毫秒)。值得注意的是,当 TPU@CB 薄膜用作电极贴片时,它对人体的心电图和肌电图信号都具有明显的检测能力。通过光刻技术,TPU@CB 薄膜被加工成应变片形状。TPU@CB 应变片实现了高信噪比,可检测 0 至 900 Hz 的各种频率振动,并能准确检测电机的速度。这为推动柔性电子技术的发展提供了可行的途径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

A Stretchable and Tough Conductive Elastic Film for Multifunctional Flexible Strain Gauges

A Stretchable and Tough Conductive Elastic Film for Multifunctional Flexible Strain Gauges

As an important branch of modern science and technology, flexible sensor combines the functions of traditional sensors with the characteristics of flexible materials to meet the needs of modern electronic devices for lightweight, flexible and wearable characteristics. However, flexible sensors are faced with problems such as poor stability and weak anti-interference ability in extreme environments. Here, a strategy of combining thermoplastic polyurethane and conductive carbon black is adopted to obtain conductive elastic film with good conductivity and excellent mechanical properties (TPU@CB film). TPU@CB film exhibits very good mechanical strength (8 MPa). When TPU@CB film is assembled into a sensor, it exhibits wide detection range (600%), low detection limit (0.05%) and short response time (15 ms). Notably, the TPU@CB film demonstrates clear detection capabilities for both ECG and EMG signals of the human body when utilized as an electrode patch. Thanks to lithography, TPU@CB film is machined into strain gauge shape. TPU@CB strain gauge achieves a high signal-to-noise ratio and can detect a wide range of frequency vibrations from 0 to 900 Hz, as well as accurately detect the speed of the motor. This provides a feasible way to promote the development of flexible electronics.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信