{"title":"放疗计划目标体积的确定 - 综述","authors":"Dhanjit Lahkar","doi":"10.18535/jmscr/v12i02.03","DOIUrl":null,"url":null,"abstract":"Treatment volume definitions used in three-dimensional radiotherapy treatment planning are essential in advancing treatment modalities. However, there are many sources of error during the treatment preparation and execution that limit the accuracy. Consequently, a safety margin is required to add to the target to ensure that the planned dose is delivered to the target. Multiple margins surround the tumour to reduce positional inaccuracy, such as Clinical Target Volume (CTV), Planning Target Volume (PTV), etc. The International Commission of Units and Measurement (ICRU) recommended margins in 1978. It was later reviewed in Reports 50 and 62 of ICRU, providing information on margins covering gross volume, clinical volume, and critical structures that should be eliminated as feasible. This article aims to discuss various techniques and methods that various authors have created. Keywords: Margin, Errors, GTV, CTV, ITV, PTV, ICRU 50, ICRU 62, Radiotherapy.","PeriodicalId":16362,"journal":{"name":"Journal of Medical Science And clinical Research","volume":"571 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of Planning Target Volume in Radiotherapy - A Review\",\"authors\":\"Dhanjit Lahkar\",\"doi\":\"10.18535/jmscr/v12i02.03\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Treatment volume definitions used in three-dimensional radiotherapy treatment planning are essential in advancing treatment modalities. However, there are many sources of error during the treatment preparation and execution that limit the accuracy. Consequently, a safety margin is required to add to the target to ensure that the planned dose is delivered to the target. Multiple margins surround the tumour to reduce positional inaccuracy, such as Clinical Target Volume (CTV), Planning Target Volume (PTV), etc. The International Commission of Units and Measurement (ICRU) recommended margins in 1978. It was later reviewed in Reports 50 and 62 of ICRU, providing information on margins covering gross volume, clinical volume, and critical structures that should be eliminated as feasible. This article aims to discuss various techniques and methods that various authors have created. Keywords: Margin, Errors, GTV, CTV, ITV, PTV, ICRU 50, ICRU 62, Radiotherapy.\",\"PeriodicalId\":16362,\"journal\":{\"name\":\"Journal of Medical Science And clinical Research\",\"volume\":\"571 3\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Science And clinical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18535/jmscr/v12i02.03\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Science And clinical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18535/jmscr/v12i02.03","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

三维放疗治疗计划中使用的治疗容积定义对治疗模式的发展至关重要。然而,在治疗准备和执行过程中,有许多误差源会限制治疗的准确性。因此,需要在靶点上增加一个安全裕度,以确保将计划剂量传递到靶点。肿瘤周围有多个余量,以减少定位的不准确性,如临床靶体积(CTV)、计划靶体积(PTV)等。国际单位与测量委员会(ICRU)于 1978 年推荐了边缘。后来,ICRU 在第 50 和 62 号报告中对其进行了复审,提供了涵盖总容积、临床容积和应尽可能消除的关键结构的边缘信息。本文旨在讨论不同作者创造的各种技术和方法。关键词边缘、误差、GTV、CTV、ITV、PTV、ICRU 50、ICRU 62、放射治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Determination of Planning Target Volume in Radiotherapy - A Review
Treatment volume definitions used in three-dimensional radiotherapy treatment planning are essential in advancing treatment modalities. However, there are many sources of error during the treatment preparation and execution that limit the accuracy. Consequently, a safety margin is required to add to the target to ensure that the planned dose is delivered to the target. Multiple margins surround the tumour to reduce positional inaccuracy, such as Clinical Target Volume (CTV), Planning Target Volume (PTV), etc. The International Commission of Units and Measurement (ICRU) recommended margins in 1978. It was later reviewed in Reports 50 and 62 of ICRU, providing information on margins covering gross volume, clinical volume, and critical structures that should be eliminated as feasible. This article aims to discuss various techniques and methods that various authors have created. Keywords: Margin, Errors, GTV, CTV, ITV, PTV, ICRU 50, ICRU 62, Radiotherapy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信