利用模拟模型识别垂直分布异常点的电阻率法的实用性

Q3 Earth and Planetary Sciences
Raad Eissa
{"title":"利用模拟模型识别垂直分布异常点的电阻率法的实用性","authors":"Raad Eissa","doi":"10.46717/igj.57.1b.16ms-2024-2-25","DOIUrl":null,"url":null,"abstract":"In brownfield sites, two proposed shallow horizontal targets were numerically modelled to mimic variable underground conditions; these targets were sequenced vertically in a different manner. Synthetic 2D electrical resistivity datasets were generated using the RES2DMOD and then inverted by using RES2DINVx64. These targets have different lengths, one with a higher and the second with a lower resistivity value relative to the background resistivity. The effectiveness of dipole-dipole, Wenner, and Wenner-Schlumberger configurations was tested by conducting a qualitative comparison. The inverted resistivity images suggest that the target sequence has a significant effect on the configuration detectability. The high resistivity target was conveniently recognized when it overlies a low resistivity target. Dipole-dipole configuration showed optimum results in recognizing complicated underground conditions.","PeriodicalId":14847,"journal":{"name":"Iraqi Geological Journal","volume":"64 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Practicality of Resistivity Method for Recognizing Vertically Distributed Anomalies Using Simulated Models\",\"authors\":\"Raad Eissa\",\"doi\":\"10.46717/igj.57.1b.16ms-2024-2-25\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In brownfield sites, two proposed shallow horizontal targets were numerically modelled to mimic variable underground conditions; these targets were sequenced vertically in a different manner. Synthetic 2D electrical resistivity datasets were generated using the RES2DMOD and then inverted by using RES2DINVx64. These targets have different lengths, one with a higher and the second with a lower resistivity value relative to the background resistivity. The effectiveness of dipole-dipole, Wenner, and Wenner-Schlumberger configurations was tested by conducting a qualitative comparison. The inverted resistivity images suggest that the target sequence has a significant effect on the configuration detectability. The high resistivity target was conveniently recognized when it overlies a low resistivity target. Dipole-dipole configuration showed optimum results in recognizing complicated underground conditions.\",\"PeriodicalId\":14847,\"journal\":{\"name\":\"Iraqi Geological Journal\",\"volume\":\"64 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iraqi Geological Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.46717/igj.57.1b.16ms-2024-2-25\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Earth and Planetary Sciences\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iraqi Geological Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46717/igj.57.1b.16ms-2024-2-25","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Earth and Planetary Sciences","Score":null,"Total":0}
引用次数: 0

摘要

在棕地,对两个拟议的浅层水平目标进行了数值建模,以模拟多变的地下条件;这些目标以不同的方式进行了垂直排序。使用 RES2DMOD 生成合成二维电阻率数据集,然后使用 RES2DINVx64 进行反演。这些目标具有不同的长度,相对于背景电阻率,一个目标的电阻率值较高,另一个目标的电阻率值较低。通过定性比较,测试了偶极-偶极、温纳和温纳-施伦贝谢配置的有效性。反转电阻率图像表明,目标序列对配置的可探测性有显著影响。当高电阻率目标覆盖在低电阻率目标上时,就很容易识别。偶极-偶极配置在识别复杂地下条件时显示出最佳效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Practicality of Resistivity Method for Recognizing Vertically Distributed Anomalies Using Simulated Models
In brownfield sites, two proposed shallow horizontal targets were numerically modelled to mimic variable underground conditions; these targets were sequenced vertically in a different manner. Synthetic 2D electrical resistivity datasets were generated using the RES2DMOD and then inverted by using RES2DINVx64. These targets have different lengths, one with a higher and the second with a lower resistivity value relative to the background resistivity. The effectiveness of dipole-dipole, Wenner, and Wenner-Schlumberger configurations was tested by conducting a qualitative comparison. The inverted resistivity images suggest that the target sequence has a significant effect on the configuration detectability. The high resistivity target was conveniently recognized when it overlies a low resistivity target. Dipole-dipole configuration showed optimum results in recognizing complicated underground conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Iraqi Geological Journal
Iraqi Geological Journal Earth and Planetary Sciences-Geology
CiteScore
1.80
自引率
0.00%
发文量
152
审稿时长
7 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信