为儿科中心静脉置管开发解剖精确的三维模拟模型

Ashley Carver, Ashley Bjorklund, J. Broomhead, E. Graba, Sadhika Prabhu, Gwen Fischer
{"title":"为儿科中心静脉置管开发解剖精确的三维模拟模型","authors":"Ashley Carver, Ashley Bjorklund, J. Broomhead, E. Graba, Sadhika Prabhu, Gwen Fischer","doi":"10.1115/1.4065172","DOIUrl":null,"url":null,"abstract":"\n Background: ICU patients can require a central venous catheter (CVC) which medical trainees often place.\n Objective: The purpose of this study was to create a novel 3-dimensional (3D) printed model, based on actual patient anatomy from a deidentified computed tomography (CT) scan, with improved anatomy, tactile properties and realism beyond current task trainers for pediatric CVC simulation.\n Design/Methods: Bakken researchers converted CT DICOM slices into a 3D model using multiple computer programs and multiple 3D printers. Faculty of various subspecialties at our institution attempted to place a CVC line into the model and then evaluated the model in 5 categories using an anonymous REDCap survey.\n Results: 15 faculty participated and 14 completed their survey. Feedback, based on a 0-10 scale with 10 being highest, was as follows: the model's size scored an average of 8.4, the model's tactile properties scored a 6.1, the model's anatomy received a 7.1, the model's perceived usefulness for practicing central lines received a 7.6, and the model received a 7.6 in regard to whether it should be utilized in procedural training curriculums. Additional comments were collected in the survey and participants requested the model's blood vessels be fully visible on ultrasound and that the model be firmer.\n Conclusion(s): Creating a 3D simulation model for pediatric CVC placement is possible. Next steps for this project include revision of the model to be firmer and with improved vessel appearance on ultrasound.","PeriodicalId":506673,"journal":{"name":"Journal of Medical Devices","volume":"104 25","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of an Anatomically Accurate 3D Simulation Model for Pediatric Central Line Placement\",\"authors\":\"Ashley Carver, Ashley Bjorklund, J. Broomhead, E. Graba, Sadhika Prabhu, Gwen Fischer\",\"doi\":\"10.1115/1.4065172\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Background: ICU patients can require a central venous catheter (CVC) which medical trainees often place.\\n Objective: The purpose of this study was to create a novel 3-dimensional (3D) printed model, based on actual patient anatomy from a deidentified computed tomography (CT) scan, with improved anatomy, tactile properties and realism beyond current task trainers for pediatric CVC simulation.\\n Design/Methods: Bakken researchers converted CT DICOM slices into a 3D model using multiple computer programs and multiple 3D printers. Faculty of various subspecialties at our institution attempted to place a CVC line into the model and then evaluated the model in 5 categories using an anonymous REDCap survey.\\n Results: 15 faculty participated and 14 completed their survey. Feedback, based on a 0-10 scale with 10 being highest, was as follows: the model's size scored an average of 8.4, the model's tactile properties scored a 6.1, the model's anatomy received a 7.1, the model's perceived usefulness for practicing central lines received a 7.6, and the model received a 7.6 in regard to whether it should be utilized in procedural training curriculums. Additional comments were collected in the survey and participants requested the model's blood vessels be fully visible on ultrasound and that the model be firmer.\\n Conclusion(s): Creating a 3D simulation model for pediatric CVC placement is possible. Next steps for this project include revision of the model to be firmer and with improved vessel appearance on ultrasound.\",\"PeriodicalId\":506673,\"journal\":{\"name\":\"Journal of Medical Devices\",\"volume\":\"104 25\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Devices\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4065172\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/1.4065172","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:重症监护室的患者可能需要中心静脉导管(CVC),而医学实习生通常会为患者置管。研究目的本研究的目的是根据去识别计算机断层扫描(CT)中的实际患者解剖结构,创建一种新型三维(3D)打印模型,该模型在解剖结构、触觉特性和逼真度方面均有所改进,超越了目前用于儿科 CVC 模拟的任务训练器。设计/方法:巴肯研究人员使用多个计算机程序和多台三维打印机将 CT DICOM 切片转换成三维模型。本院各亚专科的教师尝试将 CVC 管路放入模型中,然后通过匿名 REDCap 调查对模型进行 5 个类别的评估。结果:15 名教师参与了调查,其中 14 人完成了调查。根据 0-10 分(10 分最高)的评分标准,反馈如下:模型的大小平均得分为 8.4 分,模型的触觉特性得分为 6.1 分,模型的解剖学得分为 7.1 分,模型在练习中心静脉置管方面的实用性得分为 7.6 分,模型是否应在程序培训课程中使用得分为 7.6 分。调查还收集了其他意见,参与者要求模型的血管在超声波下完全可见,模型应更坚固。结论为儿科 CVC 置管创建三维模拟模型是可行的。该项目的下一步工作包括修改模型,使其更加坚固,并改善血管在超声波上的显示效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of an Anatomically Accurate 3D Simulation Model for Pediatric Central Line Placement
Background: ICU patients can require a central venous catheter (CVC) which medical trainees often place. Objective: The purpose of this study was to create a novel 3-dimensional (3D) printed model, based on actual patient anatomy from a deidentified computed tomography (CT) scan, with improved anatomy, tactile properties and realism beyond current task trainers for pediatric CVC simulation. Design/Methods: Bakken researchers converted CT DICOM slices into a 3D model using multiple computer programs and multiple 3D printers. Faculty of various subspecialties at our institution attempted to place a CVC line into the model and then evaluated the model in 5 categories using an anonymous REDCap survey. Results: 15 faculty participated and 14 completed their survey. Feedback, based on a 0-10 scale with 10 being highest, was as follows: the model's size scored an average of 8.4, the model's tactile properties scored a 6.1, the model's anatomy received a 7.1, the model's perceived usefulness for practicing central lines received a 7.6, and the model received a 7.6 in regard to whether it should be utilized in procedural training curriculums. Additional comments were collected in the survey and participants requested the model's blood vessels be fully visible on ultrasound and that the model be firmer. Conclusion(s): Creating a 3D simulation model for pediatric CVC placement is possible. Next steps for this project include revision of the model to be firmer and with improved vessel appearance on ultrasound.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信