通过现场 CT 分数血流储备评估接受经导管主动脉瓣置换术患者的冠状动脉疾病。

IF 3.8 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Alexandra Steyer, Valentina O Puntmann, Eike Nagel, David M Leistner, Vitali Koch, Mariuca Vasa-Nicotera, Parveen Kumar, Christian Booz, Thomas J Vogl, Silvia Mas-Peiro, Simon S Martin
{"title":"通过现场 CT 分数血流储备评估接受经导管主动脉瓣置换术患者的冠状动脉疾病。","authors":"Alexandra Steyer, Valentina O Puntmann, Eike Nagel, David M Leistner, Vitali Koch, Mariuca Vasa-Nicotera, Parveen Kumar, Christian Booz, Thomas J Vogl, Silvia Mas-Peiro, Simon S Martin","doi":"10.1148/ryct.230096","DOIUrl":null,"url":null,"abstract":"<p><p>Purpose To examine the clinical feasibility of workstation-based CT fractional flow reserve (CT-FFR) for coronary artery disease (CAD) evaluation during preprocedural planning in patients undergoing transcatheter aortic valve replacement (TAVR). Materials and Methods In this retrospective single-center study, 434 patients scheduled for TAVR between 2018 and 2020 were screened for study inclusion; a relevant proportion of patients (35.0% [152 of 434]) was not suitable for evaluation due to insufficient imaging properties. A total of 112 patients (mean age, 82.1 years ± 6.7 [SD]; 58 [52%] men) were included in the study. Invasive angiography findings, coronary CT angiography results, and Agatston score were acquired and compared with on-site CT-FFR computation for evaluation of CAD and prediction of major adverse cardiovascular events (MACE) within a 24-month follow-up. Results Hemodynamic relevant CAD, as suggested by CT-FFR of 0.80 or less, was found in 41 of 70 (59%) patients with stenosis of 50% or more. MACE occurred in 23 of 112 (20.5%) patients, from which 14 of 23 had stenoses with CT-FFR of 0.80 or less (hazard ratio [HR], 3.33; 95% CI: 1.56, 7.10; <i>P</i> = .002). CT-FFR remained a significant predictor of MACE after inclusion in a multivariable model with relevant covariables (HR, 2.89; 95% CI: 1.22, 6.86; <i>P</i> = .02). An Agatston score of 1000 Agatston units or more (HR, 2.25; 95% CI: 0.98, 5.21; <i>P</i> = .06) and stenoses of 50% or more determined via invasive angiography (HR, 0.94; 95% CI: 0.41, 2.17; <i>P</i> = .88) were not significant predictors of MACE. Conclusion Compared with conventional CAD markers, CT-FFR better predicted adverse outcomes after TAVR. A relevant portion of the screened cohort, however, was not suitable for CT-based CAD evaluation. <b>Keywords:</b> CT, Transcatheter Aortic Valve Implantation/Replacement (TAVI/TAVR), Cardiac, Coronary Arteries, Outcomes Analysis © RSNA, 2024 See also the commentary by Weir-McCall and Pugliese in this issue.</p>","PeriodicalId":21168,"journal":{"name":"Radiology. Cardiothoracic imaging","volume":"6 2","pages":"e230096"},"PeriodicalIF":3.8000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11056750/pdf/","citationCount":"0","resultStr":"{\"title\":\"Coronary Artery Disease Assessment via On-Site CT Fractional Flow Reserve in Patients Undergoing Transcatheter Aortic Valve Replacement.\",\"authors\":\"Alexandra Steyer, Valentina O Puntmann, Eike Nagel, David M Leistner, Vitali Koch, Mariuca Vasa-Nicotera, Parveen Kumar, Christian Booz, Thomas J Vogl, Silvia Mas-Peiro, Simon S Martin\",\"doi\":\"10.1148/ryct.230096\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Purpose To examine the clinical feasibility of workstation-based CT fractional flow reserve (CT-FFR) for coronary artery disease (CAD) evaluation during preprocedural planning in patients undergoing transcatheter aortic valve replacement (TAVR). Materials and Methods In this retrospective single-center study, 434 patients scheduled for TAVR between 2018 and 2020 were screened for study inclusion; a relevant proportion of patients (35.0% [152 of 434]) was not suitable for evaluation due to insufficient imaging properties. A total of 112 patients (mean age, 82.1 years ± 6.7 [SD]; 58 [52%] men) were included in the study. Invasive angiography findings, coronary CT angiography results, and Agatston score were acquired and compared with on-site CT-FFR computation for evaluation of CAD and prediction of major adverse cardiovascular events (MACE) within a 24-month follow-up. Results Hemodynamic relevant CAD, as suggested by CT-FFR of 0.80 or less, was found in 41 of 70 (59%) patients with stenosis of 50% or more. MACE occurred in 23 of 112 (20.5%) patients, from which 14 of 23 had stenoses with CT-FFR of 0.80 or less (hazard ratio [HR], 3.33; 95% CI: 1.56, 7.10; <i>P</i> = .002). CT-FFR remained a significant predictor of MACE after inclusion in a multivariable model with relevant covariables (HR, 2.89; 95% CI: 1.22, 6.86; <i>P</i> = .02). An Agatston score of 1000 Agatston units or more (HR, 2.25; 95% CI: 0.98, 5.21; <i>P</i> = .06) and stenoses of 50% or more determined via invasive angiography (HR, 0.94; 95% CI: 0.41, 2.17; <i>P</i> = .88) were not significant predictors of MACE. Conclusion Compared with conventional CAD markers, CT-FFR better predicted adverse outcomes after TAVR. A relevant portion of the screened cohort, however, was not suitable for CT-based CAD evaluation. <b>Keywords:</b> CT, Transcatheter Aortic Valve Implantation/Replacement (TAVI/TAVR), Cardiac, Coronary Arteries, Outcomes Analysis © RSNA, 2024 See also the commentary by Weir-McCall and Pugliese in this issue.</p>\",\"PeriodicalId\":21168,\"journal\":{\"name\":\"Radiology. Cardiothoracic imaging\",\"volume\":\"6 2\",\"pages\":\"e230096\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11056750/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiology. Cardiothoracic imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1148/ryct.230096\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiology. Cardiothoracic imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1148/ryct.230096","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的 探讨在接受经导管主动脉瓣置换术(TAVR)的患者进行术前规划时,基于工作站的 CT 分数血流储备(CT-FFR)用于冠状动脉疾病(CAD)评估的临床可行性。材料与方法 在这项回顾性单中心研究中,筛选了 2018 年至 2020 年期间计划接受 TAVR 的 434 例患者作为研究对象;由于成像特性不足,有一定比例的患者(35.0% [434 例中的 152 例])不适合接受评估。共有 112 名患者(平均年龄 82.1 岁 ± 6.7 [SD];男性 58 [52%])被纳入研究。研究人员获取了有创血管造影结果、冠状动脉 CT 血管造影结果和 Agatston 评分,并将其与现场 CT-FFR 计算结果进行比较,以评估 CAD 和预测 24 个月随访期间的主要不良心血管事件 (MACE)。结果 在 70 名血管狭窄程度达到或超过 50%的患者中,有 41 人(59%)发现了血流动力学相关的 CAD(CT-FFR 为 0.80 或更低)。112名患者中有23名(20.5%)发生了MACE,其中14名患者的血管狭窄程度为CT-FFR 0.80或以下(危险比[HR],3.33;95% CI:1.56,7.10;P = .002)。在纳入包含相关协变量的多变量模型后,CT-FFR仍是MACE的重要预测因素(HR,2.89;95% CI:1.22,6.86;P = .02)。Agatston评分达到或超过1000 Agatston单位(HR,2.25;95% CI:0.98,5.21;P = .06)以及通过有创血管造影确定的血管狭窄达到或超过50%(HR,0.94;95% CI:0.41,2.17;P = .88)并不能显著预测MACE。结论 与传统的 CAD 标志物相比,CT-FFR 更能预测 TAVR 后的不良预后。然而,在接受筛查的人群中,有相当一部分人不适合进行基于 CT 的 CAD 评估。关键词CT、经导管主动脉瓣植入/置换术(TAVI/TAVR)、心脏、冠状动脉、结果分析 © RSNA, 2024 另请参阅本期 Weir-McCall 和 Pugliese 的评论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Coronary Artery Disease Assessment via On-Site CT Fractional Flow Reserve in Patients Undergoing Transcatheter Aortic Valve Replacement.

Purpose To examine the clinical feasibility of workstation-based CT fractional flow reserve (CT-FFR) for coronary artery disease (CAD) evaluation during preprocedural planning in patients undergoing transcatheter aortic valve replacement (TAVR). Materials and Methods In this retrospective single-center study, 434 patients scheduled for TAVR between 2018 and 2020 were screened for study inclusion; a relevant proportion of patients (35.0% [152 of 434]) was not suitable for evaluation due to insufficient imaging properties. A total of 112 patients (mean age, 82.1 years ± 6.7 [SD]; 58 [52%] men) were included in the study. Invasive angiography findings, coronary CT angiography results, and Agatston score were acquired and compared with on-site CT-FFR computation for evaluation of CAD and prediction of major adverse cardiovascular events (MACE) within a 24-month follow-up. Results Hemodynamic relevant CAD, as suggested by CT-FFR of 0.80 or less, was found in 41 of 70 (59%) patients with stenosis of 50% or more. MACE occurred in 23 of 112 (20.5%) patients, from which 14 of 23 had stenoses with CT-FFR of 0.80 or less (hazard ratio [HR], 3.33; 95% CI: 1.56, 7.10; P = .002). CT-FFR remained a significant predictor of MACE after inclusion in a multivariable model with relevant covariables (HR, 2.89; 95% CI: 1.22, 6.86; P = .02). An Agatston score of 1000 Agatston units or more (HR, 2.25; 95% CI: 0.98, 5.21; P = .06) and stenoses of 50% or more determined via invasive angiography (HR, 0.94; 95% CI: 0.41, 2.17; P = .88) were not significant predictors of MACE. Conclusion Compared with conventional CAD markers, CT-FFR better predicted adverse outcomes after TAVR. A relevant portion of the screened cohort, however, was not suitable for CT-based CAD evaluation. Keywords: CT, Transcatheter Aortic Valve Implantation/Replacement (TAVI/TAVR), Cardiac, Coronary Arteries, Outcomes Analysis © RSNA, 2024 See also the commentary by Weir-McCall and Pugliese in this issue.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
20.40
自引率
1.40%
发文量
0
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信