PulmValve 支气管内瓣膜的首次体内实验:可行性、效率和安全性。

IF 3.5 3区 医学 Q2 RESPIRATORY SYSTEM
Respiration Pub Date : 2024-01-01 Epub Date: 2024-03-26 DOI:10.1159/000538269
Jingwei Liu, Difei Chen, Yanhui Yu, Yu Deng, Ruijin Lu, Jing Zhang, Shiyue Li
{"title":"PulmValve 支气管内瓣膜的首次体内实验:可行性、效率和安全性。","authors":"Jingwei Liu, Difei Chen, Yanhui Yu, Yu Deng, Ruijin Lu, Jing Zhang, Shiyue Li","doi":"10.1159/000538269","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Endoscopic lung volume reduction with endobronchial valves has been widely recognized for treating hyperinflation in advanced chronic obstructive pulmonary disease and emphysema patients. The main challenges include the technical complexity of upper lobe implantation and the number of endobronchial valves required. These issues might be addressed by placing larger diameter valves in the lobar bronchus. This study evaluated the feasibility, efficiency, and safety of the new valve PulmValve (model PV-13) in porcine models.</p><p><strong>Methods: </strong>Six PV-13 valves were bronchoscopically implanted into the caudal lobe bronchus of six healthy pigs. The procedure time, valve deployment, and removability were recorded. Follow-up examinations included blood tests, chest CT scans, and bronchoscopy at 30 min, 14 days, 28 days, and 84 days post-procedure, with necropsy and pathological evaluations after the final follow-up examination.</p><p><strong>Results: </strong>The successful in vivo deployment and removal of PV-13 valves was established, with a median procedure time of 6.5 min. The distal lung volume reduction was evident at 30 min post-operation and was persistently monitored on day 84. No migration or malfunction of any PV-13 valves was detected, but a mild angle deviation was found in 3 cases. Coughing was observed in four pigs within the first 7 days and localized granulation tissue was observed in all pigs. No cases of pneumothorax, diffuse pneumonia, or hemoptysis were detected.</p><p><strong>Conclusions: </strong>In this study, we report the successful implantation and removal of a new valve PulmValve in a short operation time. Complete lobar atelectasis was induced without device migration, malfunction, or severe complications. Further studies are warranted to evaluate the long-term, sustained effects and potential benefits in human patients.</p>","PeriodicalId":21048,"journal":{"name":"Respiration","volume":" ","pages":"344-352"},"PeriodicalIF":3.5000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"First in vivo Experiment with PulmValve Endobronchial Valve: Feasibility, Efficiency, and Safety.\",\"authors\":\"Jingwei Liu, Difei Chen, Yanhui Yu, Yu Deng, Ruijin Lu, Jing Zhang, Shiyue Li\",\"doi\":\"10.1159/000538269\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Endoscopic lung volume reduction with endobronchial valves has been widely recognized for treating hyperinflation in advanced chronic obstructive pulmonary disease and emphysema patients. The main challenges include the technical complexity of upper lobe implantation and the number of endobronchial valves required. These issues might be addressed by placing larger diameter valves in the lobar bronchus. This study evaluated the feasibility, efficiency, and safety of the new valve PulmValve (model PV-13) in porcine models.</p><p><strong>Methods: </strong>Six PV-13 valves were bronchoscopically implanted into the caudal lobe bronchus of six healthy pigs. The procedure time, valve deployment, and removability were recorded. Follow-up examinations included blood tests, chest CT scans, and bronchoscopy at 30 min, 14 days, 28 days, and 84 days post-procedure, with necropsy and pathological evaluations after the final follow-up examination.</p><p><strong>Results: </strong>The successful in vivo deployment and removal of PV-13 valves was established, with a median procedure time of 6.5 min. The distal lung volume reduction was evident at 30 min post-operation and was persistently monitored on day 84. No migration or malfunction of any PV-13 valves was detected, but a mild angle deviation was found in 3 cases. Coughing was observed in four pigs within the first 7 days and localized granulation tissue was observed in all pigs. No cases of pneumothorax, diffuse pneumonia, or hemoptysis were detected.</p><p><strong>Conclusions: </strong>In this study, we report the successful implantation and removal of a new valve PulmValve in a short operation time. Complete lobar atelectasis was induced without device migration, malfunction, or severe complications. Further studies are warranted to evaluate the long-term, sustained effects and potential benefits in human patients.</p>\",\"PeriodicalId\":21048,\"journal\":{\"name\":\"Respiration\",\"volume\":\" \",\"pages\":\"344-352\"},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Respiration\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1159/000538269\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"RESPIRATORY SYSTEM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Respiration","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000538269","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/26 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0

摘要

导言:使用支气管内瓣膜进行内镜肺容积缩小术(ELVR)治疗晚期慢性阻塞性肺疾病和肺气肿患者的过度充气已得到广泛认可。主要挑战包括上叶植入的技术复杂性和所需支气管内瓣膜的数量。这些问题可通过在肺叶支气管中植入更大直径的瓣膜来解决。本研究在猪模型中评估了新型瓣膜 PulmValve(型号 PV-13)的可行性、效率和安全性:方法:通过支气管镜将六个 PV-13 瓣膜植入六头健康猪的尾叶支气管。记录手术时间、瓣膜部署和移除情况。随访检查包括血液化验、胸部 CT 扫描以及术后 30 分钟、14 天、28 天和 84 天的支气管镜检查,并在最后一次随访检查后进行尸检和病理评估:结果:PV-13瓣膜的体内置入和移除均获得成功,中位手术时间为6.5分钟。远端肺容积在术后 30 分钟明显缩小,并持续监测到第 84 天。未发现任何 PV-13 瓣膜移位或故障,但在三个病例中发现了轻微的角度偏差。在最初的七天内,四头猪出现了咳嗽,所有猪的局部都出现了肉芽组织。未发现气胸、弥漫性肺炎或咯血病例:在这项研究中,我们报告了在短时间内成功植入和取出新型瓣膜 PulmValve 的情况。在没有发生装置移位、故障或严重并发症的情况下,诱发了完全性肺叶缺氧。我们有必要开展进一步研究,以评估其对人类患者的长期、持续影响和潜在益处。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
First in vivo Experiment with PulmValve Endobronchial Valve: Feasibility, Efficiency, and Safety.

Introduction: Endoscopic lung volume reduction with endobronchial valves has been widely recognized for treating hyperinflation in advanced chronic obstructive pulmonary disease and emphysema patients. The main challenges include the technical complexity of upper lobe implantation and the number of endobronchial valves required. These issues might be addressed by placing larger diameter valves in the lobar bronchus. This study evaluated the feasibility, efficiency, and safety of the new valve PulmValve (model PV-13) in porcine models.

Methods: Six PV-13 valves were bronchoscopically implanted into the caudal lobe bronchus of six healthy pigs. The procedure time, valve deployment, and removability were recorded. Follow-up examinations included blood tests, chest CT scans, and bronchoscopy at 30 min, 14 days, 28 days, and 84 days post-procedure, with necropsy and pathological evaluations after the final follow-up examination.

Results: The successful in vivo deployment and removal of PV-13 valves was established, with a median procedure time of 6.5 min. The distal lung volume reduction was evident at 30 min post-operation and was persistently monitored on day 84. No migration or malfunction of any PV-13 valves was detected, but a mild angle deviation was found in 3 cases. Coughing was observed in four pigs within the first 7 days and localized granulation tissue was observed in all pigs. No cases of pneumothorax, diffuse pneumonia, or hemoptysis were detected.

Conclusions: In this study, we report the successful implantation and removal of a new valve PulmValve in a short operation time. Complete lobar atelectasis was induced without device migration, malfunction, or severe complications. Further studies are warranted to evaluate the long-term, sustained effects and potential benefits in human patients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Respiration
Respiration 医学-呼吸系统
CiteScore
7.30
自引率
5.40%
发文量
82
审稿时长
4-8 weeks
期刊介绍: ''Respiration'' brings together the results of both clinical and experimental investigations on all aspects of the respiratory system in health and disease. Clinical improvements in the diagnosis and treatment of chest and lung diseases are covered, as are the latest findings in physiology, biochemistry, pathology, immunology and pharmacology. The journal includes classic features such as editorials that accompany original articles in clinical and basic science research, reviews and letters to the editor. Further sections are: Technical Notes, The Eye Catcher, What’s Your Diagnosis?, The Opinion Corner, New Drugs in Respiratory Medicine, New Insights from Clinical Practice and Guidelines. ''Respiration'' is the official journal of the Swiss Society for Pneumology (SGP) and also home to the European Association for Bronchology and Interventional Pulmonology (EABIP), which occupies a dedicated section on Interventional Pulmonology in the journal. This modern mix of different features and a stringent peer-review process by a dedicated editorial board make ''Respiration'' a complete guide to progress in thoracic medicine.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信