优化雾的空气清洁性能

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
Petar Todorov, Ognyan Ivanov, Ismail Gultepe, Martin Agelin-Chaab, José Luis Pérez-Díaz, Tanja Dreischuh, Kostadin Kostadinov
{"title":"优化雾的空气清洁性能","authors":"Petar Todorov,&nbsp;Ognyan Ivanov,&nbsp;Ismail Gultepe,&nbsp;Martin Agelin-Chaab,&nbsp;José Luis Pérez-Díaz,&nbsp;Tanja Dreischuh,&nbsp;Kostadin Kostadinov","doi":"10.1007/s41810-024-00220-0","DOIUrl":null,"url":null,"abstract":"<div><p>Fog droplets are very often used as a cleaning agent when air pollution can be dangerous for health conditions and ecosystem. This work presents a new system to optimize the cleaning properties of fog by tuning its microphysical parameters. For this purpose, a newly developed system, which is based on the electromagnetic echo effect (EMEE) sensor, is used to detect the most efficient interaction between fog and impurities, i.e., which fog droplets can be used to most effectively clean a certain type of pollutant from the air. Fog droplet spectra controlled by the nozzle pressure system can be used to effectively remove pollutants from the air. For this purpose, an automated system for aerosol generation can allow an accurate control over the fog microphysical parameters and the use of fluids with specific concentrations of pulverized chemical compounds. Fog droplet size distribution is controlled by the feeding gas pressure at the nozzle and chemical simulants. The experimental results showed that the microphysical parameters (MP) are directly related to the impurity of species used in the cleanup simulation process. The MP parameters of fog are liquid water content (LWC), droplet mean radius (<i>R</i><sub><i>m</i></sub>), droplet number concentration (<i>N</i><sub><i>d</i></sub>), and both aerosol type and mass concentration. In the lab testing, harmless simulants of CBRN (chemical, biological, radiological and nuclear) species were used. During the tests, fog droplet size distribution is controlled by the air pressure at the nozzle and simulants. It is concluded that an integrated fog generator system (IFGS) with EMEE sensor developed in the current work can be utilized broadly to control fog microphysical parameters, leading to an optimum aerosol/chemical species’ cleaning process.</p></div>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s41810-024-00220-0.pdf","citationCount":"0","resultStr":"{\"title\":\"Optimization of the Air Cleaning Properties of Fog\",\"authors\":\"Petar Todorov,&nbsp;Ognyan Ivanov,&nbsp;Ismail Gultepe,&nbsp;Martin Agelin-Chaab,&nbsp;José Luis Pérez-Díaz,&nbsp;Tanja Dreischuh,&nbsp;Kostadin Kostadinov\",\"doi\":\"10.1007/s41810-024-00220-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Fog droplets are very often used as a cleaning agent when air pollution can be dangerous for health conditions and ecosystem. This work presents a new system to optimize the cleaning properties of fog by tuning its microphysical parameters. For this purpose, a newly developed system, which is based on the electromagnetic echo effect (EMEE) sensor, is used to detect the most efficient interaction between fog and impurities, i.e., which fog droplets can be used to most effectively clean a certain type of pollutant from the air. Fog droplet spectra controlled by the nozzle pressure system can be used to effectively remove pollutants from the air. For this purpose, an automated system for aerosol generation can allow an accurate control over the fog microphysical parameters and the use of fluids with specific concentrations of pulverized chemical compounds. Fog droplet size distribution is controlled by the feeding gas pressure at the nozzle and chemical simulants. The experimental results showed that the microphysical parameters (MP) are directly related to the impurity of species used in the cleanup simulation process. The MP parameters of fog are liquid water content (LWC), droplet mean radius (<i>R</i><sub><i>m</i></sub>), droplet number concentration (<i>N</i><sub><i>d</i></sub>), and both aerosol type and mass concentration. In the lab testing, harmless simulants of CBRN (chemical, biological, radiological and nuclear) species were used. During the tests, fog droplet size distribution is controlled by the air pressure at the nozzle and simulants. It is concluded that an integrated fog generator system (IFGS) with EMEE sensor developed in the current work can be utilized broadly to control fog microphysical parameters, leading to an optimum aerosol/chemical species’ cleaning process.</p></div>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-03-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://link.springer.com/content/pdf/10.1007/s41810-024-00220-0.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s41810-024-00220-0\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"93","ListUrlMain":"https://link.springer.com/article/10.1007/s41810-024-00220-0","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

当空气污染对健康状况和生态系统造成危害时,雾滴通常被用作清洁剂。本研究提出了一种新系统,可通过调整雾滴的微物理参数来优化其清洁性能。为此,新开发的系统基于电磁回波效应(EMEE)传感器,用于检测雾与杂质之间最有效的相互作用,即哪种雾滴可用于最有效地清洁空气中的某类污染物。由喷嘴压力系统控制的雾滴光谱可用于有效清除空气中的污染物。为此,气溶胶生成自动化系统可以精确控制雾的微物理参数,并使用具有特定浓度的粉化化合物流体。雾滴大小分布由喷嘴处的进气压力和化学模拟物控制。实验结果表明,微物理参数(MP)与净化模拟过程中使用的物种杂质直接相关。雾的微物理参数包括液态水含量(LWC)、液滴平均半径(Rm)、液滴数量浓度(Nd)以及气溶胶类型和质量浓度。在实验室测试中,使用了 CBRN(化学、生物、辐射和核)物种的无害模拟物。测试期间,雾滴大小分布由喷嘴和模拟物的气压控制。结论是,当前工作中开发的带有 EMEE 传感器的集成雾发生器系统(IFGS)可广泛用于控制雾的微物理参数,从而实现最佳的气溶胶/化学物质清洁过程。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimization of the Air Cleaning Properties of Fog

Fog droplets are very often used as a cleaning agent when air pollution can be dangerous for health conditions and ecosystem. This work presents a new system to optimize the cleaning properties of fog by tuning its microphysical parameters. For this purpose, a newly developed system, which is based on the electromagnetic echo effect (EMEE) sensor, is used to detect the most efficient interaction between fog and impurities, i.e., which fog droplets can be used to most effectively clean a certain type of pollutant from the air. Fog droplet spectra controlled by the nozzle pressure system can be used to effectively remove pollutants from the air. For this purpose, an automated system for aerosol generation can allow an accurate control over the fog microphysical parameters and the use of fluids with specific concentrations of pulverized chemical compounds. Fog droplet size distribution is controlled by the feeding gas pressure at the nozzle and chemical simulants. The experimental results showed that the microphysical parameters (MP) are directly related to the impurity of species used in the cleanup simulation process. The MP parameters of fog are liquid water content (LWC), droplet mean radius (Rm), droplet number concentration (Nd), and both aerosol type and mass concentration. In the lab testing, harmless simulants of CBRN (chemical, biological, radiological and nuclear) species were used. During the tests, fog droplet size distribution is controlled by the air pressure at the nozzle and simulants. It is concluded that an integrated fog generator system (IFGS) with EMEE sensor developed in the current work can be utilized broadly to control fog microphysical parameters, leading to an optimum aerosol/chemical species’ cleaning process.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信