利用 cn-85 、cr-39 和 lr-115 核轨道探测器进行紫外线辐射剂量测定

Q4 Earth and Planetary Sciences
Firas Al-Jomaily, H. Al-jobouri, Ahmed Mheemeed
{"title":"利用 cn-85 、cr-39 和 lr-115 核轨道探测器进行紫外线辐射剂量测定","authors":"Firas Al-Jomaily, H. Al-jobouri, Ahmed Mheemeed","doi":"10.24996/iraqijournalofscience.v53i3.12754","DOIUrl":null,"url":null,"abstract":"Ultraviolet radiation dosimetry was determined by using CN-85 , CR-39 ,LR-115 nuclear track detectors – NTD with measuring of ; number of track-NT , etching time-TB , nuclear track diameter - DT and etching velocity -VD . By this study appear the increasing in etching time-TB of NTD samples which irradiated by UV-radiation do not pure effect on the number of track - NT , comparing with un-irradiated samples . The increasing in UV-irradiation make decreasing in etching time- Topt for CR-39 , CN-85 , LR-115 nuclear track detectors with percent of 20% , 25% , 50% respectively , comparing with un– irradiated sample at the radiation dose 3.77x103 erg /mm2 . . The increasing of irradiation dose make increasing in nuclear track diameter-DT with increase in etching time-TB at the radiation dose 300x103erg / mm2 for LR-115 detector . This study showing there was increasing in the percent value of etching velocity -VB with increasing inradiation dose for CR-39 , CN-85 . The increasing in nuclear track diameter- DTwith increasing in radiation dose was appearing as a resulted of energy of radiationand producted free radicals which interact with chemical etching solution . Thisstudy optioned by using nuclear track detectors CN-85 , CR-39 for determinationthe radiation dosimetry through measuring of etching velocity -VB butter than LR-115 detector","PeriodicalId":14698,"journal":{"name":"Iraqi Journal of Science","volume":"15 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"ULTRAVIOLET RADIATION DOSIMETRY BY USING OF CN-85 , CR-39, LR-115 NUCLEAR TRACK DETECTORS\",\"authors\":\"Firas Al-Jomaily, H. Al-jobouri, Ahmed Mheemeed\",\"doi\":\"10.24996/iraqijournalofscience.v53i3.12754\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Ultraviolet radiation dosimetry was determined by using CN-85 , CR-39 ,LR-115 nuclear track detectors – NTD with measuring of ; number of track-NT , etching time-TB , nuclear track diameter - DT and etching velocity -VD . By this study appear the increasing in etching time-TB of NTD samples which irradiated by UV-radiation do not pure effect on the number of track - NT , comparing with un-irradiated samples . The increasing in UV-irradiation make decreasing in etching time- Topt for CR-39 , CN-85 , LR-115 nuclear track detectors with percent of 20% , 25% , 50% respectively , comparing with un– irradiated sample at the radiation dose 3.77x103 erg /mm2 . . The increasing of irradiation dose make increasing in nuclear track diameter-DT with increase in etching time-TB at the radiation dose 300x103erg / mm2 for LR-115 detector . This study showing there was increasing in the percent value of etching velocity -VB with increasing inradiation dose for CR-39 , CN-85 . The increasing in nuclear track diameter- DTwith increasing in radiation dose was appearing as a resulted of energy of radiationand producted free radicals which interact with chemical etching solution . Thisstudy optioned by using nuclear track detectors CN-85 , CR-39 for determinationthe radiation dosimetry through measuring of etching velocity -VB butter than LR-115 detector\",\"PeriodicalId\":14698,\"journal\":{\"name\":\"Iraqi Journal of Science\",\"volume\":\"15 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iraqi Journal of Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24996/iraqijournalofscience.v53i3.12754\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Earth and Planetary Sciences\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iraqi Journal of Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24996/iraqijournalofscience.v53i3.12754","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Earth and Planetary Sciences","Score":null,"Total":0}
引用次数: 0

摘要

紫外线辐射剂量测定是通过使用 CN-85 、CR-39 和 LR-115 核轨道探测器(NTD)进行的,测量内容包括:轨道数-NT、蚀刻时间-TB、核轨道直径-DT 和蚀刻速度-VD。通过这项研究发现,与未经过紫外线辐照的样品相比,经过紫外线辐照的 NTD 样品的蚀刻时间-TB 的增加对轨道数-NT 没有纯粹的影响。在辐照剂量为 3.77x103erg / mm2 时,与未辐照样品相比,CR-39、CN-85 和 LR-115 核轨道探测器的紫外辐照剂量增加使蚀刻时间 Topt 分别减少 20%、25% 和 50%。 在辐照剂量为 300x103erg / mm2 时,LR-115 探测器的辐照剂量增加使核轨道直径-DT 增加,蚀刻时间-TB 增加。这项研究表明,随着辐照剂量的增加,CR-39 和 CN-85 的蚀刻速度-VB 的百分比值也在增加。随着辐照剂量的增加,核轨道直径-DT也随之增加,这是辐照能量和产生的自由基与化学蚀刻溶液相互作用的结果。与 LR-115 探测器相比,本研究选择使用核轨道探测器 CN-85 和 CR-39 通过测量蚀刻速度 -VB 黄油来确定辐射剂量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
ULTRAVIOLET RADIATION DOSIMETRY BY USING OF CN-85 , CR-39, LR-115 NUCLEAR TRACK DETECTORS
Ultraviolet radiation dosimetry was determined by using CN-85 , CR-39 ,LR-115 nuclear track detectors – NTD with measuring of ; number of track-NT , etching time-TB , nuclear track diameter - DT and etching velocity -VD . By this study appear the increasing in etching time-TB of NTD samples which irradiated by UV-radiation do not pure effect on the number of track - NT , comparing with un-irradiated samples . The increasing in UV-irradiation make decreasing in etching time- Topt for CR-39 , CN-85 , LR-115 nuclear track detectors with percent of 20% , 25% , 50% respectively , comparing with un– irradiated sample at the radiation dose 3.77x103 erg /mm2 . . The increasing of irradiation dose make increasing in nuclear track diameter-DT with increase in etching time-TB at the radiation dose 300x103erg / mm2 for LR-115 detector . This study showing there was increasing in the percent value of etching velocity -VB with increasing inradiation dose for CR-39 , CN-85 . The increasing in nuclear track diameter- DTwith increasing in radiation dose was appearing as a resulted of energy of radiationand producted free radicals which interact with chemical etching solution . Thisstudy optioned by using nuclear track detectors CN-85 , CR-39 for determinationthe radiation dosimetry through measuring of etching velocity -VB butter than LR-115 detector
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Iraqi Journal of Science
Iraqi Journal of Science Chemistry-Chemistry (all)
CiteScore
1.50
自引率
0.00%
发文量
241
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信