{"title":"计算机辅助手术中牙科植入物定位的准确性:体外研究。","authors":"","doi":"10.1016/j.jormas.2024.101828","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><div><span>The aim of this study is to presents an experimental method for surgical guide confection using an intraoral scanner to obtain a 3D model of the patient's complete denture and compare its accuracy with the conventional methodology using </span>computed tomography.</div></div><div><h3>Study design</h3><div>This prospective in-vitro study used 30 polyurethane<span><span> pre-manufactured mandibles which were divided into two groups, conventional technique (group I) and a new method using intraoral scanner (group II), establishing the virtually planned position of the </span>dental implants as a control group, considered as the gold standard for postoperative comparison.</span></div></div><div><h3>Results</h3><div>The difference between these methods is close to zero and not statistically significant (<em>p</em><span> &gt; 0.05), being heigh deviation (Xh) with p:0.130 and angulation difference of dental implants between the groups (Ang) with p:0.396.</span></div></div><div><h3>Conclusion</h3><div>The acquisition of stereolithography image of the prosthesis using an intraoral scanner has a clinically acceptable accuracy, being in agreement with the conventional method.</div></div>","PeriodicalId":55993,"journal":{"name":"Journal of Stomatology Oral and Maxillofacial Surgery","volume":"125 5","pages":"Article 101828"},"PeriodicalIF":1.8000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accuracy of dental implants positioning in computer-assisted surgeries: In vitro study\",\"authors\":\"\",\"doi\":\"10.1016/j.jormas.2024.101828\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objectives</h3><div><span>The aim of this study is to presents an experimental method for surgical guide confection using an intraoral scanner to obtain a 3D model of the patient's complete denture and compare its accuracy with the conventional methodology using </span>computed tomography.</div></div><div><h3>Study design</h3><div>This prospective in-vitro study used 30 polyurethane<span><span> pre-manufactured mandibles which were divided into two groups, conventional technique (group I) and a new method using intraoral scanner (group II), establishing the virtually planned position of the </span>dental implants as a control group, considered as the gold standard for postoperative comparison.</span></div></div><div><h3>Results</h3><div>The difference between these methods is close to zero and not statistically significant (<em>p</em><span> &gt; 0.05), being heigh deviation (Xh) with p:0.130 and angulation difference of dental implants between the groups (Ang) with p:0.396.</span></div></div><div><h3>Conclusion</h3><div>The acquisition of stereolithography image of the prosthesis using an intraoral scanner has a clinically acceptable accuracy, being in agreement with the conventional method.</div></div>\",\"PeriodicalId\":55993,\"journal\":{\"name\":\"Journal of Stomatology Oral and Maxillofacial Surgery\",\"volume\":\"125 5\",\"pages\":\"Article 101828\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Stomatology Oral and Maxillofacial Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2468785524000648\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Stomatology Oral and Maxillofacial Surgery","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2468785524000648","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究旨在介绍一种使用口内扫描仪获得患者全口义齿三维模型的手术导板制作实验方法,并将其准确性与使用计算机断层扫描的传统方法进行比较:这项前瞻性体外研究使用了 30 个聚氨酯预制下颌骨,将其分为两组,即传统技术组(I 组)和使用口内扫描仪的新方法组(II 组):结果:这些方法之间的差异接近零,无统计学意义(P>0.05),其中高偏差(Xh)P:0.130,组间种植体角度差异(Ang)P:0.396:使用口内扫描仪获取修复体的立体光刻图像在临床上具有可接受的准确性,与传统方法一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Accuracy of dental implants positioning in computer-assisted surgeries: In vitro study

Objectives

The aim of this study is to presents an experimental method for surgical guide confection using an intraoral scanner to obtain a 3D model of the patient's complete denture and compare its accuracy with the conventional methodology using computed tomography.

Study design

This prospective in-vitro study used 30 polyurethane pre-manufactured mandibles which were divided into two groups, conventional technique (group I) and a new method using intraoral scanner (group II), establishing the virtually planned position of the dental implants as a control group, considered as the gold standard for postoperative comparison.

Results

The difference between these methods is close to zero and not statistically significant (p > 0.05), being heigh deviation (Xh) with p:0.130 and angulation difference of dental implants between the groups (Ang) with p:0.396.

Conclusion

The acquisition of stereolithography image of the prosthesis using an intraoral scanner has a clinically acceptable accuracy, being in agreement with the conventional method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Stomatology Oral and Maxillofacial Surgery
Journal of Stomatology Oral and Maxillofacial Surgery Surgery, Dentistry, Oral Surgery and Medicine, Otorhinolaryngology and Facial Plastic Surgery
CiteScore
2.30
自引率
9.10%
发文量
0
审稿时长
23 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信