使用 5-Ethibond 的缝合桥技术:治疗髌骨下极骨折的有效方法。

IF 1.4 Q3 ORTHOPEDICS
Orthopedic Reviews Pub Date : 2024-03-17 eCollection Date: 2024-01-01 DOI:10.52965/001c.94275
Jinlong Hu, Jiale Zhang, Pei Zhang, Jingcheng Wang, Jinshan He, Pengtao Chen, Yuan Liang
{"title":"使用 5-Ethibond 的缝合桥技术:治疗髌骨下极骨折的有效方法。","authors":"Jinlong Hu, Jiale Zhang, Pei Zhang, Jingcheng Wang, Jinshan He, Pengtao Chen, Yuan Liang","doi":"10.52965/001c.94275","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Infrapatellar pole fractures are challenging injuries that require appropriate treatment to ensure optimal functional outcomes. This study aimed to introduce the application of the Suture Bridge technique using the 5-Ethibond for the treatment of infrapatellar patella fracture.</p><p><strong>Methods: </strong>Five cases of infrapatellar pole fracture that were treated at our institution between February 2020 and September 2021. The patients included one male and four females, with an average age of 66 years (range: 60-77 years). All patients were treated with the Suture Bridge technique using the 5-Ethibond to preserve the infrapatellar pole.</p><p><strong>Results: </strong>The average operative time was 64 min (range: 50-80 min). The average blood loss during surgery was 51 mL (range: 40-60 mL). All cases demonstrated fracture healing at an average of 10 weeks (range 8-12) after surgery. The patients were followed up for an average period of 14.8 months (8-22). No wound infection or second displacement of fracture fragment was found. Full range of motion was restored in all patients within 12-14 weeks after surgery. None of the patients complained of anterior knee pain.</p><p><strong>Conclusions: </strong>Based on the findings of the study, it appears that the Suture Bridge technique using 5-Ethibond is a promising and viable option for the treatment of infrapatellar pole fractures.</p>","PeriodicalId":19669,"journal":{"name":"Orthopedic Reviews","volume":"16 ","pages":"94275"},"PeriodicalIF":1.4000,"publicationDate":"2024-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10950202/pdf/","citationCount":"0","resultStr":"{\"title\":\"Suture Bridge Technique with 5-Ethibond: A Promising Approach for Infrapatellar Pole Fracture Treatment.\",\"authors\":\"Jinlong Hu, Jiale Zhang, Pei Zhang, Jingcheng Wang, Jinshan He, Pengtao Chen, Yuan Liang\",\"doi\":\"10.52965/001c.94275\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Infrapatellar pole fractures are challenging injuries that require appropriate treatment to ensure optimal functional outcomes. This study aimed to introduce the application of the Suture Bridge technique using the 5-Ethibond for the treatment of infrapatellar patella fracture.</p><p><strong>Methods: </strong>Five cases of infrapatellar pole fracture that were treated at our institution between February 2020 and September 2021. The patients included one male and four females, with an average age of 66 years (range: 60-77 years). All patients were treated with the Suture Bridge technique using the 5-Ethibond to preserve the infrapatellar pole.</p><p><strong>Results: </strong>The average operative time was 64 min (range: 50-80 min). The average blood loss during surgery was 51 mL (range: 40-60 mL). All cases demonstrated fracture healing at an average of 10 weeks (range 8-12) after surgery. The patients were followed up for an average period of 14.8 months (8-22). No wound infection or second displacement of fracture fragment was found. Full range of motion was restored in all patients within 12-14 weeks after surgery. None of the patients complained of anterior knee pain.</p><p><strong>Conclusions: </strong>Based on the findings of the study, it appears that the Suture Bridge technique using 5-Ethibond is a promising and viable option for the treatment of infrapatellar pole fractures.</p>\",\"PeriodicalId\":19669,\"journal\":{\"name\":\"Orthopedic Reviews\",\"volume\":\"16 \",\"pages\":\"94275\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-03-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10950202/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Orthopedic Reviews\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52965/001c.94275\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthopedic Reviews","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52965/001c.94275","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

目的:髌骨下极骨折是一种具有挑战性的损伤,需要适当的治疗以确保最佳的功能结果。本研究旨在介绍使用 5-Ethibond 缝合桥技术治疗髌骨下极骨折的应用:2020年2月至2021年9月期间在我院接受治疗的5例髌骨下极骨折患者。患者包括一名男性和四名女性,平均年龄为 66 岁(范围:60-77 岁)。所有患者均采用缝合桥技术,使用5-Ethibond保留髌骨下极:平均手术时间为 64 分钟(50-80 分钟不等)。手术中的平均失血量为 51 毫升(范围:40-60 毫升)。所有病例平均在术后 10 周(8-12 周)骨折愈合。对患者的随访时间平均为 14.8 个月(8-22 个月)。未发现伤口感染或骨折片二次移位。所有患者均在术后 12-14 周内恢复了完全活动范围。没有一名患者抱怨膝关节前部疼痛:根据研究结果,使用5-Ethibond的缝合桥技术似乎是治疗髌骨下极骨折的一种有前途的可行方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Suture Bridge Technique with 5-Ethibond: A Promising Approach for Infrapatellar Pole Fracture Treatment.

Purpose: Infrapatellar pole fractures are challenging injuries that require appropriate treatment to ensure optimal functional outcomes. This study aimed to introduce the application of the Suture Bridge technique using the 5-Ethibond for the treatment of infrapatellar patella fracture.

Methods: Five cases of infrapatellar pole fracture that were treated at our institution between February 2020 and September 2021. The patients included one male and four females, with an average age of 66 years (range: 60-77 years). All patients were treated with the Suture Bridge technique using the 5-Ethibond to preserve the infrapatellar pole.

Results: The average operative time was 64 min (range: 50-80 min). The average blood loss during surgery was 51 mL (range: 40-60 mL). All cases demonstrated fracture healing at an average of 10 weeks (range 8-12) after surgery. The patients were followed up for an average period of 14.8 months (8-22). No wound infection or second displacement of fracture fragment was found. Full range of motion was restored in all patients within 12-14 weeks after surgery. None of the patients complained of anterior knee pain.

Conclusions: Based on the findings of the study, it appears that the Suture Bridge technique using 5-Ethibond is a promising and viable option for the treatment of infrapatellar pole fractures.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Orthopedic Reviews
Orthopedic Reviews ORTHOPEDICS-
CiteScore
2.70
自引率
4.80%
发文量
122
审稿时长
10 weeks
期刊介绍: Orthopedic Reviews is an Open Access, online-only, peer-reviewed journal that considers articles concerned with any aspect of orthopedics, as well as diagnosis and treatment, trauma, surgical procedures, arthroscopy, sports medicine, rehabilitation, pediatric and geriatric orthopedics. All bone-related molecular and cell biology, genetics, pathophysiology and epidemiology papers are also welcome. The journal publishes original articles, brief reports, reviews and case reports of general interest.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信