成人 CE-Chirp ABR 反应阈值与纯音听力阈值的相关性分析和比较。

Q3 Medicine
He-Ying Cheng, Yun-Ge Zhang, Yan Chen, Sun Yin, Ming Lü, Chun-Xiao Li
{"title":"成人 CE-Chirp ABR 反应阈值与纯音听力阈值的相关性分析和比较。","authors":"He-Ying Cheng, Yun-Ge Zhang, Yan Chen, Sun Yin, Ming Lü, Chun-Xiao Li","doi":"10.12116/j.issn.1004-5619.2021.210101","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To study the application of CE-Chirp in the evaluation of hearing impairment in forensic medicine by testing the auditory brainstem response (ABR) in adults using CE-Chirp to analyze the relationship between the V-wave response threshold of CE-Chirp ABR test and the pure tone hearing threshold.</p><p><strong>Methods: </strong>Subjects (aged 20-77 with a total of 100 ears) who underwent CE-Chirp ABR test in Changzhou De'an Hospital from January 2018 to June 2019 were selected to obtain the V-wave response threshold, and pure tone air conduction hearing threshold tests were conducted at 0.5, 1.0, 2.0 and 4.0 kHz, respectively, to obtain pure tone listening threshold. The differences and statistical differences between the average pure tone hearing threshold and V-wave response threshold were compared in different hearing levels and different age groups. The correlation, differences and statistical differences between the two tests at each frequency were analyzed for all subjects. The linear regression equation for estimating pure tone hearing threshold for all subjects CE-Chirp ABR V-wave response threshold was established, and the feasibility of the equation was tested.</p><p><strong>Results: </strong>There was no statistical significance in the CE-Chirp ABR response threshold and pure tone hearing threshold difference between different hearing level groups and different age groups (<i>P></i>0.05). There was a good correlation between adult CE-Chirp ABR V-wave response threshold and pure tone hearing threshold with statistical significance (<i>P</i><0.05), and linear regression analysis showed a significant linear correlation between the two (<i>P</i><0.05).</p><p><strong>Conclusions: </strong>The use of CE-Chirp ABR V-wave response threshold can be used to evaluate subjects' pure tone hearing threshold under certain conditions, and can be used as an audiological test method for forensic hearing impairment assessment.</p>","PeriodicalId":12317,"journal":{"name":"法医学杂志","volume":"40 1","pages":"15-19"},"PeriodicalIF":0.0000,"publicationDate":"2024-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Correlation Analysis and Comparison of Adult CE-Chirp ABR Response Threshold and Pure Tone Hearing Threshold.\",\"authors\":\"He-Ying Cheng, Yun-Ge Zhang, Yan Chen, Sun Yin, Ming Lü, Chun-Xiao Li\",\"doi\":\"10.12116/j.issn.1004-5619.2021.210101\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To study the application of CE-Chirp in the evaluation of hearing impairment in forensic medicine by testing the auditory brainstem response (ABR) in adults using CE-Chirp to analyze the relationship between the V-wave response threshold of CE-Chirp ABR test and the pure tone hearing threshold.</p><p><strong>Methods: </strong>Subjects (aged 20-77 with a total of 100 ears) who underwent CE-Chirp ABR test in Changzhou De'an Hospital from January 2018 to June 2019 were selected to obtain the V-wave response threshold, and pure tone air conduction hearing threshold tests were conducted at 0.5, 1.0, 2.0 and 4.0 kHz, respectively, to obtain pure tone listening threshold. The differences and statistical differences between the average pure tone hearing threshold and V-wave response threshold were compared in different hearing levels and different age groups. The correlation, differences and statistical differences between the two tests at each frequency were analyzed for all subjects. The linear regression equation for estimating pure tone hearing threshold for all subjects CE-Chirp ABR V-wave response threshold was established, and the feasibility of the equation was tested.</p><p><strong>Results: </strong>There was no statistical significance in the CE-Chirp ABR response threshold and pure tone hearing threshold difference between different hearing level groups and different age groups (<i>P></i>0.05). There was a good correlation between adult CE-Chirp ABR V-wave response threshold and pure tone hearing threshold with statistical significance (<i>P</i><0.05), and linear regression analysis showed a significant linear correlation between the two (<i>P</i><0.05).</p><p><strong>Conclusions: </strong>The use of CE-Chirp ABR V-wave response threshold can be used to evaluate subjects' pure tone hearing threshold under certain conditions, and can be used as an audiological test method for forensic hearing impairment assessment.</p>\",\"PeriodicalId\":12317,\"journal\":{\"name\":\"法医学杂志\",\"volume\":\"40 1\",\"pages\":\"15-19\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"法医学杂志\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.12116/j.issn.1004-5619.2021.210101\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"法医学杂志","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12116/j.issn.1004-5619.2021.210101","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:研究 CE-Chirp 在法医学听力障碍评估中的应用:通过使用CE-Chirp测试成人听性脑干反应(ABR),分析CE-Chirp ABR测试V波反应阈值与纯音听阈的关系,研究CE-Chirp在法医学听力障碍评估中的应用:选取2018年1月-2019年6月在常州德安医院进行CE-Chirp ABR测试的受试者(年龄20-77岁,共100耳),分别在0.5、1.0、2.0、4.0 kHz进行纯音气导听阈测试,获得V波反应阈值,获得纯音听阈。比较了不同听力水平和不同年龄组的平均纯音听阈与 V 波反应阈之间的差异和统计学差异。分析了所有受试者在每个频率上两次测试的相关性、差异和统计差异。建立了估计所有受试者 CE-Chirp ABR V 波反应阈值纯音听阈的线性回归方程,并检验了方程的可行性:不同听力水平组和不同年龄组的 CE-Chirp ABR 反应阈和纯音听阈差异无统计学意义(P>0.05)。成人 CE-Chirp ABR V 波反应阈值与纯音听阈之间存在良好的相关性,具有统计学意义(PPC 结论:使用CE-Chirp ABR V波反应阈可以在一定条件下评估受试者的纯音听阈,可作为法医听力损伤评估的听力学测试方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Correlation Analysis and Comparison of Adult CE-Chirp ABR Response Threshold and Pure Tone Hearing Threshold.

Objectives: To study the application of CE-Chirp in the evaluation of hearing impairment in forensic medicine by testing the auditory brainstem response (ABR) in adults using CE-Chirp to analyze the relationship between the V-wave response threshold of CE-Chirp ABR test and the pure tone hearing threshold.

Methods: Subjects (aged 20-77 with a total of 100 ears) who underwent CE-Chirp ABR test in Changzhou De'an Hospital from January 2018 to June 2019 were selected to obtain the V-wave response threshold, and pure tone air conduction hearing threshold tests were conducted at 0.5, 1.0, 2.0 and 4.0 kHz, respectively, to obtain pure tone listening threshold. The differences and statistical differences between the average pure tone hearing threshold and V-wave response threshold were compared in different hearing levels and different age groups. The correlation, differences and statistical differences between the two tests at each frequency were analyzed for all subjects. The linear regression equation for estimating pure tone hearing threshold for all subjects CE-Chirp ABR V-wave response threshold was established, and the feasibility of the equation was tested.

Results: There was no statistical significance in the CE-Chirp ABR response threshold and pure tone hearing threshold difference between different hearing level groups and different age groups (P>0.05). There was a good correlation between adult CE-Chirp ABR V-wave response threshold and pure tone hearing threshold with statistical significance (P<0.05), and linear regression analysis showed a significant linear correlation between the two (P<0.05).

Conclusions: The use of CE-Chirp ABR V-wave response threshold can be used to evaluate subjects' pure tone hearing threshold under certain conditions, and can be used as an audiological test method for forensic hearing impairment assessment.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
法医学杂志
法医学杂志 Medicine-Pathology and Forensic Medicine
CiteScore
1.50
自引率
0.00%
发文量
0
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信