D A Thompson, M Bach, J J McAnany, M Šuštar Habjan, S Viswanathan, A G Robson
{"title":"ISCEV 临床模式视网膜电图标准(2024 年更新)。","authors":"D A Thompson, M Bach, J J McAnany, M Šuštar Habjan, S Viswanathan, A G Robson","doi":"10.1007/s10633-024-09970-1","DOIUrl":null,"url":null,"abstract":"<p><p>The pattern electroretinogram (PERG) is a localized retinal response evoked by a contrast-reversing pattern, usually a black and white checkerboard, which provides information about macular and retinal ganglion cell function. This document, from the International Society for Clinical Electrophysiology of Vision (ISCEV; www.iscev.org ) presents an updated and revised Standard for clinical PERG testing. This replaces the 2013 and all earlier versions. Minimum protocols for basic PERG stimuli, recording methods and reporting are specified, to promote consistency of methods for diagnosis and monitoring purposes, while responding to evolving clinical practices and technology. The main changes in the updated ISCEV Standard for clinical PERG include expanded guidance about large stimulus fields, stimulus parameters for simultaneous PERG and pattern visual evoked potential recording, baseline drift correction, and use of consistent ambient room lighting. These changes aim to provide a clinically relevant document about current practice which will facilitate good quality recordings and inter-laboratory comparisons.</p>","PeriodicalId":11207,"journal":{"name":"Documenta Ophthalmologica","volume":" ","pages":"75-85"},"PeriodicalIF":2.6000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10954931/pdf/","citationCount":"0","resultStr":"{\"title\":\"ISCEV standard for clinical pattern electroretinography (2024 update).\",\"authors\":\"D A Thompson, M Bach, J J McAnany, M Šuštar Habjan, S Viswanathan, A G Robson\",\"doi\":\"10.1007/s10633-024-09970-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The pattern electroretinogram (PERG) is a localized retinal response evoked by a contrast-reversing pattern, usually a black and white checkerboard, which provides information about macular and retinal ganglion cell function. This document, from the International Society for Clinical Electrophysiology of Vision (ISCEV; www.iscev.org ) presents an updated and revised Standard for clinical PERG testing. This replaces the 2013 and all earlier versions. Minimum protocols for basic PERG stimuli, recording methods and reporting are specified, to promote consistency of methods for diagnosis and monitoring purposes, while responding to evolving clinical practices and technology. The main changes in the updated ISCEV Standard for clinical PERG include expanded guidance about large stimulus fields, stimulus parameters for simultaneous PERG and pattern visual evoked potential recording, baseline drift correction, and use of consistent ambient room lighting. These changes aim to provide a clinically relevant document about current practice which will facilitate good quality recordings and inter-laboratory comparisons.</p>\",\"PeriodicalId\":11207,\"journal\":{\"name\":\"Documenta Ophthalmologica\",\"volume\":\" \",\"pages\":\"75-85\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10954931/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Documenta Ophthalmologica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10633-024-09970-1\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/15 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Documenta Ophthalmologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10633-024-09970-1","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/15 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
ISCEV standard for clinical pattern electroretinography (2024 update).
The pattern electroretinogram (PERG) is a localized retinal response evoked by a contrast-reversing pattern, usually a black and white checkerboard, which provides information about macular and retinal ganglion cell function. This document, from the International Society for Clinical Electrophysiology of Vision (ISCEV; www.iscev.org ) presents an updated and revised Standard for clinical PERG testing. This replaces the 2013 and all earlier versions. Minimum protocols for basic PERG stimuli, recording methods and reporting are specified, to promote consistency of methods for diagnosis and monitoring purposes, while responding to evolving clinical practices and technology. The main changes in the updated ISCEV Standard for clinical PERG include expanded guidance about large stimulus fields, stimulus parameters for simultaneous PERG and pattern visual evoked potential recording, baseline drift correction, and use of consistent ambient room lighting. These changes aim to provide a clinically relevant document about current practice which will facilitate good quality recordings and inter-laboratory comparisons.
期刊介绍:
Documenta Ophthalmologica is an official publication of the International Society for Clinical Electrophysiology of Vision. The purpose of the journal is to promote the understanding and application of clinical electrophysiology of vision. Documenta Ophthalmologica will publish reviews, research articles, technical notes, brief reports and case studies which inform the readers about basic and clinical sciences related to visual electrodiagnosis and means to improve diagnosis and clinical management of patients using visual electrophysiology. Studies may involve animals or humans. In either case appropriate care must be taken to follow the Declaration of Helsinki for human subject or appropriate humane standards of animal care (e.g., the ARVO standards on Animal Care and Use).