{"title":"提高全牙弓螺钉固位种植修复体制作的精确度和准确性:利用 Nexus iOS 扫描测量系统的病例报告。","authors":"Maryam Khalili","doi":"10.1563/aaid-joi-D-24-00019","DOIUrl":null,"url":null,"abstract":"<p><p>Achieving an accurate fit in a complete arch screw-retained implant prosthesis is paramount, regardless of whether analog or digital impressions are employed. In the context of complete arch implant prostheses, using intraoral scanners has sparked significant debate. However, recent advancements in scanner technology, specialized scan gauges meticulously calibrated for precise recording, and the implementation of appropriate scanning techniques have substantially improved the precision and accuracy of digital records. The Nexus iOS scan gauge system represents a pioneering approach, seamlessly integrating these optimization strategies into a purely digital workflow to fabricate complete arch screw-retained implant prostheses in edentulous patients. This case report elucidates the fabrication process of a complete arch screw-retained implant prosthesis that exhibited remarkable fitting accuracy and streamlined the treatment process to a mere 3 appointments. The patient reported high satisfaction with the efficient timeline, aesthetic appeal, and functional performance of the prosthesis. A distinctive advantage of this technique is the notable reduction in treatment steps compared to traditional procedures.</p>","PeriodicalId":50101,"journal":{"name":"Journal of Oral Implantology","volume":" ","pages":"160-165"},"PeriodicalIF":1.5000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Enhancing Precision and Efficiency in Fabricating Complete Arch Screw-Retained Implant Prosthesis: A Clinical Case Report Utilizing the Nexus iOS Scan Gauge System.\",\"authors\":\"Maryam Khalili\",\"doi\":\"10.1563/aaid-joi-D-24-00019\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Achieving an accurate fit in a complete arch screw-retained implant prosthesis is paramount, regardless of whether analog or digital impressions are employed. In the context of complete arch implant prostheses, using intraoral scanners has sparked significant debate. However, recent advancements in scanner technology, specialized scan gauges meticulously calibrated for precise recording, and the implementation of appropriate scanning techniques have substantially improved the precision and accuracy of digital records. The Nexus iOS scan gauge system represents a pioneering approach, seamlessly integrating these optimization strategies into a purely digital workflow to fabricate complete arch screw-retained implant prostheses in edentulous patients. This case report elucidates the fabrication process of a complete arch screw-retained implant prosthesis that exhibited remarkable fitting accuracy and streamlined the treatment process to a mere 3 appointments. The patient reported high satisfaction with the efficient timeline, aesthetic appeal, and functional performance of the prosthesis. A distinctive advantage of this technique is the notable reduction in treatment steps compared to traditional procedures.</p>\",\"PeriodicalId\":50101,\"journal\":{\"name\":\"Journal of Oral Implantology\",\"volume\":\" \",\"pages\":\"160-165\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Oral Implantology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1563/aaid-joi-D-24-00019\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Oral Implantology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1563/aaid-joi-D-24-00019","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Enhancing Precision and Efficiency in Fabricating Complete Arch Screw-Retained Implant Prosthesis: A Clinical Case Report Utilizing the Nexus iOS Scan Gauge System.
Achieving an accurate fit in a complete arch screw-retained implant prosthesis is paramount, regardless of whether analog or digital impressions are employed. In the context of complete arch implant prostheses, using intraoral scanners has sparked significant debate. However, recent advancements in scanner technology, specialized scan gauges meticulously calibrated for precise recording, and the implementation of appropriate scanning techniques have substantially improved the precision and accuracy of digital records. The Nexus iOS scan gauge system represents a pioneering approach, seamlessly integrating these optimization strategies into a purely digital workflow to fabricate complete arch screw-retained implant prostheses in edentulous patients. This case report elucidates the fabrication process of a complete arch screw-retained implant prosthesis that exhibited remarkable fitting accuracy and streamlined the treatment process to a mere 3 appointments. The patient reported high satisfaction with the efficient timeline, aesthetic appeal, and functional performance of the prosthesis. A distinctive advantage of this technique is the notable reduction in treatment steps compared to traditional procedures.
期刊介绍:
The official publication of the American Academy of Implant Dentistry and of the American Academy of Implant Prosthodontics, is dedicated to providing valuable information to general dentists, oral surgeons, prosthodontists, periodontists, scientists, clinicians, laboratory owners and technicians, manufacturers, and educators. Implant basics, prosthetics, pharmaceuticals, the latest research in implantology, implant surgery, and advanced implant procedures are just some of the topics covered.