{"title":"分析锥形光纤表面等离子体共振生物传感器芯片的高扰动锥形轮廓。","authors":"Sanjeev Kumar Raghuwanshi","doi":"10.1109/TNB.2024.3376824","DOIUrl":null,"url":null,"abstract":"A numerical model based on the Transfer matrix method (TMM) is proposed for the first time to study the gold coated tapered fibre optic surface plasmon resonance (SPR) with eight different types of taper profiles namely linear, exponential-linear, Gaussian, quadratic, sinusoidal, error function type and highly perturbed taper profile so-called chirp type of profile. The performance in terms of sensitivity, full width at half maximum (FWHM), detection accuracy (D.A.), amplitude dip, and half power points are estimated with respect to tapering ratio and choices of taper profile. It is found that sensitivity increased almost linearly with the taper ratio of each taper choice for the account of the reduction of detection accuracy. It has been found that sensitivity is highest for the case of chirp taper profile and lowest for the case of quadratic taper profile at low taper ratio. In this study, the aqueous solution is considered for sensor development which is adulterated by biomolecules species like DNA, blood samples, etc.","PeriodicalId":13264,"journal":{"name":"IEEE Transactions on NanoBioscience","volume":"23 3","pages":"439-446"},"PeriodicalIF":3.7000,"publicationDate":"2024-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of Tapered Fibre Optic Surface Plasmon Resonance Bio-Sensor Chip With Highly Perturbed Taper Profiles\",\"authors\":\"Sanjeev Kumar Raghuwanshi\",\"doi\":\"10.1109/TNB.2024.3376824\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A numerical model based on the Transfer matrix method (TMM) is proposed for the first time to study the gold coated tapered fibre optic surface plasmon resonance (SPR) with eight different types of taper profiles namely linear, exponential-linear, Gaussian, quadratic, sinusoidal, error function type and highly perturbed taper profile so-called chirp type of profile. The performance in terms of sensitivity, full width at half maximum (FWHM), detection accuracy (D.A.), amplitude dip, and half power points are estimated with respect to tapering ratio and choices of taper profile. It is found that sensitivity increased almost linearly with the taper ratio of each taper choice for the account of the reduction of detection accuracy. It has been found that sensitivity is highest for the case of chirp taper profile and lowest for the case of quadratic taper profile at low taper ratio. In this study, the aqueous solution is considered for sensor development which is adulterated by biomolecules species like DNA, blood samples, etc.\",\"PeriodicalId\":13264,\"journal\":{\"name\":\"IEEE Transactions on NanoBioscience\",\"volume\":\"23 3\",\"pages\":\"439-446\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2024-03-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on NanoBioscience\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10471593/\",\"RegionNum\":4,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on NanoBioscience","FirstCategoryId":"99","ListUrlMain":"https://ieeexplore.ieee.org/document/10471593/","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Analysis of Tapered Fibre Optic Surface Plasmon Resonance Bio-Sensor Chip With Highly Perturbed Taper Profiles
A numerical model based on the Transfer matrix method (TMM) is proposed for the first time to study the gold coated tapered fibre optic surface plasmon resonance (SPR) with eight different types of taper profiles namely linear, exponential-linear, Gaussian, quadratic, sinusoidal, error function type and highly perturbed taper profile so-called chirp type of profile. The performance in terms of sensitivity, full width at half maximum (FWHM), detection accuracy (D.A.), amplitude dip, and half power points are estimated with respect to tapering ratio and choices of taper profile. It is found that sensitivity increased almost linearly with the taper ratio of each taper choice for the account of the reduction of detection accuracy. It has been found that sensitivity is highest for the case of chirp taper profile and lowest for the case of quadratic taper profile at low taper ratio. In this study, the aqueous solution is considered for sensor development which is adulterated by biomolecules species like DNA, blood samples, etc.
期刊介绍:
The IEEE Transactions on NanoBioscience reports on original, innovative and interdisciplinary work on all aspects of molecular systems, cellular systems, and tissues (including molecular electronics). Topics covered in the journal focus on a broad spectrum of aspects, both on foundations and on applications. Specifically, methods and techniques, experimental aspects, design and implementation, instrumentation and laboratory equipment, clinical aspects, hardware and software data acquisition and analysis and computer based modelling are covered (based on traditional or high performance computing - parallel computers or computer networks).