Theranova 与 FX80:对血液透析中贫血管理的影响。

IF 1.4 4区 医学 Q4 ENGINEERING, BIOMEDICAL
Tuncay Sahutoglu, Osman Erinc, Fevzi Necati Avsar
{"title":"Theranova 与 FX80:对血液透析中贫血管理的影响。","authors":"Tuncay Sahutoglu, Osman Erinc, Fevzi Necati Avsar","doi":"10.1177/03913988241236736","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Middle uremic toxins (MUTs) can cause anemia and erythropoietin hyporesponsiveness. Theranova dialyzers may improve anemia management by removing MUTs. Hence, the impact of Theranova dialyzers on erythropoietin responsiveness was studied.</p><p><strong>Methods: </strong>This exploratory single-center prospective observational study, encompassing 50 patients undergoing dialysis with either the Theranova-400 or FX80 membrane for 6 months, involved monthly tracking of hemoglobin levels, weight-adjusted erythropoiesis-stimulating agent (w-ESA) dosing, and erythropoietin resistance index (ERI), with ESA treatment decisions guided by a proprietary algorithm.</p><p><strong>Results: </strong>The groups were similar in terms of demographics and baseline laboratory test results. The median hemoglobin levels, w-ESA and ERI, were found to be similar between FX80 and Theranova-400 groups at both baseline (11.06 vs 10.57, <i>p</i> = 0.808; 92.3 vs 105.2, <i>p</i> = 0.838; 8.1 vs 10.48, <i>p</i> = 0.876) and the end of the study (11.43 vs 11.03, <i>p</i> = 0.076; 48.7 vs 71.5; 4.48 vs 6.41, <i>p</i> = 0.310), respectively. There was a trend toward lower w-ESA and ERI at the end of the study compared to baseline in both groups, but the difference was non-significant.</p><p><strong>Conclusions: </strong>Based on this study of 50 patients undergoing high-flux dialysis with near-target hemoglobin levels, switching to Theranova 400 dialyzers compared to FX80 dialyzers did not show statistically significant differences in maintaining hemoglobin levels, reducing ESA dose, or lowering ERI. The non-randomized design and small sample size limit the study's power to detect true differences. Larger, randomized trials are needed to confirm findings and definitively assess Theranova 400's benefits.</p>","PeriodicalId":13932,"journal":{"name":"International Journal of Artificial Organs","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Theranova versus FX80: The impact on anemia management in hemodialysis.\",\"authors\":\"Tuncay Sahutoglu, Osman Erinc, Fevzi Necati Avsar\",\"doi\":\"10.1177/03913988241236736\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Middle uremic toxins (MUTs) can cause anemia and erythropoietin hyporesponsiveness. Theranova dialyzers may improve anemia management by removing MUTs. Hence, the impact of Theranova dialyzers on erythropoietin responsiveness was studied.</p><p><strong>Methods: </strong>This exploratory single-center prospective observational study, encompassing 50 patients undergoing dialysis with either the Theranova-400 or FX80 membrane for 6 months, involved monthly tracking of hemoglobin levels, weight-adjusted erythropoiesis-stimulating agent (w-ESA) dosing, and erythropoietin resistance index (ERI), with ESA treatment decisions guided by a proprietary algorithm.</p><p><strong>Results: </strong>The groups were similar in terms of demographics and baseline laboratory test results. The median hemoglobin levels, w-ESA and ERI, were found to be similar between FX80 and Theranova-400 groups at both baseline (11.06 vs 10.57, <i>p</i> = 0.808; 92.3 vs 105.2, <i>p</i> = 0.838; 8.1 vs 10.48, <i>p</i> = 0.876) and the end of the study (11.43 vs 11.03, <i>p</i> = 0.076; 48.7 vs 71.5; 4.48 vs 6.41, <i>p</i> = 0.310), respectively. There was a trend toward lower w-ESA and ERI at the end of the study compared to baseline in both groups, but the difference was non-significant.</p><p><strong>Conclusions: </strong>Based on this study of 50 patients undergoing high-flux dialysis with near-target hemoglobin levels, switching to Theranova 400 dialyzers compared to FX80 dialyzers did not show statistically significant differences in maintaining hemoglobin levels, reducing ESA dose, or lowering ERI. The non-randomized design and small sample size limit the study's power to detect true differences. Larger, randomized trials are needed to confirm findings and definitively assess Theranova 400's benefits.</p>\",\"PeriodicalId\":13932,\"journal\":{\"name\":\"International Journal of Artificial Organs\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Artificial Organs\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/03913988241236736\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/03913988241236736","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/8 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:中型尿毒症毒素(MUT)可导致贫血和促红细胞生成素低反应性。Theranova 透析器可通过清除中段尿毒症毒素改善贫血管理。因此,我们研究了 Theranova 透析器对促红细胞生成素反应性的影响:这项探索性的单中心前瞻性观察研究包括 50 名接受 Theranova-400 或 FX80 膜透析的患者,为期 6 个月,每月跟踪血红蛋白水平、体重调整型促红细胞生成素(w-ESA)剂量和促红细胞生成素抵抗指数(ERI),并通过专有算法指导 ESA 治疗决策:两组患者的人口统计学和基线实验室检测结果相似。在基线(11.06 vs 10.57,p = 0.808;92.3 vs 105.2,p = 0.838;8.1 vs 10.48,p = 0.876)和研究结束时(11.43 vs 11.03,p = 0.076;48.7 vs 71.5;4.48 vs 6.41,p = 0.310),FX80 组和 Theranova-400 组的中位血红蛋白水平、w-ESA 和 ERI 都相似。与基线相比,两组患者在研究结束时的w-ESA和ERI均呈下降趋势,但差异不显著:根据这项对 50 名接受高通量透析且血红蛋白水平接近目标值的患者进行的研究,与 FX80 透析器相比,改用 Theranova 400 透析器在维持血红蛋白水平、减少 ESA 剂量或降低 ERI 方面没有统计学意义上的显著差异。非随机设计和样本量小限制了该研究检测真实差异的能力。需要更大规模的随机试验来证实研究结果,并明确评估 Theranova 400 的益处。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Theranova versus FX80: The impact on anemia management in hemodialysis.

Background: Middle uremic toxins (MUTs) can cause anemia and erythropoietin hyporesponsiveness. Theranova dialyzers may improve anemia management by removing MUTs. Hence, the impact of Theranova dialyzers on erythropoietin responsiveness was studied.

Methods: This exploratory single-center prospective observational study, encompassing 50 patients undergoing dialysis with either the Theranova-400 or FX80 membrane for 6 months, involved monthly tracking of hemoglobin levels, weight-adjusted erythropoiesis-stimulating agent (w-ESA) dosing, and erythropoietin resistance index (ERI), with ESA treatment decisions guided by a proprietary algorithm.

Results: The groups were similar in terms of demographics and baseline laboratory test results. The median hemoglobin levels, w-ESA and ERI, were found to be similar between FX80 and Theranova-400 groups at both baseline (11.06 vs 10.57, p = 0.808; 92.3 vs 105.2, p = 0.838; 8.1 vs 10.48, p = 0.876) and the end of the study (11.43 vs 11.03, p = 0.076; 48.7 vs 71.5; 4.48 vs 6.41, p = 0.310), respectively. There was a trend toward lower w-ESA and ERI at the end of the study compared to baseline in both groups, but the difference was non-significant.

Conclusions: Based on this study of 50 patients undergoing high-flux dialysis with near-target hemoglobin levels, switching to Theranova 400 dialyzers compared to FX80 dialyzers did not show statistically significant differences in maintaining hemoglobin levels, reducing ESA dose, or lowering ERI. The non-randomized design and small sample size limit the study's power to detect true differences. Larger, randomized trials are needed to confirm findings and definitively assess Theranova 400's benefits.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Artificial Organs
International Journal of Artificial Organs 医学-工程:生物医学
CiteScore
3.40
自引率
5.90%
发文量
92
审稿时长
3 months
期刊介绍: The International Journal of Artificial Organs (IJAO) publishes peer-reviewed research and clinical, experimental and theoretical, contributions to the field of artificial, bioartificial and tissue-engineered organs. The mission of the IJAO is to foster the development and optimization of artificial, bioartificial and tissue-engineered organs, for implantation or use in procedures, to treat functional deficits of all human tissues and organs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信