使用有限元分析法分析锁定钢板固定后犬桡骨的应力变化。

IF 1 2区 农林科学 Q3 VETERINARY SCIENCES
Norihiro Muroi, Sawako Murakami, Nobuo Kanno, Yasuji Harada, Yasushi Hara
{"title":"使用有限元分析法分析锁定钢板固定后犬桡骨的应力变化。","authors":"Norihiro Muroi, Sawako Murakami, Nobuo Kanno, Yasuji Harada, Yasushi Hara","doi":"10.1055/s-0044-1782194","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong> The aim of this study was to evaluate the stress changes in the radii beneath the locking plates (LP) of dogs implanted with LP using finite element analysis (FEA).</p><p><strong>Study design: </strong> The study included radii harvested from eight dogs. After computed tomography (CT) scans of the forelimb, the articular surface of the radius was fixed using resin. Material tests were conducted to identify the yield and fracture points and for verification with FEA. The CT data of the radius were imported into FEA software. The radii were classified into three groups based on the placement of the LP (nonplate placement, intact group; 1 mm above the radial surface, LP + 1 mm group; 3 mm above the radial surface, LP + 3 mm group). Equivalent, maximum, and minimum principal stresses and minimum principal strain were measured after FEA at the radial diaphysis beneath the plate.</p><p><strong>Results: </strong> In shell elements, the LP + 1 mm and LP + 3 mm groups showed a significantly lower maximum principal stress compared with the intact group. In solid elements, the LP + 1 mm and LP + 3 mm groups showed a significantly higher equivalent stress and a significantly lower maximum principal stress compared with the intact group.</p><p><strong>Conclusion: </strong> When an axial load is applied to the radius, LP placement reduces the tension stress on the cortical bone of the radius beneath the plate, possibly related to implant-induced osteoporosis and bone formation in the cortical bone beneath the plate.</p>","PeriodicalId":51204,"journal":{"name":"Veterinary and Comparative Orthopaedics and Traumatology","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Stress Changes in the Canine Radius after Locking Plate Fixation Using Finite Element Analysis.\",\"authors\":\"Norihiro Muroi, Sawako Murakami, Nobuo Kanno, Yasuji Harada, Yasushi Hara\",\"doi\":\"10.1055/s-0044-1782194\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong> The aim of this study was to evaluate the stress changes in the radii beneath the locking plates (LP) of dogs implanted with LP using finite element analysis (FEA).</p><p><strong>Study design: </strong> The study included radii harvested from eight dogs. After computed tomography (CT) scans of the forelimb, the articular surface of the radius was fixed using resin. Material tests were conducted to identify the yield and fracture points and for verification with FEA. The CT data of the radius were imported into FEA software. The radii were classified into three groups based on the placement of the LP (nonplate placement, intact group; 1 mm above the radial surface, LP + 1 mm group; 3 mm above the radial surface, LP + 3 mm group). Equivalent, maximum, and minimum principal stresses and minimum principal strain were measured after FEA at the radial diaphysis beneath the plate.</p><p><strong>Results: </strong> In shell elements, the LP + 1 mm and LP + 3 mm groups showed a significantly lower maximum principal stress compared with the intact group. In solid elements, the LP + 1 mm and LP + 3 mm groups showed a significantly higher equivalent stress and a significantly lower maximum principal stress compared with the intact group.</p><p><strong>Conclusion: </strong> When an axial load is applied to the radius, LP placement reduces the tension stress on the cortical bone of the radius beneath the plate, possibly related to implant-induced osteoporosis and bone formation in the cortical bone beneath the plate.</p>\",\"PeriodicalId\":51204,\"journal\":{\"name\":\"Veterinary and Comparative Orthopaedics and Traumatology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Veterinary and Comparative Orthopaedics and Traumatology\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0044-1782194\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/6 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary and Comparative Orthopaedics and Traumatology","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1055/s-0044-1782194","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/6 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究的目的是利用有限元分析(FEA)来评估植入锁定板(LP)的狗桡骨下方的应力变化:研究包括从八只狗身上采集的桡骨。在对前肢进行计算机断层扫描(CT)后,用树脂固定桡骨关节面。进行材料测试以确定屈服点和断裂点,并通过有限元分析进行验证。桡骨的 CT 数据被导入有限元分析软件。根据 LP 的放置位置将桡骨分为三组(无板放置,完整组;高出桡骨表面 1 毫米,LP + 1 毫米组;高出桡骨表面 3 毫米,LP + 3 毫米组)。在对钢板下方的桡骨干骺端进行有限元分析后,测量了等效、最大和最小主应力以及最小主应变:在壳元素中,LP + 1 mm 组和 LP + 3 mm 组的最大主应力明显低于完整组。在实体元件中,与完整组相比,LP + 1 mm 组和 LP + 3 mm 组的等效应力明显较高,最大主应力明显较低:结论:当对桡骨施加轴向载荷时,LP置入可降低钢板下方桡骨皮质骨的拉应力,这可能与植入物引起的骨质疏松和钢板下方皮质骨的骨形成有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Stress Changes in the Canine Radius after Locking Plate Fixation Using Finite Element Analysis.

Objective:  The aim of this study was to evaluate the stress changes in the radii beneath the locking plates (LP) of dogs implanted with LP using finite element analysis (FEA).

Study design:  The study included radii harvested from eight dogs. After computed tomography (CT) scans of the forelimb, the articular surface of the radius was fixed using resin. Material tests were conducted to identify the yield and fracture points and for verification with FEA. The CT data of the radius were imported into FEA software. The radii were classified into three groups based on the placement of the LP (nonplate placement, intact group; 1 mm above the radial surface, LP + 1 mm group; 3 mm above the radial surface, LP + 3 mm group). Equivalent, maximum, and minimum principal stresses and minimum principal strain were measured after FEA at the radial diaphysis beneath the plate.

Results:  In shell elements, the LP + 1 mm and LP + 3 mm groups showed a significantly lower maximum principal stress compared with the intact group. In solid elements, the LP + 1 mm and LP + 3 mm groups showed a significantly higher equivalent stress and a significantly lower maximum principal stress compared with the intact group.

Conclusion:  When an axial load is applied to the radius, LP placement reduces the tension stress on the cortical bone of the radius beneath the plate, possibly related to implant-induced osteoporosis and bone formation in the cortical bone beneath the plate.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.00
自引率
15.40%
发文量
49
审稿时长
18-36 weeks
期刊介绍: Veterinary and Comparative Orthopaedics and Traumatology (VCOT) is the most important single source for clinically relevant information in orthopaedics and neurosurgery available anywhere in the world today. It is unique in that it is truly comparative and there is an unrivalled mix of review articles and basic science amid the information that is immediately clinically relevant in veterinary surgery today.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信