使用和不使用自动管电压选择的双相全身多创伤 CT 方案的剂量长度积和图像质量比较。

IF 0.7 4区 医学 Q4 MEDICINE, RESEARCH & EXPERIMENTAL
Biomedical Papers-Olomouc Pub Date : 2024-11-01 Epub Date: 2024-03-04 DOI:10.5507/bp.2024.004
David Girsa, Karin Kremenova, Jiri Lukavsky, Lucie Sukupova, Hana Malikova
{"title":"使用和不使用自动管电压选择的双相全身多创伤 CT 方案的剂量长度积和图像质量比较。","authors":"David Girsa, Karin Kremenova, Jiri Lukavsky, Lucie Sukupova, Hana Malikova","doi":"10.5507/bp.2024.004","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aims: </strong>A significant source of man-made radiation is now linked to medical devices especially X-ray imaging based ones like CT scans which expose the body to cumulative ionizing radiation and thus attendant cancer risks. The aim of this study was to determine whether using a combination of Automatic Tube Current Modulation (ATCM) and Automatic Tube Voltage Selection (ATVS) during two-phase whole-body CT (2PWBCT) examinations would reduce the radiation dose while preserving the image quality.</p><p><strong>Patients and methods: </strong>This was a prospective, observational, single-centre study of 127 adult patients who had undergone the 2PWBCT polytraumatic protocol. All were examined on a Somatom Drive scanner (Siemens). The patients were divided into two groups: ATCM only (42 patients) and ATCM +ATVS (85 patients). Patients' arm positions during examination and the examination dose length product (DLP) values were recorded, as well the standard deviations (SD) of the density in reference areas on CT scans for the image quality assessment. The DLP values and image quality in the groups were compared using ANOVA.</p><p><strong>Results: </strong>Mean Total DLP (in mGy*cm): ATCM only: 3337 +/-797, ATCM+ATVS: 3402 +/-830; P=0.674. No effect of arm position (P=0.586). Mean density SD values in reference areas (in HU) in ATCM only: 49 +/-45, 15 +/-6, 9 +/-2, 12 +/-4, 10 +/-3, in ATCM+ATVS: 48 +/-45, 17 +/-6, 11 +/-3, 15 +/-6, 12 +/-4. SD values was higher in ATCM+ATVS group (P<0.001).</p><p><strong>Conclusion: </strong>Combination of ATVS and ATCM in polytraumatic 2PWBCT leads to no significant radiation load reduction compared with ATCM only but does lead to a slight degradation of image quality. The radiation load is significantly reduced if the patient has their arms behind the head when scanning, regardless of the activation of ATVS.</p>","PeriodicalId":55363,"journal":{"name":"Biomedical Papers-Olomouc","volume":" ","pages":"304-310"},"PeriodicalIF":0.7000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of dose length product and image quality of a biphasic whole-body polytrauma CT protocol with and without the automatic tube voltage selection.\",\"authors\":\"David Girsa, Karin Kremenova, Jiri Lukavsky, Lucie Sukupova, Hana Malikova\",\"doi\":\"10.5507/bp.2024.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and aims: </strong>A significant source of man-made radiation is now linked to medical devices especially X-ray imaging based ones like CT scans which expose the body to cumulative ionizing radiation and thus attendant cancer risks. The aim of this study was to determine whether using a combination of Automatic Tube Current Modulation (ATCM) and Automatic Tube Voltage Selection (ATVS) during two-phase whole-body CT (2PWBCT) examinations would reduce the radiation dose while preserving the image quality.</p><p><strong>Patients and methods: </strong>This was a prospective, observational, single-centre study of 127 adult patients who had undergone the 2PWBCT polytraumatic protocol. All were examined on a Somatom Drive scanner (Siemens). The patients were divided into two groups: ATCM only (42 patients) and ATCM +ATVS (85 patients). Patients' arm positions during examination and the examination dose length product (DLP) values were recorded, as well the standard deviations (SD) of the density in reference areas on CT scans for the image quality assessment. The DLP values and image quality in the groups were compared using ANOVA.</p><p><strong>Results: </strong>Mean Total DLP (in mGy*cm): ATCM only: 3337 +/-797, ATCM+ATVS: 3402 +/-830; P=0.674. No effect of arm position (P=0.586). Mean density SD values in reference areas (in HU) in ATCM only: 49 +/-45, 15 +/-6, 9 +/-2, 12 +/-4, 10 +/-3, in ATCM+ATVS: 48 +/-45, 17 +/-6, 11 +/-3, 15 +/-6, 12 +/-4. SD values was higher in ATCM+ATVS group (P<0.001).</p><p><strong>Conclusion: </strong>Combination of ATVS and ATCM in polytraumatic 2PWBCT leads to no significant radiation load reduction compared with ATCM only but does lead to a slight degradation of image quality. The radiation load is significantly reduced if the patient has their arms behind the head when scanning, regardless of the activation of ATVS.</p>\",\"PeriodicalId\":55363,\"journal\":{\"name\":\"Biomedical Papers-Olomouc\",\"volume\":\" \",\"pages\":\"304-310\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Papers-Olomouc\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5507/bp.2024.004\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/4 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Papers-Olomouc","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5507/bp.2024.004","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/4 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

背景和目的:目前,人造辐射的一个重要来源与医疗设备有关,特别是以 X 射线成像为基础的设备,如 CT 扫描,这些设备会使人体暴露于累积的电离辐射中,从而导致癌症风险。本研究旨在确定在两相全身 CT(2PWBCT)检查中结合使用自动管电流调制(ATCM)和自动管电压选择(ATVS)是否能在保持图像质量的同时减少辐射剂量:这是一项前瞻性、观察性、单中心研究,研究对象为 127 名接受过 2PWBCT 多创伤方案检查的成年患者。所有患者都在 Somatom Drive 扫描仪(西门子)上进行了检查。患者被分为两组:仅 ATCM 组(42 名患者)和 ATCM +ATVS 组(85 名患者)。患者在检查过程中的手臂位置和检查剂量长度乘积(DLP)值以及 CT 扫描参考区域密度的标准偏差(SD)都被记录下来,用于图像质量评估。采用方差分析比较了各组的 DLP 值和图像质量:总 DLP 平均值(单位:mGy*cm):仅 ATCM:3337 +/-797,ATCM+ATVS:3402 +/-830;P=0.674。手臂位置无影响(P=0.586)。仅 ATCM 组参考区域的平均密度 SD 值(以 HU 为单位):49 +/-45、15 +/-6、9 +/-2、12 +/-4、10 +/-3,ATCM+ATVS 组:48 +/-45、17 +/-6、11 +/-3、15 +/-6、12 +/-4,ATCM+ATVS 组的 SD 值更高:在多创伤 2PWBCT 中结合使用 ATVS 和 ATCM 与仅使用 ATCM 相比,辐射负荷没有明显降低,但图像质量略有下降。无论是否启动 ATVS,如果患者在扫描时将手臂放在头后,辐射负荷都会明显降低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of dose length product and image quality of a biphasic whole-body polytrauma CT protocol with and without the automatic tube voltage selection.

Background and aims: A significant source of man-made radiation is now linked to medical devices especially X-ray imaging based ones like CT scans which expose the body to cumulative ionizing radiation and thus attendant cancer risks. The aim of this study was to determine whether using a combination of Automatic Tube Current Modulation (ATCM) and Automatic Tube Voltage Selection (ATVS) during two-phase whole-body CT (2PWBCT) examinations would reduce the radiation dose while preserving the image quality.

Patients and methods: This was a prospective, observational, single-centre study of 127 adult patients who had undergone the 2PWBCT polytraumatic protocol. All were examined on a Somatom Drive scanner (Siemens). The patients were divided into two groups: ATCM only (42 patients) and ATCM +ATVS (85 patients). Patients' arm positions during examination and the examination dose length product (DLP) values were recorded, as well the standard deviations (SD) of the density in reference areas on CT scans for the image quality assessment. The DLP values and image quality in the groups were compared using ANOVA.

Results: Mean Total DLP (in mGy*cm): ATCM only: 3337 +/-797, ATCM+ATVS: 3402 +/-830; P=0.674. No effect of arm position (P=0.586). Mean density SD values in reference areas (in HU) in ATCM only: 49 +/-45, 15 +/-6, 9 +/-2, 12 +/-4, 10 +/-3, in ATCM+ATVS: 48 +/-45, 17 +/-6, 11 +/-3, 15 +/-6, 12 +/-4. SD values was higher in ATCM+ATVS group (P<0.001).

Conclusion: Combination of ATVS and ATCM in polytraumatic 2PWBCT leads to no significant radiation load reduction compared with ATCM only but does lead to a slight degradation of image quality. The radiation load is significantly reduced if the patient has their arms behind the head when scanning, regardless of the activation of ATVS.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biomedical Papers-Olomouc
Biomedical Papers-Olomouc MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
2.30
自引率
0.00%
发文量
74
审稿时长
6-12 weeks
期刊介绍: Biomedical Papers is a journal of Palacký University Olomouc, Faculty of Medicine and Dentistry, Olomouc, Czech Republic. It includes reviews and original articles reporting on basic and clinical research in medicine. Biomedical Papers is published as one volume per year in four issues.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信