Suriya Luenam, Arkaphat Kosiyatrakul, Chris Charoenlap, Chedtha Puncreobutr, Boonrat Lohwongwatana
{"title":"使用 3D 打印患者特异性钛假体置换桡骨头:一项多中心前瞻性研究的初步结果。","authors":"Suriya Luenam, Arkaphat Kosiyatrakul, Chris Charoenlap, Chedtha Puncreobutr, Boonrat Lohwongwatana","doi":"10.1177/10225536241236806","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To report preliminary clinical results and safety of 3D-printed patient-specific titanium radial head (RH) prosthesis in treatment of the irreparable RH fractures.</p><p><strong>Material and methods: </strong>This multi-centric prospective study included 10 patients (6 men and four women, mean age 41 years (range, 25-64 years)). Three cases were classified as Mason type III and 7 cases as type IV. Patients were assessed preoperatively, intraoperatively, and at 1, 6, 12, 24, 36, and 48 weeks postoperatively. Range of motion (ROM), visual analog scale (VAS) score, Disabilities of the Arm, Shoulder and Hand (DASH) score, Mayo Elbow Performance Score (MEPS), radiology imaging, and laboratory blood and urine testing were evaluated.</p><p><strong>Results: </strong>The prostheses were implanted utilizing cemented stems in 5 patients and cementless stems in 5 patients. Intraoperatively, well congruency of a prosthesis with capitellum and radial notch of ulna was observed in all cases. All patients had improvement of ROM, VAS score, DASH score, and MEPS during the postoperative follow-ups. At the final follow-up, mean elbow extension was 6.5° (range, 0°-30°), flexion 145° (range, 125°-150°), supination 79° (range, 70°-80°), and pronation 73.5° (range, 45°-80°). Mean VAS score was 0.3 (range, 0-3), DASH score was 12.35 (range, 1.7-23.3), and MEPS was 99.5 (range, 95-100). Postoperative radiographs demonstrated heterotopic ossification in 2 cases, periprosthetic radiolucency in 2 cases, and proximal radial neck resorption in 2 cases. No one had the evidence of capitellar erosion, implant failure, malpositioning, overstuffing, or symptomatic stem loosening. There was no significant alteration of laboratory results or adverse events related to the 3D-printed prosthesis implantation.</p><p><strong>Conclusion: </strong>The preliminary results demonstrated that implantation of the 3D-printed patient-specific titanium RH prosthesis is safe and may be a potential treatment option for irreparable RH fracture.</p>","PeriodicalId":16608,"journal":{"name":"Journal of Orthopaedic Surgery","volume":"32 1","pages":"10225536241236806"},"PeriodicalIF":1.6000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Radial head replacement with the 3D-printed patient-specific titanium prosthesis: Preliminary results of a multi-centric prospective study.\",\"authors\":\"Suriya Luenam, Arkaphat Kosiyatrakul, Chris Charoenlap, Chedtha Puncreobutr, Boonrat Lohwongwatana\",\"doi\":\"10.1177/10225536241236806\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To report preliminary clinical results and safety of 3D-printed patient-specific titanium radial head (RH) prosthesis in treatment of the irreparable RH fractures.</p><p><strong>Material and methods: </strong>This multi-centric prospective study included 10 patients (6 men and four women, mean age 41 years (range, 25-64 years)). Three cases were classified as Mason type III and 7 cases as type IV. Patients were assessed preoperatively, intraoperatively, and at 1, 6, 12, 24, 36, and 48 weeks postoperatively. Range of motion (ROM), visual analog scale (VAS) score, Disabilities of the Arm, Shoulder and Hand (DASH) score, Mayo Elbow Performance Score (MEPS), radiology imaging, and laboratory blood and urine testing were evaluated.</p><p><strong>Results: </strong>The prostheses were implanted utilizing cemented stems in 5 patients and cementless stems in 5 patients. Intraoperatively, well congruency of a prosthesis with capitellum and radial notch of ulna was observed in all cases. All patients had improvement of ROM, VAS score, DASH score, and MEPS during the postoperative follow-ups. At the final follow-up, mean elbow extension was 6.5° (range, 0°-30°), flexion 145° (range, 125°-150°), supination 79° (range, 70°-80°), and pronation 73.5° (range, 45°-80°). Mean VAS score was 0.3 (range, 0-3), DASH score was 12.35 (range, 1.7-23.3), and MEPS was 99.5 (range, 95-100). Postoperative radiographs demonstrated heterotopic ossification in 2 cases, periprosthetic radiolucency in 2 cases, and proximal radial neck resorption in 2 cases. No one had the evidence of capitellar erosion, implant failure, malpositioning, overstuffing, or symptomatic stem loosening. There was no significant alteration of laboratory results or adverse events related to the 3D-printed prosthesis implantation.</p><p><strong>Conclusion: </strong>The preliminary results demonstrated that implantation of the 3D-printed patient-specific titanium RH prosthesis is safe and may be a potential treatment option for irreparable RH fracture.</p>\",\"PeriodicalId\":16608,\"journal\":{\"name\":\"Journal of Orthopaedic Surgery\",\"volume\":\"32 1\",\"pages\":\"10225536241236806\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orthopaedic Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/10225536241236806\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/10225536241236806","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
目的:报告3D打印患者特异性钛合金桡骨头(RH)假体治疗不可修复的RH骨折的初步临床结果和安全性:这项多中心前瞻性研究共纳入 10 例患者(6 男 4 女,平均年龄 41 岁(25-64 岁))。其中 3 例为梅森 III 型,7 例为 IV 型。对患者进行了术前、术中和术后 1、6、12、24、36 和 48 周的评估。对患者的活动范围(ROM)、视觉模拟量表(VAS)评分、手臂、肩部和手部残疾(DASH)评分、梅奥肘关节功能评分(MEPS)、放射成像以及实验室血液和尿液检测进行了评估:5名患者使用骨水泥柄植入假体,5名患者使用无骨水泥柄植入假体。术中观察到,所有病例的假体都与髌骨和尺骨桡侧切迹完全吻合。术后随访期间,所有患者的活动度、VAS评分、DASH评分和MEPS均有改善。最后随访时,平均肘关节伸展6.5°(范围0°-30°),屈曲145°(范围125°-150°),上举79°(范围70°-80°),前伸73.5°(范围45°-80°)。平均 VAS 评分为 0.3(范围为 0-3),DASH 评分为 12.35(范围为 1.7-23.3),MEPS 为 99.5(范围为 95-100)。术后X光片显示,2例出现异位骨化,2例出现假体周围桡骨骨质增生,2例出现桡骨近端颈部吸收。没有人出现帽状侵蚀、植入失败、定位不当、过度充填或症状性茎突松动。与3D打印假体植入相关的实验室结果或不良事件均无明显变化:初步结果表明,植入3D打印的患者特异性钛合金RH假体是安全的,可能是治疗不可修复的RH骨折的一种潜在方法。
Radial head replacement with the 3D-printed patient-specific titanium prosthesis: Preliminary results of a multi-centric prospective study.
Purpose: To report preliminary clinical results and safety of 3D-printed patient-specific titanium radial head (RH) prosthesis in treatment of the irreparable RH fractures.
Material and methods: This multi-centric prospective study included 10 patients (6 men and four women, mean age 41 years (range, 25-64 years)). Three cases were classified as Mason type III and 7 cases as type IV. Patients were assessed preoperatively, intraoperatively, and at 1, 6, 12, 24, 36, and 48 weeks postoperatively. Range of motion (ROM), visual analog scale (VAS) score, Disabilities of the Arm, Shoulder and Hand (DASH) score, Mayo Elbow Performance Score (MEPS), radiology imaging, and laboratory blood and urine testing were evaluated.
Results: The prostheses were implanted utilizing cemented stems in 5 patients and cementless stems in 5 patients. Intraoperatively, well congruency of a prosthesis with capitellum and radial notch of ulna was observed in all cases. All patients had improvement of ROM, VAS score, DASH score, and MEPS during the postoperative follow-ups. At the final follow-up, mean elbow extension was 6.5° (range, 0°-30°), flexion 145° (range, 125°-150°), supination 79° (range, 70°-80°), and pronation 73.5° (range, 45°-80°). Mean VAS score was 0.3 (range, 0-3), DASH score was 12.35 (range, 1.7-23.3), and MEPS was 99.5 (range, 95-100). Postoperative radiographs demonstrated heterotopic ossification in 2 cases, periprosthetic radiolucency in 2 cases, and proximal radial neck resorption in 2 cases. No one had the evidence of capitellar erosion, implant failure, malpositioning, overstuffing, or symptomatic stem loosening. There was no significant alteration of laboratory results or adverse events related to the 3D-printed prosthesis implantation.
Conclusion: The preliminary results demonstrated that implantation of the 3D-printed patient-specific titanium RH prosthesis is safe and may be a potential treatment option for irreparable RH fracture.
期刊介绍:
Journal of Orthopaedic Surgery is an open access peer-reviewed journal publishing original reviews and research articles on all aspects of orthopaedic surgery. It is the official journal of the Asia Pacific Orthopaedic Association.
The journal welcomes and will publish materials of a diverse nature, from basic science research to clinical trials and surgical techniques. The journal encourages contributions from all parts of the world, but special emphasis is given to research of particular relevance to the Asia Pacific region.