经皮椎弓根螺钉置入治疗胸腰交界处创伤性骨折的三维导航和透视引导比较

IF 1.9 Q3 CLINICAL NEUROLOGY
Fenna Brunken , Eric Mandelka , Benno Bullert , Paul Alfred Gruetzner , Sven Y. Vetter , Jula Gierse
{"title":"经皮椎弓根螺钉置入治疗胸腰交界处创伤性骨折的三维导航和透视引导比较","authors":"Fenna Brunken ,&nbsp;Eric Mandelka ,&nbsp;Benno Bullert ,&nbsp;Paul Alfred Gruetzner ,&nbsp;Sven Y. Vetter ,&nbsp;Jula Gierse","doi":"10.1016/j.bas.2024.102769","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Fractures of the thoracolumbar junction are the most common vertebral fractures and can require surgical treatment. Several studies have shown that the accuracy of pedicle screw placement can be improved by the use of 3D-navigation. Still only few studies have focused on the use of navigation in traumatic spine injuries.</p></div><div><h3>Research question</h3><p>The aim of this study was to compare the screw placement accuracy and radiation exposure for 3D-navigated and fluoroscopy-guided percutaneous pedicle screw placement in traumatic fractures of the thoracolumbar junction.</p></div><div><h3>Materials and methods</h3><p>In this single-center study 25 patients undergoing 3D-navigated percutaneous pedicle screw placement for traumatic fractures of the thoracolumbar junction (T12-L2) were compared to a control group of 25 patients using fluoroscopy. Screw accuracy was determined in postoperative CT-scans using the Gertzbein-Robbins classification system. Additionally, duration of surgery, dose area product, fluoroscopy time and intraoperative complications were compared between the groups.</p></div><div><h3>Results</h3><p>The accuracy of 3D-navigated percutaneous pedicle screw placement was 92.66 % while an accuracy of 88.08 % was achieved using standard fluoroscopy (p = 0.19). The fluoroscopy time was significantly less in the navigation group compared to the control group (p = 0.0002). There were no significant differences in radiation exposure, duration of surgery or intraoperative complications between the groups.</p></div><div><h3>Discussion and conclusion</h3><p>The results suggest that 3D-navigation facilitates higher accuracy in percutaneous pedicle screw placement of traumatic fractures of the thoracolumbar junction, although limitations should be considered. In this study 3D-navigation did not increase fluoroscopy time, while radiation exposure and surgery time were comparable.</p></div>","PeriodicalId":72443,"journal":{"name":"Brain & spine","volume":"4 ","pages":"Article 102769"},"PeriodicalIF":1.9000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2772529424000250/pdfft?md5=9cb50edf7abacbc087614e54433a7e49&pid=1-s2.0-S2772529424000250-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Comparison of 3D-navigation and fluoroscopic guidance in percutaneous pedicle screw placement for traumatic fractures of the thoracolumbar junction\",\"authors\":\"Fenna Brunken ,&nbsp;Eric Mandelka ,&nbsp;Benno Bullert ,&nbsp;Paul Alfred Gruetzner ,&nbsp;Sven Y. Vetter ,&nbsp;Jula Gierse\",\"doi\":\"10.1016/j.bas.2024.102769\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><p>Fractures of the thoracolumbar junction are the most common vertebral fractures and can require surgical treatment. Several studies have shown that the accuracy of pedicle screw placement can be improved by the use of 3D-navigation. Still only few studies have focused on the use of navigation in traumatic spine injuries.</p></div><div><h3>Research question</h3><p>The aim of this study was to compare the screw placement accuracy and radiation exposure for 3D-navigated and fluoroscopy-guided percutaneous pedicle screw placement in traumatic fractures of the thoracolumbar junction.</p></div><div><h3>Materials and methods</h3><p>In this single-center study 25 patients undergoing 3D-navigated percutaneous pedicle screw placement for traumatic fractures of the thoracolumbar junction (T12-L2) were compared to a control group of 25 patients using fluoroscopy. Screw accuracy was determined in postoperative CT-scans using the Gertzbein-Robbins classification system. Additionally, duration of surgery, dose area product, fluoroscopy time and intraoperative complications were compared between the groups.</p></div><div><h3>Results</h3><p>The accuracy of 3D-navigated percutaneous pedicle screw placement was 92.66 % while an accuracy of 88.08 % was achieved using standard fluoroscopy (p = 0.19). The fluoroscopy time was significantly less in the navigation group compared to the control group (p = 0.0002). There were no significant differences in radiation exposure, duration of surgery or intraoperative complications between the groups.</p></div><div><h3>Discussion and conclusion</h3><p>The results suggest that 3D-navigation facilitates higher accuracy in percutaneous pedicle screw placement of traumatic fractures of the thoracolumbar junction, although limitations should be considered. In this study 3D-navigation did not increase fluoroscopy time, while radiation exposure and surgery time were comparable.</p></div>\",\"PeriodicalId\":72443,\"journal\":{\"name\":\"Brain & spine\",\"volume\":\"4 \",\"pages\":\"Article 102769\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2772529424000250/pdfft?md5=9cb50edf7abacbc087614e54433a7e49&pid=1-s2.0-S2772529424000250-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Brain & spine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2772529424000250\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brain & spine","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772529424000250","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

导言胸腰椎交界处骨折是最常见的脊椎骨折,可能需要手术治疗。多项研究表明,使用三维导航可以提高椎弓根螺钉置放的准确性。本研究旨在比较三维导航和透视引导下经皮椎弓根螺钉置入治疗胸腰交界处创伤性骨折的螺钉置入准确性和辐射暴露。材料和方法在这项单中心研究中,25 名接受三维导航经皮椎弓根螺钉置入术治疗胸腰交界处(T12-L2)创伤性骨折的患者与 25 名使用透视法的对照组患者进行了比较。术后 CT 扫描采用 Gertzbein-Robbins 分类系统确定螺钉的准确性。结果三维导航经皮椎弓根螺钉置入的准确率为 92.66%,而标准透视的准确率为 88.08%(P = 0.19)。导航组的透视时间明显少于对照组(p = 0.0002)。讨论与结论结果表明,三维导航有助于提高胸腰椎交界处创伤性骨折经皮椎弓根螺钉置入术的准确性,但也应考虑到其局限性。在这项研究中,三维导航没有增加透视时间,而辐射暴露和手术时间相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of 3D-navigation and fluoroscopic guidance in percutaneous pedicle screw placement for traumatic fractures of the thoracolumbar junction

Introduction

Fractures of the thoracolumbar junction are the most common vertebral fractures and can require surgical treatment. Several studies have shown that the accuracy of pedicle screw placement can be improved by the use of 3D-navigation. Still only few studies have focused on the use of navigation in traumatic spine injuries.

Research question

The aim of this study was to compare the screw placement accuracy and radiation exposure for 3D-navigated and fluoroscopy-guided percutaneous pedicle screw placement in traumatic fractures of the thoracolumbar junction.

Materials and methods

In this single-center study 25 patients undergoing 3D-navigated percutaneous pedicle screw placement for traumatic fractures of the thoracolumbar junction (T12-L2) were compared to a control group of 25 patients using fluoroscopy. Screw accuracy was determined in postoperative CT-scans using the Gertzbein-Robbins classification system. Additionally, duration of surgery, dose area product, fluoroscopy time and intraoperative complications were compared between the groups.

Results

The accuracy of 3D-navigated percutaneous pedicle screw placement was 92.66 % while an accuracy of 88.08 % was achieved using standard fluoroscopy (p = 0.19). The fluoroscopy time was significantly less in the navigation group compared to the control group (p = 0.0002). There were no significant differences in radiation exposure, duration of surgery or intraoperative complications between the groups.

Discussion and conclusion

The results suggest that 3D-navigation facilitates higher accuracy in percutaneous pedicle screw placement of traumatic fractures of the thoracolumbar junction, although limitations should be considered. In this study 3D-navigation did not increase fluoroscopy time, while radiation exposure and surgery time were comparable.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Brain & spine
Brain & spine Surgery
CiteScore
1.10
自引率
0.00%
发文量
0
审稿时长
71 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信