评估视网膜色素变性的全视野刺激阈值测试结果:与全视野视网膜电图、多焦点视网膜电图、光学相干断层扫描和视野的关系。

Q3 Medicine
Ayşe Öner, Neslihan Sinim Kahraman
{"title":"评估视网膜色素变性的全视野刺激阈值测试结果:与全视野视网膜电图、多焦点视网膜电图、光学相干断层扫描和视野的关系。","authors":"Ayşe Öner, Neslihan Sinim Kahraman","doi":"10.4274/tjo.galenos.2023.58485","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The full-field stimulus threshold (FST) test was developed to evaluate the efficacy and safety of treatments of hereditary retinal diseases. In this study we performed the FST test in patients with retinitis pigmentosa (RP) and compared the results with findings from other ophthalmological tests.</p><p><strong>Materials and methods: </strong>The study included 51 intermediate and advanced RP patients and 21 normal subjects. All patients and controls underwent routine examination and ophthalmological tests including visual field, optical coherence tomography, full-field and multifocal electroretinography (mfERG), and FST tests. During FST testing, the perception thresholds of retina to the white, blue, and red FST were determined in decibels.</p><p><strong>Results: </strong>The mean age of the patients and the controls were 35.2 and 33.5 years, respectively. For all RP patients, no response was obtained on full-field ERG. All subjects were able to perform reliable FST tests. The mean values of visual acuity and central macular thickness were significantly lower and visual field mean deviation values were significantly higher in the RP group than the controls. When we evaluated the mfERG findings, the mean P1 wave amplitudes in all rings were significantly lower and the mean peak times were significantly longer in RP patients than controls. In comparisons of FST test results, the mean values for white, blue, red and the difference between blue-red thresholds were significantly lower in the RP group than the control group.</p><p><strong>Conclusion: </strong>The FST test is a fast and a reliable exam which can be done in subjects with poor visual acuity and reduced visual field. The results of this study confirm that the FST test can measure retinal sensitivity in severely affected RP subjects with flat flash ERG.</p>","PeriodicalId":23373,"journal":{"name":"Turkish Journal of Ophthalmology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-02-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10895166/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Full-Field Stimulus Threshold Test Results in Retinitis Pigmentosa: Relationship with Full-Field Electroretinography, Multifocal Electroretinography, Optical Coherence Tomography, and Visual Field.\",\"authors\":\"Ayşe Öner, Neslihan Sinim Kahraman\",\"doi\":\"10.4274/tjo.galenos.2023.58485\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The full-field stimulus threshold (FST) test was developed to evaluate the efficacy and safety of treatments of hereditary retinal diseases. In this study we performed the FST test in patients with retinitis pigmentosa (RP) and compared the results with findings from other ophthalmological tests.</p><p><strong>Materials and methods: </strong>The study included 51 intermediate and advanced RP patients and 21 normal subjects. All patients and controls underwent routine examination and ophthalmological tests including visual field, optical coherence tomography, full-field and multifocal electroretinography (mfERG), and FST tests. During FST testing, the perception thresholds of retina to the white, blue, and red FST were determined in decibels.</p><p><strong>Results: </strong>The mean age of the patients and the controls were 35.2 and 33.5 years, respectively. For all RP patients, no response was obtained on full-field ERG. All subjects were able to perform reliable FST tests. The mean values of visual acuity and central macular thickness were significantly lower and visual field mean deviation values were significantly higher in the RP group than the controls. When we evaluated the mfERG findings, the mean P1 wave amplitudes in all rings were significantly lower and the mean peak times were significantly longer in RP patients than controls. In comparisons of FST test results, the mean values for white, blue, red and the difference between blue-red thresholds were significantly lower in the RP group than the control group.</p><p><strong>Conclusion: </strong>The FST test is a fast and a reliable exam which can be done in subjects with poor visual acuity and reduced visual field. The results of this study confirm that the FST test can measure retinal sensitivity in severely affected RP subjects with flat flash ERG.</p>\",\"PeriodicalId\":23373,\"journal\":{\"name\":\"Turkish Journal of Ophthalmology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10895166/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Turkish Journal of Ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4274/tjo.galenos.2023.58485\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4274/tjo.galenos.2023.58485","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:开发全视野刺激阈(FST)测试是为了评估遗传性视网膜疾病治疗的有效性和安全性。在这项研究中,我们对视网膜色素变性(RP)患者进行了 FST 测试,并将测试结果与其他眼科测试结果进行了比较:研究对象包括 51 名中晚期视网膜色素变性患者和 21 名正常人。所有患者和对照组均接受了常规检查和眼科测试,包括视野、光学相干断层扫描、全视野和多焦视网膜电图(mfERG)以及 FST 测试。在 FST 测试中,以分贝为单位测定视网膜对白色、蓝色和红色 FST 的感知阈值:患者和对照组的平均年龄分别为 35.2 岁和 33.5 岁。所有红斑狼疮患者在全视野 ERG 上都没有反应。所有受试者都能进行可靠的 FST 测试。与对照组相比,RP 组患者的视力和黄斑中心厚度平均值明显较低,视野平均偏差值明显较高。在评估 mfERG 结果时,RP 患者所有环的平均 P1 波振幅明显低于对照组,平均峰值时间明显长于对照组。在比较 FST 测试结果时,RP 组患者的白、蓝、红平均值以及蓝红阈值之差均明显低于对照组:FST测试是一种快速、可靠的检查方法,适用于视力较差和视野缩小的受试者。本研究的结果证实,FST 测试可以测量受严重影响的 RP 受试者的视网膜敏感度,而这些受试者的闪光 ERG 是扁平的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of Full-Field Stimulus Threshold Test Results in Retinitis Pigmentosa: Relationship with Full-Field Electroretinography, Multifocal Electroretinography, Optical Coherence Tomography, and Visual Field.

Objectives: The full-field stimulus threshold (FST) test was developed to evaluate the efficacy and safety of treatments of hereditary retinal diseases. In this study we performed the FST test in patients with retinitis pigmentosa (RP) and compared the results with findings from other ophthalmological tests.

Materials and methods: The study included 51 intermediate and advanced RP patients and 21 normal subjects. All patients and controls underwent routine examination and ophthalmological tests including visual field, optical coherence tomography, full-field and multifocal electroretinography (mfERG), and FST tests. During FST testing, the perception thresholds of retina to the white, blue, and red FST were determined in decibels.

Results: The mean age of the patients and the controls were 35.2 and 33.5 years, respectively. For all RP patients, no response was obtained on full-field ERG. All subjects were able to perform reliable FST tests. The mean values of visual acuity and central macular thickness were significantly lower and visual field mean deviation values were significantly higher in the RP group than the controls. When we evaluated the mfERG findings, the mean P1 wave amplitudes in all rings were significantly lower and the mean peak times were significantly longer in RP patients than controls. In comparisons of FST test results, the mean values for white, blue, red and the difference between blue-red thresholds were significantly lower in the RP group than the control group.

Conclusion: The FST test is a fast and a reliable exam which can be done in subjects with poor visual acuity and reduced visual field. The results of this study confirm that the FST test can measure retinal sensitivity in severely affected RP subjects with flat flash ERG.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Turkish Journal of Ophthalmology
Turkish Journal of Ophthalmology Medicine-Ophthalmology
CiteScore
2.20
自引率
0.00%
发文量
0
期刊介绍: The Turkish Journal of Ophthalmology (TJO) is the only scientific periodical publication of the Turkish Ophthalmological Association and has been published since January 1929. In its early years, the journal was published in Turkish and French. Although there were temporary interruptions in the publication of the journal due to various challenges, the Turkish Journal of Ophthalmology has been published continually from 1971 to the present. The target audience includes specialists and physicians in training in ophthalmology in all relevant disciplines.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信