全髋关节置换术中保证神经安全的最佳牵引器插入点:股神经和坐骨神经与髋关节运动关系的解剖学研究。

IF 1.3 4区 医学 Q3 ORTHOPEDICS
HIP International Pub Date : 2024-07-01 Epub Date: 2024-02-19 DOI:10.1177/11207000241227399
Masakazu Okamoto, Yoshinobu Uchihara, Kenichiro Saito, Yusuke Inagaki, Pasuk Mahakkanukrauh, Yasuhito Tanaka
{"title":"全髋关节置换术中保证神经安全的最佳牵引器插入点:股神经和坐骨神经与髋关节运动关系的解剖学研究。","authors":"Masakazu Okamoto, Yoshinobu Uchihara, Kenichiro Saito, Yusuke Inagaki, Pasuk Mahakkanukrauh, Yasuhito Tanaka","doi":"10.1177/11207000241227399","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Nerve injury is one of the most serious complications of total hip arthroplasty (THA). It is suspected to be a result from nerve compression or direct injury caused by an acetabular retractor. The anatomical relationship between the acetabular rim and the femoral and sciatic nerves, including hip motion, has not been investigated. This study aimed to identify the optimal position for retractor insertion during THA to prevent nerve damage.</p><p><strong>Methods: </strong>A total of 28 hip joints from 14 freshly frozen cadavers were used. Using an anterolateral approach, each cadaver was immobilised in the lateral decubitus position and deployed to measure the distance between the nerves and the acetabular rim, while the hip joint was changed to the extension, neutral, and flexion positions.</p><p><strong>Results: </strong>Three femoral nerves were closest to the anterior margin of the acetabulum at 90° and 120° of extension and farthest away at 30° of flexion. The sciatic nerve was closest to the posterior margin of the acetabulum at 90° and 120° of flexion and farthest away at 30° and 150° of extension compared with the other points.</p><p><strong>Conclusions: </strong>To prevent nerve damage during THA, we suggest that the retractor be inserted at the points where the nerves are the farthest away, such as at 30° and 150°. The femoral and sciatic nerves vary in their movements depending on the hip position. Therefore, the safe insertion of a retractor is recommended for hip flexion of the femoral nerve and extension of the sciatic nerve. Additionally, it is important to carefully insert the retractor along the acetabular margin without penetrating the joint capsule. Overall, this study provides valuable insights into the anatomical location and movement of the femoral and sciatic nerves in relation to hip motion and can help inform surgical techniques for safer THA.</p>","PeriodicalId":12911,"journal":{"name":"HIP International","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimal retractor insertion point for nerve safety during total hip arthroplasty: an anatomical study on the femoral and sciatic nerves in relation to hip motion.\",\"authors\":\"Masakazu Okamoto, Yoshinobu Uchihara, Kenichiro Saito, Yusuke Inagaki, Pasuk Mahakkanukrauh, Yasuhito Tanaka\",\"doi\":\"10.1177/11207000241227399\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Nerve injury is one of the most serious complications of total hip arthroplasty (THA). It is suspected to be a result from nerve compression or direct injury caused by an acetabular retractor. The anatomical relationship between the acetabular rim and the femoral and sciatic nerves, including hip motion, has not been investigated. This study aimed to identify the optimal position for retractor insertion during THA to prevent nerve damage.</p><p><strong>Methods: </strong>A total of 28 hip joints from 14 freshly frozen cadavers were used. Using an anterolateral approach, each cadaver was immobilised in the lateral decubitus position and deployed to measure the distance between the nerves and the acetabular rim, while the hip joint was changed to the extension, neutral, and flexion positions.</p><p><strong>Results: </strong>Three femoral nerves were closest to the anterior margin of the acetabulum at 90° and 120° of extension and farthest away at 30° of flexion. The sciatic nerve was closest to the posterior margin of the acetabulum at 90° and 120° of flexion and farthest away at 30° and 150° of extension compared with the other points.</p><p><strong>Conclusions: </strong>To prevent nerve damage during THA, we suggest that the retractor be inserted at the points where the nerves are the farthest away, such as at 30° and 150°. The femoral and sciatic nerves vary in their movements depending on the hip position. Therefore, the safe insertion of a retractor is recommended for hip flexion of the femoral nerve and extension of the sciatic nerve. Additionally, it is important to carefully insert the retractor along the acetabular margin without penetrating the joint capsule. Overall, this study provides valuable insights into the anatomical location and movement of the femoral and sciatic nerves in relation to hip motion and can help inform surgical techniques for safer THA.</p>\",\"PeriodicalId\":12911,\"journal\":{\"name\":\"HIP International\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"HIP International\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/11207000241227399\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/19 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"HIP International","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11207000241227399","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/19 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

背景:神经损伤是全髋关节置换术(THA)最严重的并发症之一:神经损伤是全髋关节置换术(THA)最严重的并发症之一。它被怀疑是神经受压或髋臼牵引器直接损伤所致。髋臼边缘与股神经和坐骨神经之间的解剖关系,包括髋关节的运动,尚未得到研究。本研究旨在确定在全髋关节置换术中插入牵引器的最佳位置,以防止神经损伤:方法:共使用了来自 14 具新鲜冷冻尸体的 28 个髋关节。采用前外侧入路,将每具尸体固定在侧卧位,并在髋关节变为伸直、中立和屈曲位时展开,测量神经与髋臼边缘之间的距离:结果:在伸展90°和120°时,三条股神经最靠近髋臼前缘,而在屈曲30°时距离最远。与其他点相比,坐骨神经在屈曲 90°和 120°时最靠近髋臼后缘,在伸展 30°和 150°时最远离髋臼后缘:为防止在 THA 期间损伤神经,我们建议将牵开器插入神经距离最远的点,如 30° 和 150°。股神经和坐骨神经的运动因髋关节位置而异。因此,建议在股神经屈髋和坐骨神经伸展时安全插入牵开器。此外,沿着髋臼边缘小心插入牵开器而不穿透关节囊也很重要。总之,该研究为了解股神经和坐骨神经的解剖位置和运动与髋关节运动的关系提供了宝贵的见解,有助于为更安全的 THA 提供手术技术信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimal retractor insertion point for nerve safety during total hip arthroplasty: an anatomical study on the femoral and sciatic nerves in relation to hip motion.

Background: Nerve injury is one of the most serious complications of total hip arthroplasty (THA). It is suspected to be a result from nerve compression or direct injury caused by an acetabular retractor. The anatomical relationship between the acetabular rim and the femoral and sciatic nerves, including hip motion, has not been investigated. This study aimed to identify the optimal position for retractor insertion during THA to prevent nerve damage.

Methods: A total of 28 hip joints from 14 freshly frozen cadavers were used. Using an anterolateral approach, each cadaver was immobilised in the lateral decubitus position and deployed to measure the distance between the nerves and the acetabular rim, while the hip joint was changed to the extension, neutral, and flexion positions.

Results: Three femoral nerves were closest to the anterior margin of the acetabulum at 90° and 120° of extension and farthest away at 30° of flexion. The sciatic nerve was closest to the posterior margin of the acetabulum at 90° and 120° of flexion and farthest away at 30° and 150° of extension compared with the other points.

Conclusions: To prevent nerve damage during THA, we suggest that the retractor be inserted at the points where the nerves are the farthest away, such as at 30° and 150°. The femoral and sciatic nerves vary in their movements depending on the hip position. Therefore, the safe insertion of a retractor is recommended for hip flexion of the femoral nerve and extension of the sciatic nerve. Additionally, it is important to carefully insert the retractor along the acetabular margin without penetrating the joint capsule. Overall, this study provides valuable insights into the anatomical location and movement of the femoral and sciatic nerves in relation to hip motion and can help inform surgical techniques for safer THA.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
HIP International
HIP International 医学-整形外科
CiteScore
4.20
自引率
0.00%
发文量
70
审稿时长
2 months
期刊介绍: HIP International is the official journal of the European Hip Society. It is the only international, peer-reviewed, bi-monthly journal dedicated to diseases of the hip. HIP International considers contributions relating to hip surgery, traumatology of the hip, prosthetic surgery, biomechanics, and basic sciences relating to the hip. HIP International invites reviews from leading specialists with the aim of informing its readers of current evidence-based best practice. The journal also publishes supplements containing proceedings of symposia, special meetings or articles of special educational merit. HIP International is divided into six independent sections led by editors of the highest scientific merit. These sections are: • Biomaterials • Biomechanics • Conservative Hip Surgery • Paediatrics • Primary and Revision Hip Arthroplasty • Traumatology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信