{"title":"结扎线与弹性模块之间摩擦阻力的差异\"(体外研究)","authors":"Ahmad Khasara, Maen Dawodi, Arlyn Leslie Donesa","doi":"10.36571/ajsp643","DOIUrl":null,"url":null,"abstract":"Introduction: The purpose of this in-vitro study was to compare the frictional resistance forces generated by slid low friction elastomeric ligatures and stainless steel ligatures wire during leveling and alignment phase. Methods: The testing metal plates consisted of three stainless steel 0.022-in slot size preadjusted brackets of lateral incisor, canine and first premolar. First comparison were the bracket position vertically adhered to the plates. The second one were the canine bracket was adhered as a high canine in 2 mm. The forces generated by wires (0.014-in superelastic nickel-titanium) with the 2 types of ligatures at different bracket position were recorded. Results and Conclusions: The results of the present study revealed that there was a statistically significant difference in the frictional force between group A and group B with a p-value of 0.047 which is less than 0.05 level of significance, while there was no statistically significant difference in the frictional force between group C and group D with a p-value of 0.56 which is greater than 0.05 level of significance.","PeriodicalId":505380,"journal":{"name":"Arab Journal for Scientific Publishing","volume":"30 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"DIFFERENCE IN FRICTIONAL RESISTANCE BETWEEN LIGATURE WIRE AND ELASTIC MODULE” (AN IN VITRO STUDY)\",\"authors\":\"Ahmad Khasara, Maen Dawodi, Arlyn Leslie Donesa\",\"doi\":\"10.36571/ajsp643\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: The purpose of this in-vitro study was to compare the frictional resistance forces generated by slid low friction elastomeric ligatures and stainless steel ligatures wire during leveling and alignment phase. Methods: The testing metal plates consisted of three stainless steel 0.022-in slot size preadjusted brackets of lateral incisor, canine and first premolar. First comparison were the bracket position vertically adhered to the plates. The second one were the canine bracket was adhered as a high canine in 2 mm. The forces generated by wires (0.014-in superelastic nickel-titanium) with the 2 types of ligatures at different bracket position were recorded. Results and Conclusions: The results of the present study revealed that there was a statistically significant difference in the frictional force between group A and group B with a p-value of 0.047 which is less than 0.05 level of significance, while there was no statistically significant difference in the frictional force between group C and group D with a p-value of 0.56 which is greater than 0.05 level of significance.\",\"PeriodicalId\":505380,\"journal\":{\"name\":\"Arab Journal for Scientific Publishing\",\"volume\":\"30 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Arab Journal for Scientific Publishing\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.36571/ajsp643\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arab Journal for Scientific Publishing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36571/ajsp643","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
简介这项体外研究的目的是比较滑动低摩擦弹性结扎线和不锈钢结扎线在整平和对齐阶段产生的摩擦阻力。方法:测试金属板包括三个0.022英寸的不锈钢预调托槽,分别用于侧切牙、犬齿和第一前磨牙。首先比较的是托槽垂直粘附在金属板上的位置。第二个比较是将犬齿托槽作为高犬齿粘贴在 2 毫米处。记录了在不同托槽位置使用两种结扎方式的钢丝(0.014 英寸超弹性镍钛)所产生的力。结果和结论:本研究结果显示,A 组和 B 组之间的摩擦力存在显著差异,P 值为 0.047,小于 0.05 的显著性水平;而 C 组和 D 组之间的摩擦力没有显著差异,P 值为 0.56,大于 0.05 的显著性水平。
DIFFERENCE IN FRICTIONAL RESISTANCE BETWEEN LIGATURE WIRE AND ELASTIC MODULE” (AN IN VITRO STUDY)
Introduction: The purpose of this in-vitro study was to compare the frictional resistance forces generated by slid low friction elastomeric ligatures and stainless steel ligatures wire during leveling and alignment phase. Methods: The testing metal plates consisted of three stainless steel 0.022-in slot size preadjusted brackets of lateral incisor, canine and first premolar. First comparison were the bracket position vertically adhered to the plates. The second one were the canine bracket was adhered as a high canine in 2 mm. The forces generated by wires (0.014-in superelastic nickel-titanium) with the 2 types of ligatures at different bracket position were recorded. Results and Conclusions: The results of the present study revealed that there was a statistically significant difference in the frictional force between group A and group B with a p-value of 0.047 which is less than 0.05 level of significance, while there was no statistically significant difference in the frictional force between group C and group D with a p-value of 0.56 which is greater than 0.05 level of significance.