艾哈迈德瓣膜植入术后眼部生物测量的变化

IF 0.1 Q4 OPHTHALMOLOGY
Yunseog Choi, Kyong Jin Cho, Yuli Park
{"title":"艾哈迈德瓣膜植入术后眼部生物测量的变化","authors":"Yunseog Choi, Kyong Jin Cho, Yuli Park","doi":"10.3341/jkos.2024.65.2.132","DOIUrl":null,"url":null,"abstract":"Purpose: We assessed changes in ocular biometrics following Ahmed valve implantation.Methods: We conducted a retrospective analysis involving 76 eyes of 76 glaucoma patients who underwent Ahmed valve implantation; these patients were followed up for 6 months. Preoperative data, including age, intraocular pressure (IOP), refractive status, axial length, central corneal thickness, anterior chamber depth (ACD), anterior chamber volume (ACV), and anterior and posterior keratometry, were evaluated preoperatively and at 1 week, 1 month, and 6 months postoperatively.Results: The mean IOP exhibited a significant reduction from 39.17 ± 14.06 mmHg preoperatively to 11.43 ± 3.25 mmHg (p < 0.001), 13.18 ± 4.64 mmHg (p < 0.001), and 12.95 ± 4.37 mmHg (p < 0.001) at 1 week, 1 month, and 6 months postoperatively, respectively. Furthermore, the axial length exhibited a significant post-surgery reduction, measuring 23.74 ± 2.01 mm preoperatively and 23.48 ± 1.86 mm (p < 0.001), 23.57 ± 1.94 mm (p < 0.001), and 23.61 ± 1.98 mm (p = 0.002) at 1 week, 1 month, and 6 months postoperatively, respectively. However, no significant changes were observed in various other parameters, such as anterior and posterior keratometry, refractive status, ACA, ACD, or ACV, at 6 months post-surgery (p > 0.05).Conclusions: Ahmed valve implantation resulted in a significant reduction in axial length. Furthermore, it had transient but non-significant effects on keratometry, refractive status, ACA, ACD, and ACV at 6 months after surgery.","PeriodicalId":17341,"journal":{"name":"Journal of The Korean Ophthalmological Society","volume":null,"pages":null},"PeriodicalIF":0.1000,"publicationDate":"2024-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Alterations in Ocular Biometrics Following Ahmed Valve Implantation\",\"authors\":\"Yunseog Choi, Kyong Jin Cho, Yuli Park\",\"doi\":\"10.3341/jkos.2024.65.2.132\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose: We assessed changes in ocular biometrics following Ahmed valve implantation.Methods: We conducted a retrospective analysis involving 76 eyes of 76 glaucoma patients who underwent Ahmed valve implantation; these patients were followed up for 6 months. Preoperative data, including age, intraocular pressure (IOP), refractive status, axial length, central corneal thickness, anterior chamber depth (ACD), anterior chamber volume (ACV), and anterior and posterior keratometry, were evaluated preoperatively and at 1 week, 1 month, and 6 months postoperatively.Results: The mean IOP exhibited a significant reduction from 39.17 ± 14.06 mmHg preoperatively to 11.43 ± 3.25 mmHg (p < 0.001), 13.18 ± 4.64 mmHg (p < 0.001), and 12.95 ± 4.37 mmHg (p < 0.001) at 1 week, 1 month, and 6 months postoperatively, respectively. Furthermore, the axial length exhibited a significant post-surgery reduction, measuring 23.74 ± 2.01 mm preoperatively and 23.48 ± 1.86 mm (p < 0.001), 23.57 ± 1.94 mm (p < 0.001), and 23.61 ± 1.98 mm (p = 0.002) at 1 week, 1 month, and 6 months postoperatively, respectively. However, no significant changes were observed in various other parameters, such as anterior and posterior keratometry, refractive status, ACA, ACD, or ACV, at 6 months post-surgery (p > 0.05).Conclusions: Ahmed valve implantation resulted in a significant reduction in axial length. Furthermore, it had transient but non-significant effects on keratometry, refractive status, ACA, ACD, and ACV at 6 months after surgery.\",\"PeriodicalId\":17341,\"journal\":{\"name\":\"Journal of The Korean Ophthalmological Society\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.1000,\"publicationDate\":\"2024-02-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of The Korean Ophthalmological Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3341/jkos.2024.65.2.132\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The Korean Ophthalmological Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3341/jkos.2024.65.2.132","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:我们评估了 Ahmed 瓣膜植入术后眼部生物测量的变化:我们对接受艾哈迈德瓣膜植入术的 76 位青光眼患者的 76 只眼睛进行了回顾性分析,并对这些患者进行了 6 个月的随访。术前数据包括年龄、眼压(IOP)、屈光状态、轴向长度、中央角膜厚度、前房深度(ACD)、前房容积(ACV)以及前后角膜测量:平均眼压从术前的 39.17 ± 14.06 mmHg 显著降至术后 1 周、1 个月和 6 个月时的 11.43 ± 3.25 mmHg(p < 0.001)、13.18 ± 4.64 mmHg(p < 0.001)和 12.95 ± 4.37 mmHg(p < 0.001)。此外,轴向长度在术后也有显著减少,术前为 23.74 ± 2.01 毫米,术后 1 周、1 个月和 6 个月时分别为 23.48 ± 1.86 毫米(p < 0.001)、23.57 ± 1.94 毫米(p < 0.001)和 23.61 ± 1.98 毫米(p = 0.002)。然而,术后 6 个月时,前后角膜度数、屈光状态、ACA、ACD 或 ACV 等其他参数均无明显变化(p > 0.05):结论:艾哈迈德瓣膜植入术可显著缩短轴长。结论:Ahmed 瓣膜植入术可明显缩短轴长,而且对术后 6 个月的角膜测量、屈光状态、ACA、ACD 和 ACV 有短暂但不显著的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Alterations in Ocular Biometrics Following Ahmed Valve Implantation
Purpose: We assessed changes in ocular biometrics following Ahmed valve implantation.Methods: We conducted a retrospective analysis involving 76 eyes of 76 glaucoma patients who underwent Ahmed valve implantation; these patients were followed up for 6 months. Preoperative data, including age, intraocular pressure (IOP), refractive status, axial length, central corneal thickness, anterior chamber depth (ACD), anterior chamber volume (ACV), and anterior and posterior keratometry, were evaluated preoperatively and at 1 week, 1 month, and 6 months postoperatively.Results: The mean IOP exhibited a significant reduction from 39.17 ± 14.06 mmHg preoperatively to 11.43 ± 3.25 mmHg (p < 0.001), 13.18 ± 4.64 mmHg (p < 0.001), and 12.95 ± 4.37 mmHg (p < 0.001) at 1 week, 1 month, and 6 months postoperatively, respectively. Furthermore, the axial length exhibited a significant post-surgery reduction, measuring 23.74 ± 2.01 mm preoperatively and 23.48 ± 1.86 mm (p < 0.001), 23.57 ± 1.94 mm (p < 0.001), and 23.61 ± 1.98 mm (p = 0.002) at 1 week, 1 month, and 6 months postoperatively, respectively. However, no significant changes were observed in various other parameters, such as anterior and posterior keratometry, refractive status, ACA, ACD, or ACV, at 6 months post-surgery (p > 0.05).Conclusions: Ahmed valve implantation resulted in a significant reduction in axial length. Furthermore, it had transient but non-significant effects on keratometry, refractive status, ACA, ACD, and ACV at 6 months after surgery.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.20
自引率
0.00%
发文量
126
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信