抽水出口平地流域的 BMP 评估

Rituraj Shukla, R. Rudra, Prasad Daggupati, Colin Little, Alamgir Khan, Pradeep Goel, S. Prasher
{"title":"抽水出口平地流域的 BMP 评估","authors":"Rituraj Shukla, R. Rudra, Prasad Daggupati, Colin Little, Alamgir Khan, Pradeep Goel, S. Prasher","doi":"10.3390/hydrology11020022","DOIUrl":null,"url":null,"abstract":"The effectiveness of existing and potential best management practices (BMPs) to cropped lands in the Jeannette Creek watershed (Thames River basin, Ontario, Canada) in reducing P loads at its pumped outlets was assessed using the Soil and Water Assessment Tool (SWAT). Existing BMPs consisted of banded, incorporated, and variable phosphorus (P)-rate application, conservation tillage, cover crops, and vegetative buffer strips. Potential BMPs consisted of banded P application, no-till, and a cover crop following winter wheat. Two separately delineated sub-watersheds, J1 and J2, characterized by a flat topography and distinct pumped outlets, were selected for analysis. Despite challenges in delineation, the SWAT model was successfully set up to assess the impact of BMPs in reducing P loads in these sub-watersheds. Each BMP was systematically removed, and the resulting simulated P loads were compared with the baseline scenario. Compared to cover crops or vegetative buffer strips, the implementation of conservation tillage and no-till, along with altering the mode of P application, offered superior effectiveness in reducing the P load. On average, the annual reduction in total P (Ptot) loads under existing BMPs was 9.2% in J1 and 11.3% in J2, whereas, under potential BMPs, this reduction exceeded 60% in both watersheds.","PeriodicalId":508746,"journal":{"name":"Hydrology","volume":"129 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of BMPs in Flatland Watershed with Pumped Outlet\",\"authors\":\"Rituraj Shukla, R. Rudra, Prasad Daggupati, Colin Little, Alamgir Khan, Pradeep Goel, S. Prasher\",\"doi\":\"10.3390/hydrology11020022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The effectiveness of existing and potential best management practices (BMPs) to cropped lands in the Jeannette Creek watershed (Thames River basin, Ontario, Canada) in reducing P loads at its pumped outlets was assessed using the Soil and Water Assessment Tool (SWAT). Existing BMPs consisted of banded, incorporated, and variable phosphorus (P)-rate application, conservation tillage, cover crops, and vegetative buffer strips. Potential BMPs consisted of banded P application, no-till, and a cover crop following winter wheat. Two separately delineated sub-watersheds, J1 and J2, characterized by a flat topography and distinct pumped outlets, were selected for analysis. Despite challenges in delineation, the SWAT model was successfully set up to assess the impact of BMPs in reducing P loads in these sub-watersheds. Each BMP was systematically removed, and the resulting simulated P loads were compared with the baseline scenario. Compared to cover crops or vegetative buffer strips, the implementation of conservation tillage and no-till, along with altering the mode of P application, offered superior effectiveness in reducing the P load. On average, the annual reduction in total P (Ptot) loads under existing BMPs was 9.2% in J1 and 11.3% in J2, whereas, under potential BMPs, this reduction exceeded 60% in both watersheds.\",\"PeriodicalId\":508746,\"journal\":{\"name\":\"Hydrology\",\"volume\":\"129 2\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Hydrology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/hydrology11020022\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hydrology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/hydrology11020022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

使用土壤与水评估工具 (SWAT) 评估了 Jeannette 溪流域(加拿大安大略省泰晤士河流域)现有和潜在的最佳管理方法 (BMP) 在减少其抽水口的磷负荷方面的效果。现有的 BMP 包括带状施磷、混合施磷和可变施磷率施磷、保护性耕作、覆盖作物和植被缓冲带。潜在的 BMP 包括带状施磷、免耕和冬小麦后覆盖作物。我们选择了两个分别划定的子流域 J1 和 J2 进行分析,这两个子流域的特点是地形平坦、抽水出口明显。尽管在划界方面存在挑战,但还是成功建立了 SWAT 模型,以评估 BMP 对减少这些子流域 P 负荷的影响。系统地移除了每个 BMP,并将模拟得出的 P 负荷与基线方案进行了比较。与覆盖作物或植被缓冲带相比,实施保护性耕作和免耕以及改变施用磷的模式在减少磷负荷方面具有更高的有效性。平均而言,在现有的 BMP 条件下,J1 和 J2 的总磷(Ptot)负荷年均减少量分别为 9.2% 和 11.3%,而在潜在的 BMP 条件下,这两个流域的总磷(Ptot)负荷年均减少量均超过 60%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of BMPs in Flatland Watershed with Pumped Outlet
The effectiveness of existing and potential best management practices (BMPs) to cropped lands in the Jeannette Creek watershed (Thames River basin, Ontario, Canada) in reducing P loads at its pumped outlets was assessed using the Soil and Water Assessment Tool (SWAT). Existing BMPs consisted of banded, incorporated, and variable phosphorus (P)-rate application, conservation tillage, cover crops, and vegetative buffer strips. Potential BMPs consisted of banded P application, no-till, and a cover crop following winter wheat. Two separately delineated sub-watersheds, J1 and J2, characterized by a flat topography and distinct pumped outlets, were selected for analysis. Despite challenges in delineation, the SWAT model was successfully set up to assess the impact of BMPs in reducing P loads in these sub-watersheds. Each BMP was systematically removed, and the resulting simulated P loads were compared with the baseline scenario. Compared to cover crops or vegetative buffer strips, the implementation of conservation tillage and no-till, along with altering the mode of P application, offered superior effectiveness in reducing the P load. On average, the annual reduction in total P (Ptot) loads under existing BMPs was 9.2% in J1 and 11.3% in J2, whereas, under potential BMPs, this reduction exceeded 60% in both watersheds.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信