关于动物膀胱测量中的变异性和检测不可靠的测量结果

Zachary C. Danziger, Daniel Jaskowak
{"title":"关于动物膀胱测量中的变异性和检测不可靠的测量结果","authors":"Zachary C. Danziger, Daniel Jaskowak","doi":"10.3389/fruro.2024.1348002","DOIUrl":null,"url":null,"abstract":"Animal cystometry, a process of infusing fluid into the urinary bladder to evoke reflex contractions, is a common way to study the effects of pathology, injury, or experimental therapy on lower urinary tract (LUT) dynamics. By monitoring fluid movement during the cystometric micturition cycle, one can compute important quantities that indicate the health and function of the LUT, such as bladder capacity and voiding efficiency. Unfortunately, volume measurements in these difficult studies are often unpreventably corrupted by noise, leading to uncertainty when estimating key cystometric parameters.This work proposes a criterion, based on measurable quantities, that flags micturition cycles in cystometry studies that are likely to contain large measurement errors, potentially allowing experimenters to remove them from analysis to obtain a more accurate summary of LUT dynamics.We describe the criterion, validate it against experimental data, and use computer simulations to demonstrate its utility.","PeriodicalId":73113,"journal":{"name":"Frontiers in urology","volume":"64 12","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"On variability and detecting unreliable measurements in animal cystometry\",\"authors\":\"Zachary C. Danziger, Daniel Jaskowak\",\"doi\":\"10.3389/fruro.2024.1348002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Animal cystometry, a process of infusing fluid into the urinary bladder to evoke reflex contractions, is a common way to study the effects of pathology, injury, or experimental therapy on lower urinary tract (LUT) dynamics. By monitoring fluid movement during the cystometric micturition cycle, one can compute important quantities that indicate the health and function of the LUT, such as bladder capacity and voiding efficiency. Unfortunately, volume measurements in these difficult studies are often unpreventably corrupted by noise, leading to uncertainty when estimating key cystometric parameters.This work proposes a criterion, based on measurable quantities, that flags micturition cycles in cystometry studies that are likely to contain large measurement errors, potentially allowing experimenters to remove them from analysis to obtain a more accurate summary of LUT dynamics.We describe the criterion, validate it against experimental data, and use computer simulations to demonstrate its utility.\",\"PeriodicalId\":73113,\"journal\":{\"name\":\"Frontiers in urology\",\"volume\":\"64 12\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Frontiers in urology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3389/fruro.2024.1348002\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in urology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/fruro.2024.1348002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

动物膀胱测定法是将液体注入膀胱以诱发反射性收缩的过程,是研究病理、损伤或实验疗法对下尿路(LUT)动态影响的常用方法。通过监测膀胱排尿周期中的液体运动,可以计算出显示下尿路健康和功能的重要数据,如膀胱容量和排尿效率。不幸的是,在这些困难的研究中,排尿量的测量往往会不可避免地受到噪声的干扰,从而导致在估算关键膀胱测量参数时出现不确定性。这项研究提出了一种基于可测量量的标准,该标准可在膀胱测量研究中标出可能存在较大测量误差的排尿周期,从而使实验人员能够将其从分析中剔除,以获得更准确的 LUT 动态概要。我们对该标准进行了描述,根据实验数据对其进行了验证,并使用计算机模拟来证明其实用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
On variability and detecting unreliable measurements in animal cystometry
Animal cystometry, a process of infusing fluid into the urinary bladder to evoke reflex contractions, is a common way to study the effects of pathology, injury, or experimental therapy on lower urinary tract (LUT) dynamics. By monitoring fluid movement during the cystometric micturition cycle, one can compute important quantities that indicate the health and function of the LUT, such as bladder capacity and voiding efficiency. Unfortunately, volume measurements in these difficult studies are often unpreventably corrupted by noise, leading to uncertainty when estimating key cystometric parameters.This work proposes a criterion, based on measurable quantities, that flags micturition cycles in cystometry studies that are likely to contain large measurement errors, potentially allowing experimenters to remove them from analysis to obtain a more accurate summary of LUT dynamics.We describe the criterion, validate it against experimental data, and use computer simulations to demonstrate its utility.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信