{"title":"移动式通用灭火系统的消防测试","authors":"Maxim Sytdykov, Alexander Shilov, Dmitry Brusyanin","doi":"10.61260/1998-8990-2024-2023-4-175-184","DOIUrl":null,"url":null,"abstract":"To assess the effectiveness of a full-size mobile universal fire extinguishing system, fire tests of the developed layout of an experimental mobile universal fire extinguishing system were carried out, taking into account the requirements of national standards, which determined the choice of the operating pressure range and nozzle diameters. Numerical values of the duration of the supply, the length of the jet and the rate of discharge of fire extinguishing agent from the vessel of the layout of a mobile universal fire extinguishing system from the diameters of the nozzles with a change in pressure are obtained. The results showed that \nthe duration of the supply and the length of the jet of fire extinguishing agent, regardless of the diameters of the nozzles, depend on the pressure, the flow rate and outflow rate of fire extinguishing agent depend on both the diameters of the nozzles and the pressure. The relationship between the parameters of the layout and its extinguishing capacity has been determined, which confirms the declared capabilities of its working cycle.","PeriodicalId":497475,"journal":{"name":"Problems of risk management in the technosphere","volume":"12 4","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"FIRE TESTS OF A MOBILE UNIVERSAL FIRE EXTINGUISHING SYSTEM\",\"authors\":\"Maxim Sytdykov, Alexander Shilov, Dmitry Brusyanin\",\"doi\":\"10.61260/1998-8990-2024-2023-4-175-184\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To assess the effectiveness of a full-size mobile universal fire extinguishing system, fire tests of the developed layout of an experimental mobile universal fire extinguishing system were carried out, taking into account the requirements of national standards, which determined the choice of the operating pressure range and nozzle diameters. Numerical values of the duration of the supply, the length of the jet and the rate of discharge of fire extinguishing agent from the vessel of the layout of a mobile universal fire extinguishing system from the diameters of the nozzles with a change in pressure are obtained. The results showed that \\nthe duration of the supply and the length of the jet of fire extinguishing agent, regardless of the diameters of the nozzles, depend on the pressure, the flow rate and outflow rate of fire extinguishing agent depend on both the diameters of the nozzles and the pressure. The relationship between the parameters of the layout and its extinguishing capacity has been determined, which confirms the declared capabilities of its working cycle.\",\"PeriodicalId\":497475,\"journal\":{\"name\":\"Problems of risk management in the technosphere\",\"volume\":\"12 4\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Problems of risk management in the technosphere\",\"FirstCategoryId\":\"0\",\"ListUrlMain\":\"https://doi.org/10.61260/1998-8990-2024-2023-4-175-184\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Problems of risk management in the technosphere","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.61260/1998-8990-2024-2023-4-175-184","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了评估全尺寸移动式通用灭火系统的有效性,对已开发的实验性移动式通用灭火系统布局进行了灭火测试,测试中考虑了国家标准的要求,这些要求决定了工作压力范围和喷嘴直径的选择。根据压力变化时喷嘴直径的变化,获得了从移动式通用灭火系统布局的容器中喷射灭火剂的持续时间、喷射长度和排放速率的数值。结果表明,无论喷嘴的直径如何,灭火剂喷射的持续时间和长度都取决于压力,灭火剂的流量和流出率既取决于喷嘴的直径,也取决于压力。已经确定了布局参数与其灭火能力之间的关系,这证实了其工作周期的申报能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
FIRE TESTS OF A MOBILE UNIVERSAL FIRE EXTINGUISHING SYSTEM
To assess the effectiveness of a full-size mobile universal fire extinguishing system, fire tests of the developed layout of an experimental mobile universal fire extinguishing system were carried out, taking into account the requirements of national standards, which determined the choice of the operating pressure range and nozzle diameters. Numerical values of the duration of the supply, the length of the jet and the rate of discharge of fire extinguishing agent from the vessel of the layout of a mobile universal fire extinguishing system from the diameters of the nozzles with a change in pressure are obtained. The results showed that the duration of the supply and the length of the jet of fire extinguishing agent, regardless of the diameters of the nozzles, depend on the pressure, the flow rate and outflow rate of fire extinguishing agent depend on both the diameters of the nozzles and the pressure. The relationship between the parameters of the layout and its extinguishing capacity has been determined, which confirms the declared capabilities of its working cycle.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信